Intra-aneurysmal hemodynamics in a large middle cerebral artery aneurysm with wall atherosclerosis

被引:15
|
作者
Tateshima, Satoshi [1 ,2 ]
Tanishita, Kazuo [3 ]
Omura, Hiroyoshi [3 ]
Sayre, James [5 ]
Villablanca, J. Pablo [2 ,4 ]
Martin, Neil [2 ,6 ]
Vinuela, Fernando [2 ]
机构
[1] Univ Calif Los Angeles, Med Ctr, Dept Radiol Sci, Div Intervent Neuroradiol, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[3] Keio Univ, Fac Sci & Technol, Dept Syst Design Engn, Yokohama, Kanagawa 2235522, Japan
[4] Univ Calif Los Angeles, Div Diagnost Neuroradiol, Med Ctr, Los Angeles, CA 90095 USA
[5] Univ Calif Los Angeles, Los Angeles Sch Publ Hlth, Dept Biostat, Los Angeles, CA 90095 USA
[6] Univ Calif Los Angeles, Med Ctr, Div Neurosurg, Los Angeles, CA 90095 USA
来源
SURGICAL NEUROLOGY | 2008年 / 70卷 / 05期
关键词
Hemodynamics; Atherosclerosis; Remodeling; Cerebral aneurysm; Wall shear stress;
D O I
10.1016/j.surneu.2008.03.035
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: The remodeling of arterial extra-cellular matrix induced by hemodynamic stimuli is involved in the process of atherosclerosis in the carotid and cerebral arteries. Scarce information is available on the relationship between atherosclerotic changes in brain aneurysms itself and its intra-aneurysmal hemodynamics. Methods: Surgical exploration of a large MCA aneurysm depicted extensive atherosclerotic changes. in the aneurysm wall. Computational tomographic angiography of this aneurysm was used to create an in vitro aneurysm model. This model was used to perform intra-aneurysmal flow measurement using particle imaging velocimetry and LDV. Intra-aneurysmal hemodynamic pattern with wall shear stress distribution was compared between areas with and without atherosclerotic changes. Results: No high oscillation of wall shear stress was observed on the atherosclerotic plaque area. However, the magnitude of wall shear stress tended to be higher in the area without atherosclerotic changes than the area with those changes (P<.001). There was no atherosclerotic change at the aneurysm inflow zone, where relatively fast flow velocity and higher magnitude of wall shear stress was noted. Conclusions: This single case of atherosclerosis in an aneurysm shows some similarity in hemodynamic values observed in cases of carotid atherosclerotic plaques. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:454 / 462
页数:9
相关论文
共 50 条
  • [31] Fatal rupture following intra-aneurysmal embolization for the distal posterior inferior cerebellar artery aneurysm with parent artery preservation
    Fujimura, M
    Nishijima, M
    Midorikawa, H
    Umezawa, K
    Hayashi, T
    Kaimori, M
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2003, 105 (02) : 117 - 120
  • [32] Endovascular Aneurysm Repair of Acute Occlusion of Abdominal Aortic Aneurysm with Intra-Aneurysmal Dissection
    Terai, Yasuhiko
    Mitsuoka, Hiroshi
    Nakai, Masanao
    Goto, Shinnosuke
    Miyano, Yuta
    Tsuchiya, Hirokazu
    Yamazaki, Fumio
    ANNALS OF VASCULAR SURGERY, 2015, 29 (08) : 1658.e11 - 1658.e14
  • [33] Influence of stent properties on the alteration of cerebral intra-aneurysmal haemodynamics:: flow quantification in elastic sidewall aneurysm models
    Baráth, K
    Cassot, F
    Fasel, JHD
    Ohta, M
    Rüfenacht, DA
    NEUROLOGICAL RESEARCH, 2005, 27 : S120 - S128
  • [34] How Do Coil Configuration and Packing Density Influence Intra-Aneurysmal Hemodynamics?
    Morales, H. G.
    Kim, M.
    Vivas, E. E.
    Villa-Uriol, M. -C.
    Larrabide, I.
    Sola, T.
    Guimaraens, L.
    Frangi, A. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1935 - 1941
  • [35] A case of unruptured cerebral aneurysm treated by intra-aneurysmal embolization during outpatient hemodialysis for chronic renal failure
    Nakajima, T
    Ezura, M
    Takahashi, A
    Yoshimoto, T
    NEUROLOGICAL SURGERY, 1999, 27 (03): : 255 - 259
  • [36] Variations of Middle Cerebral Artery Hemodynamics Due to Aneurysm Clipping Surgery
    Davidson, Haleigh
    Scardino, Brooke
    Gamage, Peshala Thibbotuwawa
    Taebi, Amirtahà
    Journal of Engineering and Science in Medical Diagnostics and Therapy, 2024, 71 (01)
  • [37] Intra-aneurysmal embolization for the treatment of cerebral aneurysms using detachable coils
    Hyodo, A
    Kato, N
    Anno, I
    Sato, H
    Nose, T
    Okazaki, M
    Kamezaki, T
    Ito, M
    INTERVENTIONAL NEURORADIOLOGY, 1998, 4 : 67 - 69
  • [38] Determining intra-aneurysmal flow for coiled cerebral aneurysms with digital fluoroscopy
    Jou, Liang-Der
    Saloner, David
    Higashida, Randall
    Biomed. Eng. Appl. Basis Commun., 1600, 2 (43-48):
  • [39] Stretchable, Implantable, Nanostructured Flow-Diverter System for Quantification of Intra-aneurysmal Hemodynamics
    Howe, Connor
    Mishra, Saswat
    Kim, Yun-Soung
    Chen, Yanfei
    Ye, Sang-Ho
    Wagner, William R.
    Jeong, Jae-Woong
    Byun, Hun-Soo
    Kim, Jong-Hoon
    Chun, Youngjae
    Yeo, Woon-Hong
    ACS NANO, 2018, 12 (08) : 8706 - 8716
  • [40] Additional Value of Intra-Aneurysmal Hemodynamics in Discriminating Ruptured versus Unruptured Intracranial Aneurysms
    Schneiders, J. J.
    Marquering, H. A.
    van Ooij, P.
    van den Berg, R.
    Nederveen, A. J.
    Verbaan, D.
    Vandertop, W. P.
    Pourquie, M.
    Rinkel, G. J. E.
    vanBavel, E.
    Majoie, C. B. L. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (10) : 1920 - 1926