The antinuclear antibody HEp-2 indirect immunofluorescence assay: a survey of laboratory performance, pattern recognition and interpretation

被引:10
|
作者
Tebo, Anne E. [1 ,2 ]
Schmidt, Robert L. [1 ,2 ]
Kadkhoda, Kamran [3 ]
Peterson, Lisa K. [1 ,2 ]
Chan, Edward K. L. [4 ]
Fritzler, Marvin J. [5 ]
Wener, Mark H. [6 ,7 ]
机构
[1] Univ Utah, Dept Pathol, Salt Lake City, UT 84112 USA
[2] ARUP Inst Clin & Expt Pathol, Salt Lake City, UT USA
[3] Cleveland Clin, Robert J Tomsich Pathol & Lab Med Inst, Immunopathol Lab, Cleveland, OH 44106 USA
[4] Univ Florida, Dept Oral Biol, Gainesville, FL 32610 USA
[5] Univ Calgary, Cumming Sch Med, Dept Med, Calgary, AB, Canada
[6] Univ Washington, Dept Lab Med & Pathol, Seattle, WA 98195 USA
[7] Univ Washington, Dept Med, Seattle, WA USA
关键词
Anti-nuclear antibodies; Cytoplasmic patterns; Performance survey; Indirect immunofluorescence; Mitotic patterns; Nuclear patterns;
D O I
10.1186/s13317-020-00146-w
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background To evaluate the interpretation and reporting of antinuclear antibodies (ANA) by indirect immunofluorescence assay (IFA) using HEp-2 substrates based on common practice and guidance by the International Consensus on ANA patterns (ICAP). Method Participants included two groups [16 clinical laboratories (CL) and 8 in vitro diagnostic manufacturers (IVD)] recruited via an email sent to the Association of Medical Laboratory Immunologists (AMLI) membership. Twelve (n = 12) pre-qualified specimens were distributed to participants for testing, interpretation and reporting HEp-2 IFA. Results obtained were analyzed for accuracy with the intended and consensus response for three main categorical patterns (nuclear, cytoplasmic and mitotic), common patterns and ICAP report nomenclatures. The distributions of antibody titers of specimens were also compared. Results Laboratories differed in the categorical patterns reported; 8 reporting all patterns, 3 reporting only nuclear patterns and 5 reporting nuclear patterns with various combinations of other patterns. For all participants, accuracy with the intended response for the categorical nuclear pattern was excellent at 99% [95% confidence interval (CI): 97-100%] compared to 78% [95% CI 67-88%] for the cytoplasmic, and 93% [95% CI 86%-100%] for mitotic patterns. The accuracy was 13% greater for the common nomenclature [87%, 95% CI 82-90%] compared to the ICAP nomenclature [74%, 95% CI 68-79%] for all participants. Participants reporting all three main categories demonstrated better performances compared to those reporting 2 or less categorical patterns. The average accuracies varied between participant groups, however, with the lowest and most variable performances for cytoplasmic pattern specimens. The reported titers for all specimens varied, with the least variability for nuclear patterns and most titer variability associated with cytoplasmic patterns. Conclusions Our study demonstrated significant accuracy for all participants in identifying the categorical nuclear staining as well as traditional pattern assignments for nuclear patterns. However, there was less consistency in reporting cytoplasmic and mitotic patterns, with implications for assigning competencies and training for clinical laboratory personnel.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Standardization of autoantibody detection using indirect immunofluorescence on HEp-2 cells
    von Landenberg, P.
    ALLERGOLOGIE, 2011, 34 (02) : 79 - 79
  • [32] Clinical description of patients with cytoplasmic discrete dots pattern (lysosome) on indirect immunofluorescence on HEp-2 cells
    Brom, Martin
    Carrizo, Carolina Eva
    Arana, Roberto Miguel
    Pisoni, Cecilia Nora
    CLINICAL RHEUMATOLOGY, 2018, 37 (12) : 3435 - 3437
  • [33] New automated indirect immunofluorescent antinuclear antibody testing compares well with established manual immunofluorescent screening and titration for antinuclear antibody on HEp-2 cells
    Daves, M.
    Blecken, J.
    Matthias, T.
    Frey, A.
    Perkmann, V.
    Acqua, A. Dali
    Joos, A.
    Platzgummer, S.
    IMMUNOLOGIC RESEARCH, 2017, 65 (01) : 370 - 374
  • [34] Automated Versus Conventional Microscopic Interpretation of Antinuclear Antibody Indirect Immunofluorescence Test
    Park, Yumi
    Kim, Seon Young
    Kwon, Gye Cheol
    Koo, Sun Hoe
    Kang, Eun-Suk
    Kim, Jimyung
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2019, 49 (01): : 127 - 133
  • [35] Clinical description of patients with cytoplasmic discrete dots pattern (lysosome) on indirect immunofluorescence on HEp-2 cells
    Martin Brom
    Carolina Eva Carrizo
    Roberto Miguel Arana
    Cecilia Nora Pisoni
    Clinical Rheumatology, 2018, 37 : 3435 - 3437
  • [36] Evaluation of a Fully Automated Antinuclear Antibody Indirect Immunofluorescence Assay in Routine Use
    Choi, Hyun-Woo
    Kwon, Yong Jun
    Park, Ju-Heon
    Lee, Seung-Yeob
    Chun, Sejong
    Won, Eun Jeong
    Lee, Jun Hyung
    Choi, Hyun-Jung
    Kim, Soo Hyun
    Shin, Myung-Geun
    Shin, Jong-Hee
    Kee, Seung-Jung
    FRONTIERS IN IMMUNOLOGY, 2020, 11
  • [37] Assessment of antinuclear antibodies by indirect immunofluorescence assay: report from a survey by the American Association of Medical Laboratory Immunologists
    Peterson, Lisa K.
    Tebo, Anne E.
    Wener, Mark H.
    Copple, Susan S.
    Fritzler, Marvin J.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (09) : 1489 - 1497
  • [38] Harmonization of clinical interpretation of antinuclear antibody test results by solid phase assay and by indirect immunofluorescence through likelihood ratios
    Bossuyt, Xavier
    Claessens, Jolien
    Belmondo, Thibaut
    De Langhe, Ellen
    Westhovens, Rene
    Poesen, Koen
    Hue, Sophie
    Blockmans, Daniel
    Fritzler, Marvin J.
    Mahler, Michael
    Fierz, Walter
    AUTOIMMUNITY REVIEWS, 2019, 18 (11)
  • [39] Exposure of HEp-2 cells to stress conditions influences antinuclear antibody reactivity
    Du, LP
    Fukushima, S
    Sallmyr, A
    Manthorpe, R
    Bredberg, A
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2002, 9 (02) : 287 - 294
  • [40] An automated approach to the segmentation of HEp-2 cells for the indirect immunofluorescence ANA test
    Tonti, Simone
    Di Cataldo, Santa
    Bottino, Andrea
    Ficarra, Elisa
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 40 : 62 - 69