Two-dimensional echocardiographic measures of left ventricular dimensions agree with M-mode measurements in dogs

被引:2
|
作者
Rishniw, M. [1 ,2 ]
Corda, A. [3 ]
Spina, F. [4 ]
Caivano, D. [5 ]
机构
[1] Cornell Univ, Coll Vet Med, Dept Clin Sci, Ithaca, NY 14853 USA
[2] Vet Informat Network, Davis, CA 95616 USA
[3] Univ Sassari, Dept Vet Med, Via Vienna 2, I-07100 Sassari, Italy
[4] Vet Hosp Etiopia, Rome, Italy
[5] Univ Perugia, Dept Vet Med, Via San Costanzo 4, I-06126 Perugia, Italy
关键词
Canine; Echocardiography; Cardiac mensuration; Cardiomegaly;
D O I
10.1016/j.jvc.2020.12.001
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Introduction: Clinicians measure left ventricular dimensions in dogs from both M-mode and two-dimensional images. Little information currently exists as to whether these two methods provide measurements similar enough to be interchangeable. Animals: The animals included in this study are 206 client-owned dogs: 68 healthy, 105 with myxomatous mitral valve disease, 33 with other cardiac or extracardiac disease. Materials and methods: Investigators measured left ventricular diastolic and systolic dimensions from archived M-mode and two-dimensional images obtained from the right parasternal short-axis view. Agreement between the pairs of measure-ments was examined using limits of agreement (Bland-Altman) plots. Results: Left ventricular diastolic dimensions showed no fixed or proportional bias but did show heteroscedasticity. Ninety-five percent limits of agreement for normalized differences approximated +/- 10%; 95% of the absolute differences for any pair of measurements were <3.9 mm regardless of bodyweight and <2.7 mm for dogs <15 kg. Left ventricular systolic dimensions showed slight proportional bias, with two-dimensional measurements being progressively larger than M-mode measurements as ventricular size increased. Ninety-five percent limits of agree-ment for normalized differences approximated +/- 20%; 95% of the absolute differ-ences for any pair of measurements were <4.6 mm regardless of bodyweight and <3.5 mm for dogs <15 kg. Mitral valve disease did not appreciably affect these find-ings. Conclusions: Left ventricular internal dimensions in dogs with and without cardiac disease measured from two-dimensional right parasternal short-axis images are in-terchangeable with those measured from M-mode images using the same view. (C) 2020 Published by Elsevier B.V.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 50 条
  • [31] Assessment of left ventricular mass in mice: Comparison between two-dimensional and M-mode echocardiography
    Kiatchoosakun, S
    Restivo, J
    Kirkpatrick, D
    Hoit, BD
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2002, 19 (03): : 199 - 205
  • [32] Effects of animal position on M-mode, two-dimensional, and Doppler echocardiographic measurements in healthy French bulldogs
    Bagardi, Mara
    Ghilardi, Sara
    Locatelli, Chiara
    Romussi, Stefano
    Brambilla, Paola G.
    VETERINARY RADIOLOGY & ULTRASOUND, 2023, 64 (04) : 758 - 767
  • [33] Comparison of two-dimensional echocardiographic measurements of the left atrium in healthy dogs
    Hetyey, C
    Vörös, K
    Reiczigel, J
    ACTA VETERINARIA HUNGARICA, 2005, 53 (01) : 23 - 33
  • [34] TWO-DIMENSIONAL ECHOCARDIOGRAPHIC MEASUREMENTS OF THE LEFT ATRIUM IN DOGS WITH CARDIAC DISEASE
    Dudas-Gyorki, Zoltan
    Bende, Boglarka
    Hetyey, Csaba
    Manczur, Ferenc
    Reiczigel, Jeno
    Voros, Karoly
    ACTA VETERINARIA HUNGARICA, 2009, 57 (02) : 203 - 215
  • [35] M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC DIAGNOSIS OF ATRIAL SEPTAL-DEFECT
    CALABRO, MP
    RIVISTA ITALIANA DI PEDIATRIA-ITALIAN JOURNAL OF PEDIATRICS, 1982, 8 (06): : 853 - 854
  • [36] M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC ABNORMALITIES IN SYSTEMIC LUPUS-ERYTHEMATOSUS
    KLINKHOFF, AV
    THOMPSON, CR
    REID, GD
    TOMLINSON, CW
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1985, 253 (22): : 3273 - 3277
  • [37] ECHOCARDIOGRAPHIC DIAGNOSIS OF AORTIC ROOT DISSECTION BY M-MODE AND TWO-DIMENSIONAL TECHNIQUES
    SMUCKLER, AL
    NOMEIR, AM
    WATTS, LE
    HACKSHAW, BT
    AMERICAN HEART JOURNAL, 1982, 103 (05) : 897 - 904
  • [38] PRIMARY PULMONARY-HYPERTENSION - M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC FINDINGS
    BERGER, BC
    WALINSKY, P
    CAREY, P
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1983, 9 (02): : 187 - 195
  • [39] MITRAL-VALVE ANEURYSM - M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC FEATURES
    OQUENDO, I
    NAVA, J
    HERNANDEZCASAS, G
    SULBARAN, T
    GARCIA, L
    TEXAS HEART INSTITUTE JOURNAL, 1987, 14 (03) : 312 - 314
  • [40] TWO-DIMENSIONAL AND M-MODE ECHOCARDIOGRAPHIC FINDINGS IN HYPERTENSIVE PREGNANT-WOMEN
    SANCHEZ, RA
    GLENNY, JE
    MARCO, E
    VOTO, LS
    LAPIDUS, AM
    IGLESIAS, GH
    MOLEDO, LV
    MARGULIES, M
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1986, 154 (04) : 910 - 913