The Hypointense Liver Lesion on T2-Weighted MR Images and What It Means

被引:16
|
作者
Curvo-Semedo, Luis [1 ]
Brito, Jorge B. [1 ]
Seco, Miguel F. [1 ]
Costa, Joao F. [1 ]
Marques, Cristina B. [1 ]
Caseiro-Alves, Filipe [1 ]
机构
[1] Coimbra Univ Hosp, Dept Radiol, P-3000075 Coimbra, Portugal
关键词
FOCAL NODULAR HYPERPLASIA; SMALL HEPATOCELLULAR-CARCINOMA; REGENERATIVE NODULES; ETHANOL INJECTION; IMAGING FINDINGS; COPPER CONTENT; IRON; CT; INVOLVEMENT; FERRITIN;
D O I
10.1148/rg.e38
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The vast majority of focal liver lesions are hyperintense on T2-weighted magnetic resonance (MR) images. Rarely, however, hepatic nodules may appear totally or partially hypointense on those images. Causes for this uncommon appearance include deposition of iron, calcium, or copper and are related to the presence of blood degradation products, macromolecules, coagulative necrosis, and other conditions. Although rare, low signal intensity relative to surrounding liver on T2-weighted images may be seen in a wide spectrum of lesions. Examples include cases of focal nodular hyperplasia, hepatocellular adenoma, hepatocellular carcinoma, metastases, leyomioma, siderotic or dysplastic nodules, nodules in Wilson disease, granuloma, and hydatid cyst. On fat-suppressed T2-weighted images, nodules with a lipomatous component, such as lipoma, angiomyolipoma, hepatocellular adenoma, and hepatocellular carcinoma may also appear partially or totally hypointense. The conjunction of other MR imaging findings and their integration in the clinical setting may allow a correct diagnosis in a considerable proportion of cases. The cause for T2-weighted hypointensity may not be, however, always recognized, and only pathologic correlation may provide the answer. The aims of this work are to discuss the causes and mechanisms of hypointensity of liver lesions on T2-weighted images and proposing an algorithm for classification that may be useful as a quick reminder for the interested reader.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] Arterioportal shunts mimicking hepatic tumors with hyperintensity on T2-weighted MR images
    Matsuo, M
    Kanematsu, M
    Kondo, H
    Maeda, S
    Goshima, S
    Suenaga, I
    Hoshi, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (03) : 330 - 333
  • [22] Automatic Location of the Talairach Cortical Landmarks from T2-weighted MR Images
    Fu, Yili
    Zhang, GuangCai
    Chang, Qiuyue
    Wang, Shuguo
    Han, Xianwei
    MATERIALS, MECHATRONICS AND AUTOMATION, PTS 1-3, 2011, 467-469 : 629 - 634
  • [24] Vacuum disc: frequency of high signal intensity on T2-weighted MR images
    M. E. Schweitzer
    K. I. El-Noueam
    Skeletal Radiology, 1998, 27 : 83 - 86
  • [25] Combining T2-weighted with dynamic MR images for computerized classification of prostate lesions
    Vos, Pieter C.
    Hambrock, Thomas
    Barentsz, Jelle O.
    Huisman, Henkjan J.
    MEDICAL IMAGING 2008: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2008, 6915
  • [26] A comparison between segmentation algorithms for urinary bladder on T2-weighted MR images
    Ma, Zhen
    Jorge, Renato Natal
    Tavares, Joao Manuel R. S.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING: VIPIMAGE 2011, 2012, : 371 - 376
  • [27] Computer Aided Detection of Cavernous Malformation in T2-weighted Brain MR Images
    Wang, Huiquan
    Xu, Hongming
    Ahmed, S. Nizam
    Mandal, Mrinal
    2016 IEEE HEALTHCARE INNOVATION POINT-OF-CARE TECHNOLOGIES CONFERENCE (HI-POCT), 2016, : 101 - 104
  • [28] Vacuum disc: frequency of high signal intensity on T2-weighted MR images
    Schweitzer, ME
    El-Noueam, KI
    SKELETAL RADIOLOGY, 1998, 27 (02) : 83 - 86
  • [29] MR of Toxoplasma encephalitis: Signal characteristics on T2-weighted images and pathologic correlation
    Brightbill, TC
    Post, MJD
    Hensley, GT
    Ruiz, A
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (03) : 417 - 422
  • [30] MR IMAGING OF BRAIN METASTASES (1)T2-WEIGHTED IMAGES AS A SCREENING SEQUENCE
    HOSTEN, N
    SCHORNER, W
    SCHUBEUS, P
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 153 (03): : 321 - 326