Coextensive synchronized SLO-OCT with adaptive optics for human retinal imaging

被引:21
|
作者
Azimipour, Mehdi [1 ]
Jonnal, Ravi S. [1 ]
Werner, John S. [1 ]
Zawadzki, Robert J. [1 ,2 ]
机构
[1] UC Davis Eye Ctr, Dept Ophthalmol & Vis Sci, Vis Sci & Adv Retinal Imaging Lab VSRI, Sacramento, CA 95817 USA
[2] Univ Calif Davis, Dept Cell Biol & Human Anat, EyePod Small Anim Ocular Imaging Lab, Davis, CA 95616 USA
关键词
COHERENCE TOMOGRAPHY; HIGH-RESOLUTION; SYSTEM;
D O I
10.1364/OL.44.004219
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We describe the details of a multimodal retinal imaging system which combines adaptive optics (AO) with an integrated scanning light ophthalmoscopy (SLO) and optical coherence tomography (OCT) imaging system. The OCT subsystem consisted of a swept-source, Fourier-domain mode-locked (FDML) laser, with a very high A-scan rate (1.6 MHz), whose beam was raster scanned on the retina by two scanners-one resonant scanner and one galvanometer. The high sweep rate of the FDML permitted the SLO and OCT to utilize the same scanners for in vivo retinal imaging and, unlike existing multimodal systems, concurrently acquired SLO frames and OCT volumes with approximate en face correspondence at a rate of 6 Hz. The AO provided diffraction-limited cellular resolution for both imaging channels. (C) 2019 Optical Society of America
引用
收藏
页码:4219 / 4222
页数:4
相关论文
共 50 条
  • [21] Adaptive optics and retinal imaging
    Roorda, A
    Williams, DR
    VISION SCIENCE AND ITS APPLICATIONS, PROCEEDINGS, 2000, 35 : 151 - 162
  • [22] Retinal imaging with adaptive optics
    Le Gargasson, JF
    Glanc, M
    Léna, P
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE IV PHYSIQUE ASTROPHYSIQUE, 2001, 2 (08): : 1131 - 1138
  • [23] Unsupervised registration of Adaptive Optics retinal images in SLO fundus images
    Fezzani, Riadh
    Cornic, Philippe
    Odlund, Erika Boyenga
    Plyer, Aurelien
    Le Besnerais, Guy
    Kulcsar, Caroline
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [24] Adaptive-optics SLO imaging combined with widefield OCT and SLO enables precise 3D localization of fluorescent cells in the mouse retina
    Zawadzki, Robert J.
    Zhang, Pengfei
    Zam, Azhar
    Miller, Eric B.
    Goswami, Mayank
    Wang, Xinlei
    Jonnal, Ravi S.
    Lee, Sang-Hyuck
    Kim, Dae Yu
    Flannery, John G.
    Werner, John S.
    Burns, Marie E.
    Pugh, Edward N., Jr.
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (06): : 2191 - 2210
  • [25] A 3.4-mm beam diameter system for retinal imaging with OCT and adaptive optics
    Reddikumar, Maddipatla
    Cense, Barry
    BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2017, 10251
  • [26] A 2.8-mm beam diameter system for retinal imaging with OCT and adaptive optics
    Reddikumar, Maddipatla
    Cervantes, Joel
    Otani, Yukitoshi
    Cense, Barry
    BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2018, 10711
  • [27] Adaptive Optics OCT using 1060nm swept source and dual deformable lenses for human retinal imaging
    Jian, Yifan
    Lee, Sujin
    Cua, Michelle
    Miao, Dongkai
    Bonora, Stefano
    Zawadzki, Robert J.
    Sarunic, Marinko V.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697
  • [28] Direct comparison of photoreceptor reflectivity measurements using simultaneous adaptive optics SLO and OCT
    Bower, Andrew
    Liu, Tao
    Liu, Zhuolin
    Aguilera, Nancy
    Li, Joanne
    Lu, Rongwen
    Giannini, John
    Cornelissen, Steven
    Dubra, Alfredo
    Hammer, Daniel
    Tam, Johnny
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [29] Adaptive optics imaging of retinal vasculitis
    Errera, M. H.
    Paques, M.
    ACTA OPHTHALMOLOGICA, 2013, 91
  • [30] Retinal microvascular imaging with adaptive optics
    Kalitzeos, A.
    ACTA OPHTHALMOLOGICA, 2017, 95