Square wave voltammetric determination of diquat using natural phosphate modified platinum electrode

被引:9
|
作者
El Harmoudi, H. [1 ,2 ]
Achak, M. [1 ,2 ]
Lahrich, S. [1 ]
Farahi, A. [1 ,2 ]
El Gaini, L. [2 ]
Bakasse, M. [2 ]
El Mhammedi, M. A. [1 ]
机构
[1] Univ Chouaib Doukkali, Fac Sci, Equipe Anal Micropolluants Organ, El Jadida, Morocco
[2] Univ Hassan 1er, Fac Polydisciplinaire, Equipe Chim Analyt & Modelisat Stat, BP 145, Khouribga, Morocco
关键词
Platinum electrode; Natural phosphate; Diquat; Square wave voltammetry; CARBON-PASTE ELECTRODE; CHEMICALLY-MODIFIED ELECTRODES; LIQUID-CHROMATOGRAPHY; OLIVE OIL; PARAQUAT; EXTRACTION; SAMPLES; WATER; ACID;
D O I
10.1016/j.arabjc.2012.11.007
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A platinum electrode modified with natural phosphate (NP) was evaluated as an electro-chemical sensor for diquat (DQ) in aqueous medium. The electrode was prepared by the deposition of natural phosphate on the platinum surface. Diquat was preconcentrated on the surface of the modified electrode by adsorbing with natural phosphate and reduced at a negative potential in 0.1 M K2SO4 solution. The influence of accumulation time and pH of the electrolytic solution were investigated. The calibration graph obtained under the optimized conditions was linear with a correlation coefficient of 0.9813 at levels near the detection limits up to at least 5.32 x 10(-9) mol L-1 with the relative standard deviation (RSD) lower than 3.37%. Interferences by some metals were investigated. Fe, Zn, Cu, MnO4 and Hg apparently affected the peak currents P-1 and P-2 of diquat. The natural phosphate modified platinum electrode was applied to the determination of diquat in natural water samples. The results indicate that this electrode is sensitive and effective for the determination of diquat. (C) 2012 Production and hosting by Elsevier B.V.
引用
收藏
页码:S671 / S676
页数:6
相关论文
共 50 条
  • [21] Square Wave Voltammetric Determination of Lead(II) Ions Using a Carbon Paste Electrode Modified by a Thiol-Functionalized Kaolinite
    Tonle, Ignas K.
    Letaief, Sadok
    Ngameni, Emmanuel
    Walcarius, Alain
    Detellier, Christian
    ELECTROANALYSIS, 2011, 23 (01) : 245 - 252
  • [22] Square Wave Voltammetric Determination of Fomesafen Herbicide Using Modified Nanostructure Carbon Paste Electrode as a Sensor and Application to Food Samples
    Demir, Ersin
    Inam, Recai
    FOOD ANALYTICAL METHODS, 2017, 10 (01) : 74 - 82
  • [23] Square wave voltammetric determination of anticancer drug flutamide using carbon paste electrode modified by CuO/GO/PANI nanocomposite
    Afzali, Moslem
    Mostafavi, Ali
    Shamspur, Tayebeh
    ARABIAN JOURNAL OF CHEMISTRY, 2020, 13 (01) : 3255 - 3265
  • [24] Electrochemical studies and square wave voltammetry of paraquat at natural phosphate modified carbon paste electrode
    El Mhammedi, M. A.
    Bakasse, M.
    Chtaini, A.
    JOURNAL OF HAZARDOUS MATERIALS, 2007, 145 (1-2) : 1 - 7
  • [25] Electrooxidation of thiourea and its square-wave voltammetric determination using pencil graphite electrode
    Levent, Abdulkadir
    Keskin, Ertugrul
    Yardim, Yavuz
    Senturk, Zuhre
    REVIEWS IN ANALYTICAL CHEMISTRY, 2011, 30 (01) : 45 - 51
  • [26] Square wave voltammetric determination of paracetamol at chitosan modified carbon paste electrode: Application in natural water samples, commercial tablets and human urines
    El Bouabi, Y.
    Farahi, A.
    Labjar, N.
    El Hajjaji, S.
    Bakasse, M.
    El Mhammedi, M. A.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 58 : 70 - 77
  • [27] Square Wave Voltammetric Determination of Ibuprofen at Poly(L-Aspartic Acid) Modified Glassy Carbon Electrode
    Mekassa, Birhanu
    Tessema, Merid
    Chandravanshi, Bhagwan Singh
    Tefera, Molla
    IEEE SENSORS JOURNAL, 2018, 18 (01) : 37 - 44
  • [28] Square-Wave Adsorptive Stripping Voltammetric Determination of Serotonin at Glassy Carbon Electrode Modified with Safranine O
    Filik, Hayati
    Avan, Asiye Aslihan
    Aydar, Sevda
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (06): : 2922 - 2933
  • [29] Square-wave anodic stripping voltammetric determination of thallium(I) at a Nafion mercury film modified electrode
    Lu, TH
    Yang, HY
    Sun, IW
    TALANTA, 1999, 49 (01) : 59 - 68
  • [30] EDTA salt modified carbon paste electrode for square wave voltammetric determination of theophylline in pharmaceutical tablet formulation
    Moges, Amsalu
    Dawit, Mulugeta
    Turbale, Mahilet
    Amare, Meareg
    PLOS ONE, 2022, 17 (06):