Square wave voltammetric determination of diquat using natural phosphate modified platinum electrode

被引:9
|
作者
El Harmoudi, H. [1 ,2 ]
Achak, M. [1 ,2 ]
Lahrich, S. [1 ]
Farahi, A. [1 ,2 ]
El Gaini, L. [2 ]
Bakasse, M. [2 ]
El Mhammedi, M. A. [1 ]
机构
[1] Univ Chouaib Doukkali, Fac Sci, Equipe Anal Micropolluants Organ, El Jadida, Morocco
[2] Univ Hassan 1er, Fac Polydisciplinaire, Equipe Chim Analyt & Modelisat Stat, BP 145, Khouribga, Morocco
关键词
Platinum electrode; Natural phosphate; Diquat; Square wave voltammetry; CARBON-PASTE ELECTRODE; CHEMICALLY-MODIFIED ELECTRODES; LIQUID-CHROMATOGRAPHY; OLIVE OIL; PARAQUAT; EXTRACTION; SAMPLES; WATER; ACID;
D O I
10.1016/j.arabjc.2012.11.007
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A platinum electrode modified with natural phosphate (NP) was evaluated as an electro-chemical sensor for diquat (DQ) in aqueous medium. The electrode was prepared by the deposition of natural phosphate on the platinum surface. Diquat was preconcentrated on the surface of the modified electrode by adsorbing with natural phosphate and reduced at a negative potential in 0.1 M K2SO4 solution. The influence of accumulation time and pH of the electrolytic solution were investigated. The calibration graph obtained under the optimized conditions was linear with a correlation coefficient of 0.9813 at levels near the detection limits up to at least 5.32 x 10(-9) mol L-1 with the relative standard deviation (RSD) lower than 3.37%. Interferences by some metals were investigated. Fe, Zn, Cu, MnO4 and Hg apparently affected the peak currents P-1 and P-2 of diquat. The natural phosphate modified platinum electrode was applied to the determination of diquat in natural water samples. The results indicate that this electrode is sensitive and effective for the determination of diquat. (C) 2012 Production and hosting by Elsevier B.V.
引用
收藏
页码:S671 / S676
页数:6
相关论文
共 50 条
  • [1] Evaluation of a platinum electrode modified with hydroxyapatite in the lead(II) determination in a square wave voltammetric procedure
    El Mhammedi, M. A.
    Achak, M.
    Bakasse, M.
    ARABIAN JOURNAL OF CHEMISTRY, 2013, 6 (03) : 299 - 305
  • [2] Square wave voltammetric determination of paraquat and diquat in aqueous solution
    Walcarius, A
    Lamberts, L
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 406 (1-2) : 59 - 68
  • [3] Square wave voltammetric determination of paraquat and diquat in aqueous solution
    Walcarius, A.
    Lamberts, L.
    Journal of Electroanalytical Chemistry, 1996, 406 (1-2): : 59 - 68
  • [4] Square-Wave Voltammetric Determination of Nanomolar Levels of Linuron in Environmental Water Samples Using a Glassy Carbon Electrode Modified with Platinum Nanoparticles within a Dihexadecyl Phosphate Film
    Marreto, Paola D.
    Trench, Aline B.
    Vicentini, Fernando C.
    Figueiredo-Filho, Luiz C. S.
    Medeiros, Roberta A.
    Pereira, Ernesto. C.
    Fatibello-Filho, Orlando
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2015, 68 (05) : 800 - 805
  • [5] Square wave voltammetric determination of pyridoxine in pharmaceutical preparations using cobalthexacyanoferrate modified carbon paste electrode
    Mekonnen, Alemu
    Saini, R.C.
    Tadese, Abraha
    Pal, Rishi
    Journal of Chemical and Pharmaceutical Research, 2014, 6 (01) : 544 - 551
  • [6] Square Wave Voltammetric Determination of Dexamethasone on a Multiwalled Carbon Nanotube Modified Pencil Electrode
    Rezaei, B.
    Zare, S. Z. Mirahmadi
    Ensafi, Ali A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (05) : 897 - 904
  • [7] Square-wave voltammetric determination of paraquat at carbon paste electrode modified with hydroxyapatite
    El Mhanunedi, Moulay Abderrahim
    Bakasse, Mina
    Chtaini, Abdelilah
    ELECTROANALYSIS, 2007, 19 (16) : 1727 - 1733
  • [8] Voltammetric Determination of α-Lipoic Acid using Poly(Vanillin) Modified Platinum Electrode
    Duran, Serap Titretir
    Hassine, Chedia Ben Ali
    Burc, Muammer
    Gungor, Oznur
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (06): : 857 - 869
  • [9] Square wave voltammetry for analytical determination of paracetamol using cobalt microparticles film modified platinum electrode
    Merzak Doulache
    Boubakeur Saidat
    Mohamed Trari
    Russian Journal of Electrochemistry, 2017, 53 : 461 - 468
  • [10] Square Wave Voltammetry for Analytical Determination of Paracetamol Using Cobalt Microparticles Film Modified Platinum Electrode
    Doulache, Merzak
    Saidat, Boubakeur
    Trari, Mohamed
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2017, 53 (05) : 461 - 468