Critical heat flux in pool boiling on a vertical heater

被引:1
|
作者
Monde, M [1 ]
Inoue, T [1 ]
Mitsutake, Y [1 ]
机构
[1] KURUME INST TECHNOL, DEPT ENGN MECH, KURUME, FUKUOKA 2228, JAPAN
关键词
D O I
10.1007/s002310050142
中图分类号
O414.1 [热力学];
学科分类号
摘要
Critical heat flux during pool boiling on a vertical heater of wire or plate has been measured employing water and R113. The experiment was made for a wire of 0.5 to 2 mm in diameter and for a plate of 5, 7 and 30 mm in width and from 20 to 300 mm in height. The pressure was 1 and 2 bar for water and 1, 2, 3 and 4 bar for R113. The experiment shows that for the case of both wire and plate of 5, 7 mm, a large coalesced bubble entirely surrounds the vertical heater and rises surrounding it, while for the case of w = 30 mm, a large bubble cannot surround and rises along its surface. The characteristic of CHF can be divided into two regimes depending on the flow condition when CHF takes place. Correlations are proposed for the CHF of the wire and the plate of w = 5, and 7 mm, yielding good accuracy. The CHF for the plate of w = 30 mm has a similar tendency to that in one side headed surface and can be predicted reasonably by existing correlation for one side heated surface.
引用
收藏
页码:435 / 440
页数:6
相关论文
共 50 条