Experimental Validation and Performance Analysis of the Clear-PEM Data Acquisition Electronics

被引:0
|
作者
Bugalho, Ricardo [1 ]
Bexiga, Vasco [2 ]
Carrico, Bruno [1 ]
Ferreira, Claudia S. [1 ]
Ferreira, Miguel [1 ]
Ferreira, Nuno C. [3 ]
Leong, Carlos [2 ]
Lousa, Pedro [4 ]
Machado, Pedro [2 ]
Moura, Rui [1 ]
Neves, Pedro [4 ]
Ortigao, Catarina [1 ]
Piedade, Femando [4 ]
Rego, Joel [4 ]
Rodrigues, Pedro [1 ]
Teixeira, Isabel C. [2 ]
Teixeira, Joao P. [2 ]
Silva, Jose C. [1 ]
Trindade, Andreia [1 ]
Varela, Joao [1 ]
机构
[1] LIP, Lab Instrumentacao & Fis Expt Particulas, P-1000 Lisbon, Portugal
[2] INESC ID, Lisbon, Portugal
[3] Univ Coimbra, Inst Biofisica Biomath, Fac Med, Coimbra, Portugal
[4] Inst Novas Tecnol, Lisbon, Portugal
来源
2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9 | 2009年
关键词
positron emission; tomography; mammography; data acquisition;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Obtaining images with high resolution and contrast from short exams is crucial for the viability of Positron Emission Mammography as an early breast cancer detection technique. The Clear-PEM detector is a Positron Emission Mammography scanner, developed by the Portuguese Consortium in the framework of the Crystal Clear Collaboration at CERN, based on high-granularity avalanche photodiodes readout with 12288 channels, coupled to pixilated 2x2x20 mm(3) LYSO:Ce crystals in a double readout configuration. The scanner features a high bandwidth three-level acquisition system with negligible dead time in order to minimize exam time. The frontend is instrumented with low-noise amplifier/discriminator/multiplexer ASICs (L0 trigger) and free-running ADCs while the off-ddetector electronics, implemented in FPGAs, computes the trigger primitives from the pulse amplitude and timing. With this information the readout electronics selects interesting photoelectric events and groups multi-hit events due to in-Compton scatter into possible coincidences. After a first-level trigger (L1) is generated, filtered data is read out over a high speed data link into a second-level (L2) software trigger which reprocesses the selected events in temporal coincidence with more accurate energy and time extraction algorithms. The DOI coordinate and the re-validated energy and time allow to achieve an improved reconstruction of in-detector Compton scattering and rejection of random and scattered coincidences. On this paper, we report on the experimental validation, characterization and optimization of the L1 data acquisition electronics, readout link and L2 software trigger and present performance results. We discuss the validation of the associated operation software.
引用
收藏
页码:3340 / +
页数:2
相关论文
共 50 条
  • [41] Analysis of PEM fuel cell experimental data using principal component analysis and multi linear regression
    Placca, Latevi
    Kouta, Raed
    Candusso, Denis
    Blachot, Jean-Francois
    Charon, Willy
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (10) : 4582 - 4591
  • [42] A Comprehensive CFD Assessment of Wheat Flow in Wheat Conveying Cyclone Validation and Performance Analysis by Experimental Data
    Dizajyekan, Sajed Naiemi
    Shahgholi, Gholamhossein
    Rezvanivand Fanaei, Adel
    Rostampour, Vahid
    Sharabiani, Vali Rasooli
    Szymanek, Mariusz
    Marczuk, Andrzej
    PROCESSES, 2022, 10 (01)
  • [43] Validation of a Novel Wearable Multistream Data Acquisition and Analysis System for Ergonomic Studies
    Ascari, Luca
    Marchenkova, Anna
    Bellotti, Andrea
    Lai, Stefano
    Moro, Lucia
    Koshmak, Konstantin
    Mantoan, Alice
    Barsotti, Michele
    Brondi, Raffaello
    Avveduto, Giovanni
    Sechi, Davide
    Compagno, Alberto
    Avanzini, Pietro
    Ambeck-Madsen, Jonas
    Vecchiato, Giovanni
    SENSORS, 2021, 21 (24)
  • [44] VALIDATION OF A DIGITAL DATA-ACQUISITION AND ANALYSIS SYSTEM IN A CARDIOVASCULAR TOXICOLOGY LABORATORY
    SARAZAN, RD
    TOXICOLOGY METHODS, 1994, 4 (04): : 274 - 291
  • [45] Experimental Evaluation Performance of Ultrasonic Multisensor Deployment Geometries for a Data Acquisition System
    Essiben, Jean-Francois Dikoundou
    Ihonock, Luc Eyembe
    Matanga, Jacques
    Suk Joe, Yong
    INTERNATIONAL JOURNAL OF DISTRIBUTED SENSOR NETWORKS, 2024, 2024
  • [46] Spatial characteristics of the MIMO wireless channel: Experimental data acquisition and analysis
    Wallace, JW
    Jensen, MA
    2001 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOLS I-VI, PROCEEDINGS: VOL I: SPEECH PROCESSING 1; VOL II: SPEECH PROCESSING 2 IND TECHNOL TRACK DESIGN & IMPLEMENTATION OF SIGNAL PROCESSING SYSTEMS NEURALNETWORKS FOR SIGNAL PROCESSING; VOL III: IMAGE & MULTIDIMENSIONAL SIGNAL PROCESSING MULTIMEDIA SIGNAL PROCESSING, 2001, : 2497 - 2500
  • [47] High performance shotgun proteomics data validation using experimental parameters
    Heller, M.
    Ye, M.
    Michel, P.
    Morier, P.
    Stadler, D.
    Aebersold, R.
    Reymond, F.
    Rossier, J.
    MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (08) : S22 - S22
  • [48] Multicriteria Sensitivity Analysis for Numerical Model Validation of Experimental Data
    Indriyantho, Bobby Rio
    Purnomo, Joko
    Purwanto
    Ottele, Marc
    Han, Ay Lie
    Gan, Buntara Sthenly
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2024, 15 (06) : 1644 - 1662
  • [49] Experimental validation of two-phase pressure drop multiplier as a diagnostic tool for characterizing PEM fuel cell performance
    Banerjee, Rupak
    Howe, Danielle
    Mejia, Valentina
    Kandlikar, Satish G.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (31) : 17791 - 17801
  • [50] PERFORMANCE ANALYSIS AND EXPERIMENTAL VALIDATION OF THE DIRECT STRAIN IMAGING METHOD
    Iliopoulos, Athanasios
    Michopoulos, John G.
    Hermanson, John C.
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2013, VOL 2A, 2014,