Experimental Validation and Performance Analysis of the Clear-PEM Data Acquisition Electronics

被引:0
|
作者
Bugalho, Ricardo [1 ]
Bexiga, Vasco [2 ]
Carrico, Bruno [1 ]
Ferreira, Claudia S. [1 ]
Ferreira, Miguel [1 ]
Ferreira, Nuno C. [3 ]
Leong, Carlos [2 ]
Lousa, Pedro [4 ]
Machado, Pedro [2 ]
Moura, Rui [1 ]
Neves, Pedro [4 ]
Ortigao, Catarina [1 ]
Piedade, Femando [4 ]
Rego, Joel [4 ]
Rodrigues, Pedro [1 ]
Teixeira, Isabel C. [2 ]
Teixeira, Joao P. [2 ]
Silva, Jose C. [1 ]
Trindade, Andreia [1 ]
Varela, Joao [1 ]
机构
[1] LIP, Lab Instrumentacao & Fis Expt Particulas, P-1000 Lisbon, Portugal
[2] INESC ID, Lisbon, Portugal
[3] Univ Coimbra, Inst Biofisica Biomath, Fac Med, Coimbra, Portugal
[4] Inst Novas Tecnol, Lisbon, Portugal
来源
2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9 | 2009年
关键词
positron emission; tomography; mammography; data acquisition;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Obtaining images with high resolution and contrast from short exams is crucial for the viability of Positron Emission Mammography as an early breast cancer detection technique. The Clear-PEM detector is a Positron Emission Mammography scanner, developed by the Portuguese Consortium in the framework of the Crystal Clear Collaboration at CERN, based on high-granularity avalanche photodiodes readout with 12288 channels, coupled to pixilated 2x2x20 mm(3) LYSO:Ce crystals in a double readout configuration. The scanner features a high bandwidth three-level acquisition system with negligible dead time in order to minimize exam time. The frontend is instrumented with low-noise amplifier/discriminator/multiplexer ASICs (L0 trigger) and free-running ADCs while the off-ddetector electronics, implemented in FPGAs, computes the trigger primitives from the pulse amplitude and timing. With this information the readout electronics selects interesting photoelectric events and groups multi-hit events due to in-Compton scatter into possible coincidences. After a first-level trigger (L1) is generated, filtered data is read out over a high speed data link into a second-level (L2) software trigger which reprocesses the selected events in temporal coincidence with more accurate energy and time extraction algorithms. The DOI coordinate and the re-validated energy and time allow to achieve an improved reconstruction of in-detector Compton scattering and rejection of random and scattered coincidences. On this paper, we report on the experimental validation, characterization and optimization of the L1 data acquisition electronics, readout link and L2 software trigger and present performance results. We discuss the validation of the associated operation software.
引用
收藏
页码:3340 / +
页数:2
相关论文
共 50 条
  • [1] The Clear-PEM electronics system
    Albuquerque, Edgar
    Bento, Pedro
    Leong, Carlos
    Goncalves, Fernando
    Nobre, Joao
    Rego, Joel
    Relvas, Paulo
    Lousa, Pedro
    Rodrigues, Pedro
    Teixeira, Isabel C.
    Teixeira, Joao P.
    Silva, Luis
    Silva, M. Medeiros
    Trindade, Andreia
    Varela, Joao
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2704 - 2711
  • [2] Experimental characterization of the Clear-PEM scanner spectrometric performance
    Bugalho, R.
    Carrico, B.
    Ferreira, C. S.
    Frade, M.
    Ferreira, M.
    Moura, R.
    Ortigao, C.
    Pinheiro, J. F.
    Rodrigues, P.
    Rolo, I.
    Silva, J. C.
    Trindade, A.
    Varela, J.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [3] Reconstruction of Clear-PEM data with STIR
    Martins, Monica V.
    Matela, Nuno
    Rodrigues, Pedro
    Trindade, Andreia
    Oliveira, Nuno
    Correia, Marta
    Cordeiro, Hugo
    Ferreira, Nuno C.
    Varela, Joao
    Almeida, Pedro
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2098 - 2102
  • [4] Architecture and first prototype tests of the clear-PEM electronics systems
    Bento, P
    Leong, C
    Gonçalves, F
    Teixeira, IC
    Teixeira, JP
    Nobre, J
    Relvas, P
    Silva, L
    Rodrigues, P
    Trindade, A
    Varela, J
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3796 - 3800
  • [5] First experimental results with the clear-PEM detector
    Abreu, Maria C.
    Aguiar, Joao D.
    Albuquerque, Edgar
    Almeida, Fernando G.
    Almeida, Pedro
    Amaral, Pedro
    Bento, Pedro
    Bugalho, Ricardo
    Carrico, Bruno
    Cordeiro, Hugo
    Ferreira, Miguel
    Ferreira, Nuno C.
    Goncalves, Fernado
    Leon-, Carlos
    Lopes, Filipe
    Lousa, Pedro
    Martins, Monica V.
    Matela, Nuno
    Mendes, Pedro R.
    Moura, Rui
    Nobre, Joao
    Oliveira, Nuno
    Ortigao, Catarina
    Peralta, Luis
    Rego, Joel
    Ribeiro, Rui
    Rodrigues, Pedro
    Santos, Ana I.
    Silva, Jose C.
    Silva, Manuel M.
    Teixeira, Isabel C.
    Teixeira, Joao P.
    Trindade, Andreia
    Varela, Joao
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1662 - 1666
  • [6] Clear-PEM Data Reconstruction Using STIR
    Martins, M. V.
    Matela, N.
    Oliveira, N.
    Trindade, A.
    Rodrigues, P.
    Ferreira, N.
    Varela, J.
    Almeida, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S34 - S34
  • [7] Characterization of the Clear-PEM Breast Imaging Scanner Performance
    Albuquerque, E.
    Almeida, F. G.
    Almeida, P.
    Auffray, E.
    Barbosa, J.
    Bastos, A. L.
    Bexiga, V.
    Bugalho, R.
    Cardoso, C.
    Carmona, S.
    Carneiro, J. F.
    Carrico, B.
    Ferreira, C. S.
    Ferreira, N. C.
    Ferreira, M.
    Frade, M.
    Goncalves, F.
    Guerreiro, C.
    Lecoq, P.
    Leong, C.
    Lousa, P.
    Machado, P.
    Martins, M. V.
    Matela, N.
    Moura, R.
    Neves, J.
    Neves, P.
    Oliveira, N.
    Ortigao, C.
    Piedade, F.
    Pinheiro, J. F.
    Relvas, P.
    Rivetti, A.
    Rodrigues, P.
    Rolo, I.
    Santos, A. I.
    Santos, J.
    Silva, M. M.
    Tavernier, S.
    Teixeira, I. C.
    Teixeira, J. P.
    Silva, J. C.
    Silva, R.
    Trindade, A.
    Varela, J.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3487 - +
  • [8] Performance and quality control of Clear-PEM detector modules
    Amaral, Pedro
    Carrico, Bruno
    Ferreira, Miguel
    Moura, Rui
    Ortigao, Catarina
    Rodrigues, Pedro
    Da Silva, Jose C.
    Trindade, Andreia
    Varela, Joao
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 1123 - 1126
  • [9] Initial Evaluation of Real Data Obtained With the Clear-PEM Scanner
    Ferreira, C. S.
    Matela, N.
    Bugalho, R.
    Ortigao, C.
    Teixeira, A.
    Oliveira, N.
    Varela, J.
    Almeida, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S309 - S309
  • [10] Performance simulation studies of the clear-PEM DAQ/trigger system
    Bento, Pedro
    Goncalves, Fernando
    Leong, Carlos
    Lousa, Pedro
    Nobre, Joao
    Rego, Joel
    Relvas, Paulo
    Rodrigues, Pedro
    Silva, Jose C.
    Silva, Luis
    Teixeira, Isabel C.
    Teixeira, Joao P.
    Trindade, Andreia
    Varela, Joao
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (04) : 2102 - 2111