Image distortions in SEM and their influences on EBSD measurements

被引:105
|
作者
Nolze, Gert [1 ]
机构
[1] Fed Inst Mat Res & Testing, D-12205 Berlin, Germany
关键词
EBSD; tilted sample; image distortion;
D O I
10.1016/j.ultramic.2006.07.003
中图分类号
TH742 [显微镜];
学科分类号
摘要
The high sample tilt angle commonly necessary for an orientation determination by EBSD (electron back-scatter diffraction) is responsible for some simple geometrically caused, but nevertheless essential, image distortions. First of all, the influence of the tilt correction and also the trapezium distortion which appears at low magnifications will be discussed. In the second part, an additional rhomboidal distortion will be introduced which is independent of the magnification used. This distortion appears if the scanned sample surface is out of plane to the tilted stage. Even a small deviation from the parallelity produces an approximately three times bigger error of the Euler angle 91 when the sample alignment is based on the image captured from the highly tilted sample. This effect especially concerns small samples (e.g. FIB-lamellae) since they cannot be exactly aligned, but the measurements of bigger samples can also be influenced. As an example a correction procedure is described in detail, based on a repetition of the measurement after a 180 degrees sample rotation. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:172 / 183
页数:12
相关论文
共 50 条
  • [21] Surface Decoration for Improving the Accuracy of Displacement Measurements by Digital Image Correlation in SEM
    B. Winiarski
    G. S. Schajer
    P. J. Withers
    Experimental Mechanics, 2012, 52 : 793 - 804
  • [22] Surface Decoration for Improving the Accuracy of Displacement Measurements by Digital Image Correlation in SEM
    Winiarski, B.
    Schajer, G. S.
    Withers, P. J.
    EXPERIMENTAL MECHANICS, 2012, 52 (07) : 793 - 804
  • [23] DISPERSOID SIZE DISTRIBUTION MEASUREMENTS IN A SEM EQUIPPED WITH AN IMAGE-ANALYSIS SYSTEM
    SODAHL, O
    HJELEN, J
    DONS, AL
    JOHNSEN, PO
    ULTRAMICROSCOPY, 1986, 19 (04) : 408 - 409
  • [24] SEM-EBSD analysis on symplectic inclusion in the QUE 93148 olivine
    Mikouchi, T
    Righter, K
    METEORITICS & PLANETARY SCIENCE, 2005, 40 (09) : A103 - A103
  • [25] Novel Fractgraphy of Ni-Based Alloy by SEM/EBSD Method
    Kubushiro, Keiji
    Ota, Yutaro
    Sakakibara, Yohei
    Okada, Hitoshi
    PROCEEDINGS OF THE 9TH INTERNATIONAL SYMPOSIUM ON SUPERALLOY 718 & DERIVATIVES: ENERGY, AEROSPACE, AND INDUSTRIAL APPLICATIONS, 2018, : 669 - 678
  • [26] Cryogenic EBSD on ice: preserving a stable surface in a low pressure SEM
    Weikusat, I.
    De Winter, D. A. M.
    Pennock, G. M.
    Hayles, M.
    Schneijdenberg, C. T. W. M.
    Drury, M. R.
    JOURNAL OF MICROSCOPY, 2011, 242 (03) : 295 - 310
  • [27] Plagioclase preferred orientation by TOF neutron diffraction and SEM-EBSD
    Xie, YX
    Wenk, HR
    Matthies, S
    TECTONOPHYSICS, 2003, 370 (1-4) : 269 - 286
  • [28] SEM, EBSD, laser confocal microscopy and FE-SEM data from modern Glycymeris shell layers
    Crippa, Gaia
    Griesshaber, Erika
    Checa, Antonio G.
    Harper, Elizabeth M.
    Roda, Maria Simonet
    Schmahl, Wolfgang W.
    DATA IN BRIEF, 2020, 33
  • [29] Measurements of perceived curvature distortions
    Bertulis, A
    Bulatov, A
    Gutauskas, A
    PERCEPTION, 2004, 33 : 85 - 85
  • [30] About the reliability of EBSD measurements: Data enhancement
    Nolze, G.
    Winkelmann, A.
    EMAS 2019 WORKSHOP - 16TH EUROPEAN WORKSHOP ON MODERN DEVELOPMENTS AND APPLICATIONS IN MICROBEAM ANALYSIS, 2020, 891