Short-circuit Current Characteristics of Distributed Power and Fault Location Method after Distributed Power is Connected

被引:0
|
作者
Zhao Dan [1 ]
Zhang Xinyu [1 ]
Wang Yang [2 ]
Tian Ye [1 ]
Wang Yanan [1 ]
Lang Yexing [1 ]
机构
[1] State Grid Liaoning Elect Power Co Ltd, Elect Power Res Inst, 39 Siping St, Shenyang, Peoples R China
[2] State Grid Liaoning Elect Power Co Ltd, 18 Ningbo St, Shenyang, Peoples R China
关键词
fault location; distribution network; abrupt current; matrix algorithm; overcurrent;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the increasing penetration of distributed power sources, the fault location of distribution networks after short-circuit faults becomes more complicated. Therefore, it is of great significance to study the fault location methods after the access of distributed power sources. This paper proposes a new fault location algorithm for distribution networks based on the abrupt current direction. The fault location is determined based on the abrupt direction of the short circuit current and the magnitude of the short circuit current. The matrix algorithm is used to locate the fault, and direction of the short circuit current of detection terminal in the network is taken as the research object. Based on the directivity of the distribution network, the continuity and directivity of the fault overcurrent are combined to determine the fault location.
引用
收藏
页码:1782 / 1786
页数:5
相关论文
共 50 条
  • [1] AC distributed power supplies used for solid state short-circuit fault current limiter
    Wen Huiqing
    Wen Xuhui
    Lu Zhengyu
    2007 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-4, 2007, : 879 - 883
  • [2] A New Fault Location Scheme Based on Distributed Short-circuit, Current in Distribution System with DGs
    Ma, Jinjie
    Lu, Yuping
    Du, Jiao
    Lin, Xia
    2008 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), VOLS 1 AND 2, 2008, : 1189 - 1194
  • [3] Short-circuit Current Limiting for Ring Distributed Power System Integrated with Multiple Sources
    XinLiu
    Chen, Hongkun
    Tao, Yubo
    Chencong
    Huqian
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [4] Fault detection and analysis of distributed power system short-circuit using wavelet fractal network
    Song Yuhai
    Wang Guangjian
    Chen Xiangguo
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL III, 2007, : 422 - +
  • [5] A Section Location Method of Single-Phase Short-Circuit Faults for Distribution Networks Containing Distributed Generators Based on Fusion Fault Confidence of Short-Circuit Current Vectors
    Xu, Shoudong
    Ouyang, Jinxin
    Chen, Jiyu
    Xiong, Xiaofu
    ELECTRONICS, 2024, 13 (09)
  • [6] Amelioration of Short-Circuit Effects on Power Transformers with Fault Current Limiters
    Khodabakhsh, Javad
    Pourmand, Elnaz
    2014 INTERNATIONAL CONFERENCE ON ADVANCES IN ELECTRICAL ENGINEERING (ICAEE), 2014,
  • [7] Part 1: A study on the short-circuit analysis method of a power system enhanced by distributed generation
    Kim I.
    Transactions of the Korean Institute of Electrical Engineers, 2022, 71 (03): : 469 - 476
  • [8] A Study on the Effect of Distributed Generation on Short-Circuit Current
    Kim, Insu
    Harley, Ronald G.
    2016 CLEMSON UNIVERSITY POWER SYSTEMS CONFERENCE (PSC), 2016,
  • [9] Influence of Voltage Support by Converter Based Distributed Generation on the Short-Circuit Power
    Wijnhoven, T.
    Tant, J.
    Deconinck, G.
    Neumann, T.
    Erlich, I.
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [10] A practical method to calculate short-circuit current in power system connected with doubly fed induction generators
    Xing, Luhua
    Chen, Qing
    Wu, Changjing
    Huang, Debin
    Tang, Yi
    Dianwang Jishu/Power System Technology, 2013, 37 (04): : 1121 - 1127