A practical method to calculate short-circuit current in power system connected with doubly fed induction generators

被引:0
|
作者
Xing, Luhua [1 ]
Chen, Qing [1 ]
Wu, Changjing [1 ]
Huang, Debin [2 ]
Tang, Yi [2 ]
机构
[1] Key Laboratory of Power System Intelligent Dispatch and Control Ministry of Education, Shandong University, Jinan 250061, Shandong Province, China
[2] Dispatching Center of Shandong Electric Power Corporation, Jinan 250001, Shandong Province, China
来源
关键词
Stators - Asynchronous generators - Power quality - Timing circuits - Electric network analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Electromagnetic transient model of doubly fed induction generator (DFIG) during symmetrical short-circuit fault occurred in power system connected with DFIG and fault transient process of magnetic linkage in the stator and the rotor of DFIG are analyzed, and then the expression of short-circuit current in stator of DFIG under different stator voltage drop extents is derived and a method to correct the stator voltage drop coefficient, by which the calculation error of short-circuit current can be effectively reduced, is put forward. A practical method to calculate short-circuit current caused by symmetrical short-circuit fault occurred in power system connected with DFIGs is proposed. Taking the fault point as boundary point, the power system containing DFIG is simplified to an equivalent two-branch network composed of generator branch and system branch, then the operational curves of periodic components of short-circuit currents in generator branch and system branch are solved respectively to determine the amplitude of periodic components of short-circuit currents at the fault point, and expressions of aperiodic component and rotor frequency component of short circuit current at the fault point are derived.
引用
收藏
页码:1121 / 1127
相关论文
共 50 条
  • [1] Short-circuit calculation method for unbalanced distribution networks with doubly fed induction generators
    Xiao, Fan
    Xia, Yongjun
    Zhang, Kanjun
    Zhang, Zhe
    Yin, Xianggen
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 210
  • [2] Concise short-circuit current expression for grid-connected doubly fed induction generator
    Ji, Tianyao
    Mo, Chun
    Zhang, Luliang
    Lu, Aoxuan
    Dai, Manru
    ELECTRICAL ENGINEERING, 2025,
  • [3] Symmetrical and unsymmetrical short-circuit current of squirrel-cage and doubly-fed induction generators
    Sulla, F.
    Svensson, J.
    Samuelsson, O.
    ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (07) : 1610 - 1618
  • [4] Research on short-circuit current of doubly-fed induction generators under rotor excitation control
    Ouyang, Jinxin
    Xiong, Xiaofu
    Ouyang, Jinxin, 1600, Chinese Society for Electrical Engineering (34): : 6083 - 6092
  • [5] Short-circuit current of wind turbines with doubly fed induction generator
    Morren, Johan
    de Haan, Sjoerd W. H.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 174 - 180
  • [6] Practical calculation model of three-phase short-circuit current for doubly-fed induction generator
    Shi, Yihui
    Lu, Zongxiang
    Min, Yong
    Qiao, Ying
    Chen, Huifen
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2011, 35 (08): : 38 - 43
  • [7] Characteristics of Short-Circuit Current in Distribution Network with Doubly-Fed Wind Power System
    Xi X.
    Xing C.
    Qin R.
    He T.
    He P.
    Meng X.
    Cheng C.
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2023, 57 (07): : 921 - 927
  • [8] Short-circuit Current Calculation Method of Doubly Fed Induction Generator Considering Control Strategy Switching
    Liu T.
    Zhang Y.
    Wang M.
    Zhang Y.
    Qin X.
    Wang Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (10): : 3330 - 3338
  • [9] Short-Circuit Current of a Doubly-Fed Induction Generator: Analytical Solution and Insights
    Marmolejo, Alejandro
    Palazzo, Mirko
    Delfanti, Maurizio
    2014 IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2014, : 128 - 133
  • [10] Analysis of three-phase short-circuit current characteristics of doubly fed induction generator
    Fan X.
    Sun S.
    Sun D.
    Hai S.
    Wang Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (18): : 38 - 48