Comparison of Three-Dimensional Planning-Assisted and Conventional Acetabular Cup Positioning in Total Hip Arthroplasty A Randomized Controlled Trial

被引:43
|
作者
Sariali, Elhadi [1 ,2 ]
Boukhelifa, Nadia [1 ,3 ]
Catonne, Yves [1 ,2 ]
Moussellard, Hugues Pascal [1 ,2 ]
机构
[1] Hop La Pitie Salpetriere, Paris, France
[2] Hop Univ La Pitie Salpetriere Charles Foix, AP HP, Paris, France
[3] INRIA, Saclay, France
来源
关键词
COMPONENT ORIENTATION; REPLACEMENT; RECONSTRUCTION; NAVIGATION; OSTEOARTHRITIS; DISLOCATION; PLACEMENT; ACCURACY; LIGAMENT; ANATOMY;
D O I
10.2106/JBJS.N.00753
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Malpositioning of the acetabular cup during total hip arthroplasty increases the risk of dislocation, edge-loading, squeaking, early wear, and loosening. We hypothesized that the use of three-dimensional (3-D) visualization tools to identify the planned cup position relative to the acetabular edge intraoperatively would increase the accuracy of cup orientation. The purpose of this study was to compare 3-D planning-assisted implantation and freehand insertion of the acetabular cup. Methods: This was a prospective randomized controlled study of two groups of twenty-eight patients each. In the first group, cup positioning was guided by 3-D views of the cup within the acetabulum obtained during 3-D preoperative planning. In the control group, the cup was placed freehand. All of the patients were operated on by the same surgeon, through a minimally invasive direct anterior approach with the patient in the supine position. Cup anteversion and abduction angles were measured on 3-D computed tomography (CT) reconstructions. The main evaluation criterion was the percentage of outliers according to the Lewinnek safe zone. Results: Operative time did not differ between the two groups. The cup anteversion was more accurate in the 3-D planning group (mean difference from the planned angle [and standard deviation], -2.7 degrees +/- 5.4 degrees) compared with the freehand-placement group (6.6 degrees +/- 9.5 degrees). According to the Lewinnek safe zone, overall, the percentage of outliers was lower in the 3-D planning group (21%; six patients) than in the control group (46%; thirteen patients). According to the Callanan safe zone, the percentage of outliers was also lower in the 3-D planning group (25% versus 64%). Although cup abduction was also restored with greater accuracy in the 3-D planning group, on the basis of the Lewinnek safe zone, the percentage of abduction outliers was comparable between groups, with fewer high-abduction values, but more low-abduction values, in the 3-D planning group. Conclusions: Preoperative 3-D planning increased the accuracy of anteversion restoration and reduced the percentage of outliers without increasing the operative time. In this study, the same advantage could not be demonstrated for abduction.
引用
收藏
页码:108 / 116
页数:9
相关论文
共 50 条
  • [21] Three-Dimensional Models in Planning of Revision Hip Arthroplasty with Complex Acetabular Defects
    Gennadiy M. Kavalerskiy
    Valeriy Y. Murylev
    Yaroslav A. Rukin
    Pavel M. Elizarov
    Alexey V. Lychagin
    Evgeniya Y. Tselisheva
    Indian Journal of Orthopaedics, 2018, 52 : 625 - 630
  • [22] Accuracy of acetabular cup positioning in robotic-assisted total hip arthroplasty: a CT-based evaluation
    Singh, Ashish
    Kumar, Purushotam
    Kalyan, Kanukuntla
    Gundalli, Akash Chandrashekar
    Mane, Sudhir Shankar
    Swarnkar, Himanshu
    Singh, Lavanya
    SICOT-J, 2024, 10
  • [23] Three-Dimensional Templating for Acetabular Component Alignment During Total Hip Arthroplasty
    Elbuluk, Ameer M.
    Wojack, Paul
    Eftekhary, Nima
    Vigdorchik, Jonanathan M.
    ORTHOPEDICS, 2017, 40 (04) : E708 - E713
  • [24] Smartphone-assisted technique in total hip arthroplasty can improve the precision of acetabular cup placement: a randomised controlled trial
    Pongkunakorn, Anuwat
    Diewwattanawiwat, Kittipong
    Chatmaitri, Swist
    HIP INTERNATIONAL, 2021, 31 (01) : 50 - 57
  • [25] Two-Dimensional and Three-Dimensional Cup Coverage in Total Hip Arthroplasty with Developmental Dysplasia of the Hip
    Wang, Liao
    Thoreson, Andrew R.
    Trousdale, Robert T.
    Morrey, Bernard F.
    Dai, Kerong
    An, Kai-Nan
    JOURNAL OF BIOMECHANICS, 2013, 46 (10) : 1746 - 1751
  • [26] Does Robotic-Assisted Computer Navigation Affect Acetabular Cup Positioning in Total Hip Arthroplasty in the Obese Patient? A Comparison Study
    Gupta, Asheesh
    Redmond, John M.
    Hammarstedt, Jon E.
    Petrakos, Alexandra E.
    Vemula, S. Pavan
    Domb, Benjamin G.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (12): : 2204 - 2207
  • [27] Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating
    Sariali, E.
    Mauprivez, R.
    Khiami, F.
    Pascal-Mousselard, H.
    Catonne, Y.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (02) : 151 - 158
  • [28] Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty
    Wang, Ruoyu
    Zheng, Xiaojing
    Xu, Tianze
    Gong, Song
    Liu, Shaokai
    Han, Lizhi
    Yang, Shuhua
    Xu, Weihua
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2020, 8
  • [29] Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty
    Wang, Ruoyu
    Zheng, Xiaojing
    Xu, Tianze
    Gong, Song
    Liu, Shaokai
    Han, Lizhi
    Yang, Shuhua
    Xu, Weihua
    Frontiers in Bioengineering and Biotechnology, 2020, 8
  • [30] Shape suitability and mechanical safety of customised hip implants: Three-dimensional printed acetabular cup for hip arthroplasty
    Kang, Yeokyung
    Sun, Doo-Hoon
    Park, Jong-Chul
    Kim, Jungsung
    JOURNAL OF ORTHOPAEDICS, 2022, 34 : 166 - 172