Determination of perfluorooctanoic acid and perfluorooctane sulfonate by automated in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry

被引:63
|
作者
Saito, Keita [1 ]
Uemura, Emiko [1 ]
Ishizaki, Atsushi [1 ]
Kataoka, Hiroyuki [1 ]
机构
[1] Shujitsu Univ, Sch Pharm, Okayama 7038516, Japan
关键词
In-tube solid-phase microextraction; Automated sample preparation; Liquid chromatography-mass spectrometry; Perfluorooctanoic acid; Perfluorooctane sulfonate; PERFLUORINATED COMPOUNDS; WASTE-WATER; ENVIRONMENTAL WATERS; SAMPLE PREPARATION; TRACE LEVELS; TAP WATER; SURFACTANTS; JAPAN; RIVER; PFOA;
D O I
10.1016/j.aca.2009.11.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed a simple, rapid, and sensitive method for the determination of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) by on-line in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-mass spectrometry (LC-MS). PFOA and PFOS were separated within 10 min by high-performance liquid chromatography using an Inertsil ODS-3 column and 10 mM ammonium acetate/methanol (35/65, v/v) as a mobile phase at a flow rate of 0.25 mL min(-1). Electrospray ionization conditions in the negative ion mode were optimized for MS detection of PFOA and PFOS. The optimum in-tube SPME conditions were 20 draw/eject cycles with a sample size of 40 mu L using a CP-Pora PLOT amine capillary column as the extraction device. The extracted compounds could be desorbed easily from the capillary by passage of the mobile phase, and no carryover was observed. Using the in-tube SPME LC-MS method, good linearity of the calibration curve (r=0.9990 for PFOA, r=0.9982 for PFOS) was obtained in the range of 0.05-5 ng mL(-1) each compound, The detection limits (S/N=3) for PFOA and PFOS were 1.5 and 3.2 pg mL(-1), respectively. The method described here showed about 100-fold higher sensitivity than the direct injection method. The within-day and between-day precisions (relative standard deviations) were below 3.7 and 6.0%, respectively. This method was applied successfully to the analysis of PFOA and PFOS in environmental water samples and to the elution test from a Teflon (R)-coated frying pan without interference peaks. The recoveries of PFOA and PFOS spiked into river samples were above 81%, and PFOA was detected at pg mL(-1) levels in environmental water samples and eluate from the frying pan. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [41] Determination of pesticides in tea by isotope dilution gas chromatography-mass spectrometry coupled with solid-phase microextraction
    Feng, Jie
    Tang, Hua
    Chen, Dazhou
    Wang, Guannan
    Li, Lei
    ANALYTICAL METHODS, 2012, 4 (12) : 4198 - 4203
  • [42] Determination of antifouling compounds in marine sediments by solid-phase microextraction coupled to gas chromatography-mass spectrometry
    Lambropoulou, DA
    Sakkas, VA
    Albanis, TA
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1010 (01) : 1 - 8
  • [43] Determination of Ochratoxin A in wine by packed in-tube solid phase microextraction followed by high performance liquid chromatography coupled to tandem mass spectrometry
    Andrade, Mariane A.
    Lancas, Fernando M.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1493 : 41 - 48
  • [44] In-tube solid-phase microextraction coupled to liquid chromatography (in-tube SPME/LC) analysis of nontricyclic antidepressants in human plasma
    Goncalves Silva, Bruno Jose
    Lancas, Fernando Mauro
    Costa Queiroz, Maria Eugenia
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 181 - 188
  • [45] Graphene oxide based in-tube solid-phase microextraction combined with liquid chromatography tandem mass spectrometry for the determination of triazine herbicides in water
    Tan, Feng
    Zhao, Cong
    Li, Lianjun
    Liu, Min
    He, Xin
    Gao, Jinsuo
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (13) : 2312 - 2319
  • [46] Determination of tributyltin by automated in-tube solid-phase microextraction coupled with HPLC-ES-MS
    Wu, JC
    Mester, Z
    Pawliszyn, J
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (02) : 159 - 165
  • [47] Trace determination of sulfonamides residues in meat with a combination of solid-phase microextraction and liquid chromatography-mass spectrometry
    Lu, Kuan-Hui
    Chen, Chung-Yu
    Lee, Maw-Rong
    TALANTA, 2007, 72 (03) : 1082 - 1087
  • [48] On-fibre solid-phase microextraction coupled to conventional liquid chromatography versus in-tube solid-phase microextraction coupled to capillary liquid chromatography for the screening analysis of triazines in water samples
    Chafer-Pericas, C.
    Herraez-Hernandez, R.
    Campins-Falco, P.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1125 (02) : 159 - 171
  • [49] Development of In-tube solid-phase microextraction/Liquid chromatography/electrospray ionization mass spectrometry for the analysis of mutagenic heterocyclic amines
    H. Kataoka
    J. Pawliszyn
    Chromatographia, 1999, 50 : 532 - 538
  • [50] Determination of perfluorooctane sulfonate, perfluorooctanoate and perfluorooctane sulfonylamide in human plasma by column-switching liquid chromatography-electrospray mass spectrometry coupled with solid-phase extraction
    Inoue, K
    Okada, F
    Ito, R
    Kawaguchi, M
    Okanouchi, N
    Nakazawa, H
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (01): : 49 - 56