Research of measuring accuracy of laser tracker system

被引:2
|
作者
Jianfei, Ouyang [1 ]
Liang Zhiyong [1 ]
Zhang Haixin [1 ]
Yan Yonggang [1 ]
机构
[1] Henan Polytech Univ, Precis Engn Inst, Jiaozuo 454003, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
laser tracker system; Coordinate Measuring Machine; measuring accuracy stability;
D O I
10.1117/12.716187
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
uThis paper presents the achievement of a China NSFC project. The Laser Tracker System (LTS) is a portable 31) large size measuring system. The measuring conditions such as time and temperature can greatly affect the measuring accuracy of LTS. This paper pays a great attention to study how the time and temperature affect the measuring accuracy of LTS. Coordinate Measuring Machine (CMM) is employed as a high-level measuring instrument to validate LTS. The experiments have been done to find how the time and temperature affect the measuring accuracy of LTS. The experiments show the LTS can work well with the highest measuring accuracy just after three-hour warm-up. However, the LTS becomes unstable and the measuring accuracy decreases after 10 hours. The LTS needs calibration and compensation every 10 hours. The experiments show that the measuring error can be up to 29.6 mu m when the measuring temperature is 30.5 degrees C even if the measuring error is less than 5.9 mu m while the temperature is between 20 degrees C and 23.8 degrees C. The research provides a very useful guidance for application of LTS.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Research on Accuracy Analysis of Laser Transmission System Based on Zemax and Matlab
    Chen, Haiping
    Liu, Changchun
    Ye, Haixian
    Xiong, Zhao
    Cao, Tingfen
    FOURTH INTERNATIONAL SYMPOSIUM ON LASER INTERACTION WITH MATTER, 2017, 10173
  • [42] Measuring Method for Long-Distance Dynamic Indication Accuracy of Laser Irradiation System
    Jing Wenbo
    Huang Bingkun
    Cao Genming
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2022, 49 (07):
  • [43] Research on the Laser Tracking System for Measuring Moving Target Based on APD
    Liu Hua
    Miao Yinxiao
    Gao Yue
    REAL-TIME PHOTONIC MEASUREMENTS, DATA MANAGEMENT, AND PROCESSING II, 2016, 10026
  • [44] Research on distance measuring method of laser tracking system and its application
    Xie, Chi
    Zhou, Zhao-Fei
    Cai, Peng
    Zhang, Tao
    Binggong Xuebao/Acta Armamentarii, 2007, 28 (11): : 1377 - 1381
  • [45] THE LASER TRACKER
    Singh, Akshay
    Singh, Monika
    2017 2ND INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2017, : 941 - 944
  • [46] Algorithm for Detecting Volumetric Geometric Accuracy of NC Machine Tool by Laser Tracker
    WANG Jindong
    GUO Junjie
    Chinese Journal of Mechanical Engineering, 2013, (01) : 166 - 175
  • [47] Algorithm for Detecting Volumetric Geometric Accuracy of NC Machine Tool by Laser Tracker
    WANG Jindong
    GUO Junjie
    Chinese Journal of Mechanical Engineering, 2013, 26 (01) : 166 - 175
  • [48] Error analysis of tracking mirror for laser tracker system
    Liu, Wan-Li
    Wang, Zhan-Kui
    Qu, Xing-Hua
    Ouyang, Jian-Fei
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2008, 16 (04): : 585 - 590
  • [49] Real-time laser tracker compensation of a 3-axis positioning system-dynamic accuracy characterization
    Wang, Zheng
    Maropoulos, Paul G.
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2016, 84 (5-8): : 1413 - 1420
  • [50] The laser alignment system for the CMS silicon microstrip tracker
    Wittmer, Bruno
    Adolphi, Roman
    Henke, Michael
    Ostaptchouk, Andrei
    Thomas, Maarten
    Schael, Stefan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 351 - 355