Optimized inside-out magnetic resonance probe for soil moisture measuring in situ

被引:12
|
作者
Shen, Sheng [1 ]
Guo, Pan [2 ]
Wu, Jiamin [1 ]
Ding, Ye [1 ]
Chen, Fangge [1 ]
Meng, Fanqin [1 ]
Xu, Zheng [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] Chongqing Normal Univ, Sch Phys & Elect Engn, Chongqing 401331, Peoples R China
基金
中国国家自然科学基金;
关键词
Inside-out NMR probe; Permanent magnet optimization; RF coil optimization; Soil moisture; NMR; REGION; WATER;
D O I
10.1016/j.jmr.2019.07.052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report a novel inside-out NMR (nuclear magnetic resonance) probe for the measurement of soil moisture. The probe consists of a dumbbell-shape magnet and an opposed-solenoid RF (radio frequency) coil. Optimization methods for the structure of the magnet and RF coil that maximize the SNR (signal-to-noise ratio) of NMR measurements are also described. The dumbbell-shape magnet consists of three cylindrical magnets in series whose magnetic field was calculated with analytic expression deduced by converting magnet to equivalent magnetization current on its cylindrical surface. Based on the analytic expression, a nonlinear optimization mathematical model was built to determine the optimal structure parameters automatically. The opposed-solenoid is a pair of reverse-connected solenoids and used as RF coil on inside-out NMR probe in this work. Its structure-parameter optimization was carried out based on FEM (finite element method) simulation, and UD (uniform design) was applied to increase the optimization efficiency. A prototype was designed and built consisting of a magnet with length of 100 mm and a diameter of 40 mm. An NMR-based soil moisture measuring experiment was conducted by this prototype, with NMR performed using the CPMG (Carr-Purcell-Meiboom-Gill) pulse sequence for soil sample in different moisture content. The T-2 distribution spectrum reveals that there are two compartments of water in the soil sample: free water and bound water. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Feasibility study on prepolarized surface nuclear magnetic resonance for soil moisture measurements
    Hiller, Thomas
    Costabel, Stephan
    Radic, Tino
    Dlugosch, Raphael
    Mueller-Petke, Mike
    VADOSE ZONE JOURNAL, 2021, 20 (05)
  • [42] Measuring moisture gradients in cellulose fibre networks: An application of the magnetic resonance imaging method
    Nilsson, L
    Mansson, S
    Stenstrom, S
    JOURNAL OF PULP AND PAPER SCIENCE, 1996, 22 (02): : J48 - J52
  • [43] LOW RESOLUTION PULSE MAGNETIC-RESONANCE FOR MEASURING MOISTURE IN SELECTED GRAINS AND KERNELS
    TOLLNER, EW
    HUNG, YC
    JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1992, 53 (03): : 195 - 208
  • [44] Development of a small-probe pulsed nuclear magnetic resonance system for measuring magnetic field uniformity
    Kato, S
    Maehata, K
    Ishibashi, K
    Wakuta, Y
    Shintomi, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (03): : 1468 - 1473
  • [45] In situ soil moisture and thermal properties estimated using a dual-probe heat-pulse
    Liu, Jie
    Shi, Bin
    Sun, Meng-Ya
    Yao, Jun-Cheng
    Fang, Ke
    GEODERMA, 2024, 450
  • [46] Using a Complex-Impedance Measuring Instrument to Determine In Situ Soil Unit Weight and Moisture Content
    Meehan, Christopher L.
    Hertz, Jason S.
    GEOTECHNICAL TESTING JOURNAL, 2013, 36 (01): : 119 - 137
  • [47] Measuring Out-of-Time-Order Correlators on a Nuclear Magnetic Resonance Quantum Simulator
    Li, Jun
    Fan, Ruihua
    Wang, Hengyan
    Ye, Bingtian
    Zeng, Bei
    Zhai, Hui
    Peng, Xinhua
    Du, Jiangfeng
    PHYSICAL REVIEW X, 2017, 7 (03):
  • [48] Inside-Out Oriented Choline Phosphate-Based Biomimetic Magnetic Nanomaterials for Precise Recognition and Analysis of C-Reactive Protein
    Chen, Zhiwei
    Zhu, Chendi
    Yang, Jiawen
    Zhang, Mengyun
    Yuan, Jiaming
    Shen, Yuan
    Zhou, Jingwei
    Huang, Hao
    Xu, Dongsheng
    Crommen, Jacques
    Jiang, Zhengjin
    Wang, Qiqin
    ANALYTICAL CHEMISTRY, 2023, 95 (06) : 3532 - 3543
  • [49] An Optimized Integrin α6-Targeted Magnetic Resonance Probe for Molecular Imaging of Hepatocellular Carcinoma in Mice
    Lin, Bing-Quan
    Zhang, Wen-Biao
    Zhao, Jing
    Zhou, Xu-Hui
    Li, Yong-Jiang
    Deng, Jun
    Zhao, Qin
    Fu, Gui
    Xie, Chuan-Miao
    Xu, Yi-Kai
    Feng, Guo-Kai
    JOURNAL OF HEPATOCELLULAR CARCINOMA, 2021, 8 : 645 - 656
  • [50] MEASURING HIGH MOISTURE-CONTENT OF CEREAL-GRAINS BY PULSED NUCLEAR MAGNETIC-RESONANCE
    MILLER, BS
    LEE, MS
    HUGHES, JW
    POMERANZ, Y
    CEREAL CHEMISTRY, 1980, 57 (02) : 126 - 129