Optimized inside-out magnetic resonance probe for soil moisture measuring in situ

被引:12
|
作者
Shen, Sheng [1 ]
Guo, Pan [2 ]
Wu, Jiamin [1 ]
Ding, Ye [1 ]
Chen, Fangge [1 ]
Meng, Fanqin [1 ]
Xu, Zheng [1 ]
机构
[1] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400044, Peoples R China
[2] Chongqing Normal Univ, Sch Phys & Elect Engn, Chongqing 401331, Peoples R China
基金
中国国家自然科学基金;
关键词
Inside-out NMR probe; Permanent magnet optimization; RF coil optimization; Soil moisture; NMR; REGION; WATER;
D O I
10.1016/j.jmr.2019.07.052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report a novel inside-out NMR (nuclear magnetic resonance) probe for the measurement of soil moisture. The probe consists of a dumbbell-shape magnet and an opposed-solenoid RF (radio frequency) coil. Optimization methods for the structure of the magnet and RF coil that maximize the SNR (signal-to-noise ratio) of NMR measurements are also described. The dumbbell-shape magnet consists of three cylindrical magnets in series whose magnetic field was calculated with analytic expression deduced by converting magnet to equivalent magnetization current on its cylindrical surface. Based on the analytic expression, a nonlinear optimization mathematical model was built to determine the optimal structure parameters automatically. The opposed-solenoid is a pair of reverse-connected solenoids and used as RF coil on inside-out NMR probe in this work. Its structure-parameter optimization was carried out based on FEM (finite element method) simulation, and UD (uniform design) was applied to increase the optimization efficiency. A prototype was designed and built consisting of a magnet with length of 100 mm and a diameter of 40 mm. An NMR-based soil moisture measuring experiment was conducted by this prototype, with NMR performed using the CPMG (Carr-Purcell-Meiboom-Gill) pulse sequence for soil sample in different moisture content. The T-2 distribution spectrum reveals that there are two compartments of water in the soil sample: free water and bound water. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A compact magnetic resonance system with inside-out sensor for soil moisture measurement
    Wan, Cai
    He, Wei
    Guo, Pan
    Wu, Jiamin
    He, Yucheng
    Xu, Zheng
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (07)
  • [2] Mini Inside-Out Nuclear Magnetic Resonance Sensor Design for Soil Moisture Measurements
    Wu, Jiamin
    Guo, Pan
    Shen, Sheng
    He, Yucheng
    Huang, Xin
    Xu, Zheng
    SENSORS, 2019, 19 (07):
  • [3] Inside-out NMR probe for portable spectrometry
    Le Bec, Gael
    Raoof, Kosai
    Yonnet, Jean-Paul
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 1538 - +
  • [4] Design of Inside-Out Magnetic Resonance Sensor Based on Coordinate Search Method
    Wu, Jiamin
    Xu, Zheng
    Zhu, Yanhe
    He, Yucheng
    APPLIED MAGNETIC RESONANCE, 2024, 55 (06) : 599 - 613
  • [5] Optimal control technique for magnet design in inside-out nuclear magnetic resonance
    Luong, B
    Goswami, JC
    Sezginer, A
    Davies, D
    IEEE TRANSACTIONS ON MAGNETICS, 2001, 37 (02) : 1015 - 1023
  • [6] A new inside-out nuclear magnetic resonance sensor-three-cylinder array
    Guo, Pan
    He, Wei
    García-Naranjo, Juan C.
    Balcom, Bruce J.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2016, 31 (08): : 96 - 101
  • [7] Rechargeable lithium-ion cell state of charge and defect detection by in-situ inside-out magnetic resonance imaging
    Ilott, Andrew J.
    Mohammadi, Mohaddese
    Schauerman, Christopher M.
    Ganter, Matthew J.
    Jerschow, Alexej
    NATURE COMMUNICATIONS, 2018, 9
  • [8] Rechargeable lithium-ion cell state of charge and defect detection by in-situ inside-out magnetic resonance imaging
    Andrew J. Ilott
    Mohaddese Mohammadi
    Christopher M. Schauerman
    Matthew J. Ganter
    Alexej Jerschow
    Nature Communications, 9
  • [9] A calibrated soil probe for measuring field soil moisture
    Allyn, RB
    SOIL SCIENCE, 1942, 53 (01) : 273 - 285
  • [10] Exploring inside-out Doppler tomography: magnetic cataclysmic variables
    Kotze, E. J.
    Potter, S. B.
    McBride, V. A.
    ASTRONOMY & ASTROPHYSICS, 2016, 595