Effect of outlet water level raising and effluent recirculation on removal efficiency of pilot-scale, horizontal subsurface flow constructed wetlands

被引:34
|
作者
Stefanakis, Alexandros I. [1 ]
Tsihrintzis, Vassilios A. [1 ]
机构
[1] Democritus Univ Thrace, Lab Ecol Engn & Technol, Dept Environm Engn, Sch Engn, GR-67100 Xanthi, Greece
关键词
Constructed wetlands; Horizontal subsurface flow; Effluent recirculation; Water level raising; Temperature; HRT; Organic matter; Nitrogen; Phosphorus; REED BED SYSTEM; NITROGEN REMOVAL; PERFORMANCE; MEDIA;
D O I
10.1016/j.desal.2008.08.008
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Two pilot-scale, horizontal subsurface flow (HSF) constructed wetlands (CWs) were constructed and operated continuously for 3 years, fed with synthetic wastewater. Both wetlands were of rectangular cross-section with dimensions 3.0 m in length and 0.75 in in width. After the first 2 years of operation (period A), two modifications were applied to the wetland units: (1) the outlet water level was raised in the first unit and (2) 50% effluent recirculation was applied to the second unit. Under these two modifications, the two CWs operated for one more year (period B). Water samples were collected every week from the influent, effluent and sampling pipes placed at one-third and two-thirds distance along each unit. The water samples were analysed immediately in the laboratory for BOD5, COD, Total Kjedlahl Nitrogen (TKN), ammonia nitrogen, nitrite, nitrate, total phosphorus (TP) and orthophosphates. The results show that outlet water level raising did not change significantly the performance of the wetland unit, but under this configuration the wetland managed to treat about 15% increased hydraulic and pollutant loads using the same surface area. On the other hand, effluent recirculation negatively affected wetland performance, resulting in a reduction of all pollutant removal rates.
引用
收藏
页码:961 / 976
页数:16
相关论文
共 50 条
  • [41] The Nutrient Removal Ability and Microbial Communities in a Pilot-Scale Horizontal Subsurface Flow Constructed Wetland Fed by Slightly Polluted Lake Water
    Wang, Weigang
    Zhao, Yuhao
    Jiang, Guangmeng
    Wang, Yayi
    WETLANDS, 2020, 40 (06) : 2085 - 2096
  • [42] The Nutrient Removal Ability and Microbial Communities in a Pilot-Scale Horizontal Subsurface Flow Constructed Wetland Fed by Slightly Polluted Lake Water
    Weigang Wang
    Yuhao Zhao
    Guangmeng Jiang
    Yayi Wang
    Wetlands, 2020, 40 : 2085 - 2096
  • [43] Effect of vegetation in pilot-scale horizontal subsurface flow constructed wetlands treating sulphate rich groundwater contaminated with a low and high chlorinated hydrocarbon
    Chen, Zhongbing
    Wu, Shubiao
    Braeckevelt, Mareike
    Paschke, Heidrun
    Kaestner, Matthias
    Moeser, Heinz
    Kuschk, Peter
    CHEMOSPHERE, 2012, 89 (06) : 724 - 731
  • [44] Effect of plants and filter materials on bacteria removal in pilot-scale constructed wetlands
    Vacca, G
    Wand, H
    Nikolausz, M
    Kuschk, P
    Kästner, M
    WATER RESEARCH, 2005, 39 (07) : 1361 - 1373
  • [45] Effect of COD/N ratio on nitrate removal in horizontal subsurface flow constructed wetlands
    Yin, Qi
    Guo, Wenrui
    Wen, Yue
    Zhou, Qi
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON INFORMATION ENGINEERING FOR MECHANICS AND MATERIALS, 2015, 21 : 1758 - 1762
  • [46] Benzotriazole removal mechanisms in pilot-scale constructed wetlands treating cooling tower water
    Wagner, Thomas, V
    Parsons, John R.
    Rijnaarts, Huub H. M.
    de Voogt, Pim
    Langenhoff, Alette A. M.
    JOURNAL OF HAZARDOUS MATERIALS, 2020, 384
  • [47] Effect of HRT and seasons on the performance of pilot-scale horizontal subsurface flow constructed wetland to treat rural wastewater
    Shruthi, R.
    Shivashankara, G. P.
    WATER PRACTICE AND TECHNOLOGY, 2022, 17 (01) : 445 - 455
  • [48] Modeling of Pollutants Removal in Subsurface Vertical Flow and Horizontal Flow Constructed Wetlands
    Dabrowski, Wojciech
    Karolinczak, Beata
    Malinowski, Pawel
    Boruszko, Dariusz
    WATER, 2019, 11 (01)
  • [49] Numerical simulation of phosphorus removal in horizontal subsurface flow constructed wetlands
    Liolios, Konstantinos A.
    Moutsopoulos, Konstantinos N.
    Tsihrintzis, Vassilios A.
    DESALINATION AND WATER TREATMENT, 2015, 56 (05) : 1282 - 1290
  • [50] Effect of operational and design parameters on removal efficiency of pilot-scale FWS constructed wetlands and comparison with HSF systems
    Kotti, Irini P.
    Gikas, Georgios D.
    Tsihrintzis, Vassilios A.
    ECOLOGICAL ENGINEERING, 2010, 36 (07) : 862 - 875