Statistical LOR estimation for a high-resolution dMiCE PET detector

被引:16
|
作者
Champley, Kyle M. [1 ]
Lewellen, Thomas K. [1 ]
MacDonald, Lawrence R. [1 ]
Miyaoka, Robert S. [1 ]
Kinahan, Paul E. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 20期
关键词
WAVELENGTH SHIFTING WLS; DEPTH; READOUT; MODULES; CALIBRATION; DESIGN;
D O I
10.1088/0031-9155/54/20/022
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We develop a statistical line of response (LOR) estimator of the three-dimensional interaction positions of a pair of annihilation photons in a PET detector module with depth of interaction capability. The three-dimensional points of interaction of a coincidence pair of photons within the detector module are estimated by calculation of an expectation of the points of interaction conditioned on the signals measured by the photosensors. This conditional expectation is computed from estimates of the probability density function of the light collection process and a model of the kinetics of photon interactions in the detector module. Our algorithm is capable of handling coincidences where each annihilation photon interacts any number of times within the detector module before being completely absorbed or escaping. In the case of multiple interactions, our algorithm estimates the position of the first interaction for each of the coincidence photons. This LOR estimation algorithm is developed for a high-resolution PET detector capable of providing depth-of-interaction information. Depth of interaction is measured by tailoring the light shared between two adjacent detector elements. These light-sharing crystal pairs are referred to as dMiCE and are being developed in our lab. Each detector element in the prototype system has a 2 x 2 mm(2) cross section and is directly coupled to a micro-pixel avalanche photodiode (MAPD). In this set-up, the distribution of the ratio of light shared between two adjacent detector elements can be expressed as a function of the depth of interaction. Monte Carlo experiments are performed using our LOR estimation algorithm and compared with Anger logic. We show that our LOR estimation algorithm provides a significant improvement over Anger logic under a variety of parameters.
引用
收藏
页码:6369 / 6382
页数:14
相关论文
共 50 条
  • [21] Development of a LGSO detector using a tapered fiber for a high-resolution animal PET
    Yamamoto, S
    Murayama, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1611 - 1614
  • [22] High-resolution image reconstruction for PET using estimated detector response functions
    Tohme, Michel S.
    Qi, Jinyi
    COMPUTATIONAL IMAGING V, 2007, 6498
  • [23] A finely segmented semi-monolithic detector tailored for high-resolution PET
    Kuhl, Yannick
    Mueller, Florian
    Naunheim, Stephan
    Bovelett, Matthias
    Lambertus, Janko
    Schug, David
    Weissler, Bjoern
    Gegenmantel, Eike
    Gebhardt, Pierre
    Schulz, Volkmar
    MEDICAL PHYSICS, 2024, 51 (05) : 3421 - 3436
  • [24] High resolution PET detector.
    Clinthorne, NH
    Park, S
    Wilderman, SJ
    Rogers, WL
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 102P - 103P
  • [25] DEVELOPMENT OF A HIGH-RESOLUTION PET
    YAMASHITA, T
    UCHIDA, H
    OKADA, H
    KURONO, T
    TAKEMORI, T
    WATANABE, M
    SHIMIZU, K
    YOSHIKAWA, E
    OHMURA, T
    SATOH, N
    TANAKA, E
    NOHARA, N
    TOMITANI, T
    YAMAMOTO, M
    MURAYAMA, H
    ENDO, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 594 - 599
  • [26] Development of a High Packing Fraction Detector Module with DOI Measurement Capability for High-Resolution PET
    Almeida, Fernando G.
    Augusto, Silvio
    Barbosa, Jose
    Bugalho, Ricardo
    Carrico, Bruno
    Ferreira, Claudia S.
    Ferreira, Miguel
    Frade, Mario
    Moura, Rui
    Parkhust, Philip
    Ortigao, Catarina
    Pinheiro, Jodo F.
    Rodrigues, Pedro
    Rolo, Ines
    Sa, Diego N.
    Santos, Joaquim C.
    Silva, Jose C.
    Silva, Rui
    Trindade, Andreia
    Varela, Joao
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3072 - +
  • [27] High-resolution PET & high-resolution MRI assessment of hand osteoarthritis
    Tan, A.
    Waller, M.
    Grainger, A.
    Tanner, S.
    Emery, P.
    Benjamin, M.
    McGonagle, D.
    ANNALS OF THE RHEUMATIC DISEASES, 2006, 65 : 21 - 22
  • [28] Statistical dynamic image reconstruction in state-of-the-art high-resolution PET
    Rahmim, A
    Cheng, JC
    Blinder, S
    Camborde, ML
    Sossi, V
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20): : 4887 - 4912
  • [29] A HIGH-RESOLUTION BETA- DETECTOR
    CHARON, Y
    CUZON, JC
    TRICOIRE, H
    VALENTIN, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 748 - 753
  • [30] A miniaturized detector for high-resolution SEMPA
    R. Frömter
    H.P. Oepen
    J. Kirschner
    Applied Physics A, 2003, 76 : 869 - 871