Cavitation Influence on the Operation of a Pumping Station Rig with Variable Speed Pumps

被引:0
|
作者
Ciuc, Petre-Ovidiu [1 ]
Madularea, Remus Alexandra [1 ]
Georgescu, Andrei-Mugur [2 ]
Georgescu, Sanda-Carmen [3 ]
Dunca, Georgiana [3 ]
Bucur, Diana Maria [3 ]
机构
[1] Univ Politehn Bucuresti, Power Engn Doctoral Sch, Bucharest, Romania
[2] Tech Univ Civil Engn Bucharest, Dept Hydraul & Environm Protect, Bucharest, Romania
[3] Univ Politehn Bucuresti, Dept Hydraul Hydraul Machinery & Environm Engn, Bucharest, Romania
关键词
cavitation; NPSH; pumping station; variable speed pump;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To analyse duty points dropdown when centrifugal pumps run with cavitation on their suction side, experiments were conducted on a pumping station (PS) rig, where up to three variable speed driven pumps can run in parallel-coupling. The PS rig is equipped with insufficient measuring devices, like most urban PS-s. The duty points shifting was assessed with respect to pumps' performance curves. A comparison was made with respect to duty points obtained for a regime free of cavitation, after changing the suction pipe (from DN40 to DN63). Global recordings were available, namely a pressure head inside the PS-unit, and the total discharge flow rate at the PS exit. Duty points for each pump were derived using a sensorless control approach and the affinity laws. For the pumps running at nominal speed, the fully cavitating and the incipient cavitating regimes were proved by the NPSH available at the pump inlet, with respect to the NPSH required by the pump. The fully developed cavitation starts way below the 3% head dropdown limit.
引用
收藏
页码:239 / 243
页数:5
相关论文
共 50 条
  • [21] How to Select the Number of Active Pumps during the Operation of a Pumping Station: The Convex Hyperbola Charts
    Martin-Candilejo, Araceli
    Martin-Carrasco, Francisco Javier
    Santillan, David
    WATER, 2021, 13 (11)
  • [22] EXPLORE USE OF VARIABLE SPEED WATER BOOSTER PUMPS .1. VARIABLE SPEED BOOSTER PUMP OPERATION
    GOTTLIEBSON, M
    WATER & WASTES ENGINEERING, 1978, 15 (05): : 63 - &
  • [23] HYDRONIC SYSTEM-DESIGN FOR VARIABLE SPEED VOLUME PUMPING OPERATION
    HEGBERG, RA
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1990, 32 (10): : 31 - &
  • [24] ON THE PUMPING SPEED OF OIL DIFFUSION PUMPS
    PETRALIA, S
    VALDRE, U
    NUOVO CIMENTO, 1959, 12 (06): : 616 - 622
  • [25] PUMPING SPEED OF SPUTTER ION PUMPS
    AUDI, M
    VACUUM, 1988, 38 (8-10) : 669 - 671
  • [26] Experimental test rig designed to analyse pumping station operation controlled by pressure at different key points
    Ciuc, Petre-Ovidiu
    Madularea, Remus Alexandru
    Georgescu, Andrei-Mugur
    Diminescu, Mihaela Amalia
    Georgescu, Sanda-Carmen
    SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT (EENVIRO 2018), 2019, 85
  • [27] Cavitation Conditions of Operation of Vane Pumps.
    Gurov, V.I.
    1978, (10): : 72 - 76
  • [28] Variable speed operation of centrifugal pumps running as turbines. Experimental investigation
    Delgado, J.
    Ferreira, J. P.
    Covas, D. I. C.
    Avellan, F.
    RENEWABLE ENERGY, 2019, 142 : 437 - 450
  • [29] Optimizing target hydraulic head for energy efficient operation of variable speed pumps
    Wu, Z. Y.
    INTEGRATING WATER SYSTEMS, 2010, : 591 - 597
  • [30] Decision Support for the Design and Operation of Variable Speed Pumps in Water Supply Systems
    Nowak, Dimitri
    Krieg, Helene
    Bortz, Michael
    Geil, Christian
    Knapp, Axel
    Roclawski, Harald
    Boehle, Martin
    WATER, 2018, 10 (06)