Percutaneous contrast-enhanced ultrasound for localization and diagnosis of sentinel lymph node in early breast cancer

被引:55
|
作者
Liu, Jian [1 ]
Liu, Xiaoling [1 ]
He, Jiao [2 ]
Gou, Bo [1 ]
Luo, Yujie [2 ]
Deng, Sihui [2 ]
Wen, Hong [2 ]
Zhou, Lin [2 ]
机构
[1] Chengdu Med Coll, Affiliated Hosp 1, Dept Ultrasound, Chengdu 610500, Sichuan, Peoples R China
[2] North Sichuan Med Coll, Affiliated Hosp, Dept Ultrasound, Nanchong 637000, Sichuan, Peoples R China
关键词
INTRADERMAL MICROBUBBLES; IDENTIFICATION; ULTRASONOGRAPHY; METASTASIS; BIOPSY;
D O I
10.1038/s41598-019-49736-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study assessed the efficacy of percutaneous contrast-enhanced ultrasound (CEUS) in localization sentinel lymph node (SLNs) for biopsy and diagnosis of metastatic SLNs in patients with early breast cancer. From January to November 2017, seventy-five patients with early breast cancer confirmed by pathology were enrolled in this study. CEUS was performed after subdermal injection of ultrasound contrast agent (SonoVue, 2.0 ml in total dose) around the areola on the ipsilateral side of the breast. The contrast-enhanced lymphatic vessels and associated SLNs were observed and traced in real time. The lymphatic vessels and SLN were mapped and labeled on the skin surface. Sentinel lymph node biopsy (SLNB) was performed after injection of 2.0 ml methylene blue at same injection site of SonoVue. The accuracy of percutaneous CEUS localization of SLNs was determined compared to blue dye injection technique. The pathological results under blue dye guided biopsy were used as the reference standard to calculate the sensitivity and specificity of CEUS for the diagnosis of SLNs. A total of 163 SLNs obtained through SLNB following methylene blue tracing in 75 patients. There were 116 SLNs identified by percutaneous CEUS. The difference of detection rates between blue dye and CEUS was statistically significant (Z = -2.651, P = 0.008). The identification rate of SLNs by CEUS was 71.17% (116/163). The accuracy of percutaneous CEUS localization of axillary SLNs was 94.67% (71/75) compared to blue dye-guided biopsy. Among the 116 SLNs detected by percutaneous CEUS, pathologic results showed 51 positive SLNs and 65 negative SLNs whiles CEUS findings indicated 83 positive SLNs and 33 negative SLNs. Only 50 of 83 SLNs had metastasis on pathology, while 33 were detected as false positive. The sensitivity and specificity of CEUS for the diagnosis of metastatic SLN was 98.04%(50/51) and 49.23%(32/65), respectively. Percutaneous CEUS can be used as an effective method to localize the SLNs for guiding SLNB. This method has excellent sensitivity for identifying the SLNs but lower specificity for detecting metastatic SLNs in patients with early stage breast cancer.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Identification of Sentinel Lymph Nodes Using Contrast-Enhanced Ultrasound in Breast Cancer
    Saidha N.K.
    Aggarwal R.
    Sen A.
    Indian Journal of Surgical Oncology, 2018, 9 (3) : 355 - 361
  • [22] Preoperative Contrast-Enhanced Ultrasound (CEUS) Combined with 125I Seeds Localization in Sentinel Lymph Node Biopsy for Breast Cancer
    Zhou, Pengpeng
    Zheng, Weizhen
    Liu, Yanbing
    Wang, Yongsheng
    CANCER MANAGEMENT AND RESEARCH, 2021, 13 : 1853 - 1860
  • [24] Percutaneous and intravenous contrast material injection in contrast-enhanced ultrasound for sentinel lymph node evaluation in patients with breast cancer: importance of discussing difference in purposes
    Naoko Mori
    Breast Cancer Research and Treatment, 2024, 203 : 629 - 630
  • [25] Combining Contrast-Enhanced Ultrasound with Methylene Blue for Detection of Sentinel Lymph Nodes in Early Breast Cancer
    Zhang, Jie
    Zhou, Tong-Tong
    Yang, Meng
    Zhang, Bo
    Liu, Jun
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2025, 86 (02)
  • [26] The value of the improved percutaneous and intravenous contrast-enhanced ultrasound diagnostic classification in sentinel lymph nodes of breast cancer
    Huang, Caixin
    Luo, Jia
    Zhen, Tiantian
    Shan, Zhen
    Li, Jiaping
    Ma, Qingmei
    Wei, Laina
    Liang, Jinyu
    Xie, Xiaoyan
    Zheng, Yanling
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (03) : 2391 - 2404
  • [27] Sentinel lymph node localization in early breast cancer
    Gulec, SA
    Moffat, FL
    Carroll, RG
    Serafini, AN
    Sfakianakis, GN
    Allen, L
    Boggs, J
    Escobedo, D
    Pruett, CA
    Gupta, A
    Livingstone, AS
    Krag, DN
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (08) : 1388 - 1393
  • [28] Contrast-enhanced ultrasound-guided sentinel lymph node biopsy in early-stage breast cancer: a prospective cohort study
    Qiuxia Cui
    Li Dai
    Jialu Li
    Yang Shen
    Huijiang Tao
    Xiaofeng Zhou
    Jialei Xue
    World Journal of Surgical Oncology, 21
  • [29] Contrast-enhanced ultrasound-guided sentinel lymph node biopsy in early-stage breast cancer: a prospective cohort study
    Cui, Qiuxia
    Dai, Li
    Li, Jialu
    Shen, Yang
    Tao, Huijiang
    Zhou, Xiaofeng
    Xue, Jialei
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2023, 21 (01)
  • [30] Intradermal microbubbles and contrast-enhanced ultrasound (CEUS) is a feasible approach for sentinel lymph node identification in early-stage breast cancer
    Xie, Fei
    Zhang, Dongjie
    Cheng, Lin
    Yu, Lei
    Yang, Li
    Tong, Fuzhong
    Liu, Hongjun
    Wang, Shu
    Wang, Shan
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2015, 13