Characterization of penumbra sharpening and scattering by adaptive aperture for a compact pencil beam scanning proton therapy system

被引:14
|
作者
Grewal, Hardev S. [1 ,2 ]
Ahmad, Salahuddin [1 ]
Jin, Hosang [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Dept Radiat Oncol, 800 NE 10th St SCC L100, Oklahoma City, OK 73104 USA
[2] Oklahoma Proton Ctr, 5901 W Mem Rd, Oklahoma City, OK 73142 USA
关键词
adaptive aperture; compact proton therapy system; lateral penumbra; pencil beam scanning;
D O I
10.1002/mp.14771
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To quantitatively access penumbra sharpening and scattering by adaptive aperture (AA) under various beam conditions and clinical cases for a Mevion S250i compact pencil beam scanning proton therapy system. Methods First, in-air measurements were performed using a scintillation detector for single spot profile and lateral penumbra for five square field sizes (3 x 3 to 18 x 18 cm(2)), three energies (33.04, 147.36, and 227.16 MeV), and three snout positions (5, 15, and 33.6 cm) with Open and AA field. Second, treatment plans were generated in RayStation treatment planning system (TPS) for various combination of target size (3- and 10-cm cube), target depth (5, 10, and 15 cm) and air gap (5-20 cm) for both Open and AA field. These plans were delivered to EDR2 films in the solid water and penumbra reduction by AA was quantified. Third, the effect of the AA scattered protons on the surface dose was studied at 5 mm depth by EDR2 film and the RayStation TPS computation. Finally, dosimetric advantage of AA over Open field was studied for five brain and five prostate cases using the TPS simulation. Results The spot size changed dramatically from 3.8 mm at proton beam energy of 227.15 MeV to 29.4 mm at energy 33.04 MeV. In-air measurements showed that AA substantially reduced the lateral penumbra by 30% to 60%. The EDR2 film measurements in solid water presented the maximum penumbra reduction of 10 to 14 mm depending on the target size. The maximum increase of 25% in field edge dose at 5 mm depth as compared to central axis was observed. The substantial penumbra reduction by AA produced less dose to critical structures for all the prostate and brain cases. Conclusions Adaptive aperture sharpens the penumbra by factor of two to three depending upon the beam condition. The absolute penumbra reduction with AA was more noticeable for shallower target, smaller target, and larger air gap. The AA-scattered protons contributed to increase in surface dose. Clinically, AA reduced the doses to critical structures.
引用
收藏
页码:1508 / 1519
页数:12
相关论文
共 50 条
  • [31] Utilizing collimated aperture with proton pencil beam scanning (PBS) for stereotactic radiotherapy
    Chou, Chen-Yu
    Tsai, Tsung-Shiau
    Huang, Hsiao-Chieh
    Wang, Jiun-Jie
    Lee, Shen-Hao
    Hsu, Shih-Ming
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (07):
  • [32] Effective Treatment Plan Integrity Verification for Passive Scattering and Pencil Beam Scanning Proton Therapy
    Zhang, Y.
    Ho, M.
    Liu, C.
    Liang, X.
    Johnson, P.
    Park, J.
    Artz, M.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [33] Dosimetric Comparison of Pencil Beam Scanning Proton Plans with Different Aperture Modes
    Yuan, Y.
    DeBlois, D.
    Chen, Y.
    Frame, C.
    Pang, D.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [34] Determination of surface dose in pencil beam scanning proton therapy
    Kern, A.
    Baeumer, C.
    Kroeninger, K.
    Mertens, L.
    Timmermann, B.
    Walbersloh, J.
    Wulff, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S483 - S483
  • [35] Pencil beam scanning proton therapy for pediatric intracranial ependymoma
    Ares, Carmen
    Albertini, Francesca
    Frei-Welte, Martina
    Bolsi, Alessandra
    Grotzer, Michael A.
    Goitein, Gudrun
    Weber, Damien C.
    JOURNAL OF NEURO-ONCOLOGY, 2016, 128 (01) : 137 - 145
  • [36] Proton Pencil Beam Scanning for Rectal Cancer Radiation Therapy
    Kiely, J. P. Blanco
    White, B. M.
    Plastaras, J. P.
    Ben-Josef, E.
    Varman, C.
    Tang, S.
    Tochner, Z. A.
    Metz, J. M.
    Both, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E159 - E159
  • [37] Pencil beam scanning proton therapy for pediatric intracranial ependymoma
    Carmen Ares
    Francesca Albertini
    Martina Frei-Welte
    Alessandra Bolsi
    Michael A. Grotzer
    Gudrun Goitein
    Damien C. Weber
    Journal of Neuro-Oncology, 2016, 128 : 137 - 145
  • [38] Pencil Beam Proton Flash Therapy, the challenge of scanning.
    Pin, A.
    Hotoiu, L.
    Deffet, S.
    Sterpin, E.
    Labarbe, R.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S747 - S748
  • [39] Clinical Implementation of Pencil Beam Scanning (PBS) Proton Therapy
    Dong, Lei
    Dong, L.
    Zhu, X.
    Pankuch, M.
    Dong, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3031 - 3032
  • [40] Pencil Beam Scanning Proton Therapy in the Treatment of Rectal Cancer
    Dionisi, F.
    Batra, S.
    Kirk, M.
    Both, S.
    Vennarini, S.
    McDonough, J.
    Metz, J. M.
    Plastaras, J. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S341 - S342