Differentiation of heroin and cocaine using dual-energy CT-an experimental study

被引:12
|
作者
Grimm, Jochen [1 ,2 ,3 ,4 ]
Wudy, Ramona [1 ]
Ziegeler, Edvard [1 ]
Wirth, Stefan [1 ]
Uhl, Michael [5 ]
Reiser, Maximilian F. [1 ]
Scherr, Michael [1 ]
机构
[1] Ludwig Maximilians Univ Hosp Munich, Inst Clin Radiol, D-80336 Munich, Germany
[2] Univ Lausanne Hosp, Dept Med Radiol, CH-1011 Lausanne, Switzerland
[3] Univ Lausanne, CH-1011 Lausanne, Switzerland
[4] Ctr Legal Med Lausanne & Geneva, CH-1011 Lausanne, Switzerland
[5] Bavarian State Criminal Police Off, D-80636 Munich, Germany
关键词
Body packing; Dual-energy CT; Dual-energy index; Material differentiation; Illicit drugs; DOSE COMPUTED-TOMOGRAPHY; BODY-PACKING; PACKERS; RADIOGRAPHY; STUFFERS; PUSHERS; SURGERY; DRUGS;
D O I
10.1007/s00414-014-0980-6
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
To evaluate if heroin and cocaine can be distinguished using dual-energy CT. Twenty samples of heroin and cocaine at different concentrations and standardized compression (SC) were scanned in dual-energy mode on a newest generation Dual Energy 64-row MDCT scanner. CT number, spectral graphs, and dual-energy index (DEI) were evaluated. Results were prospectively tested on six original samples from a body packer. Wilcoxon's test was used for statistical evaluation. Values are given as median and range. Under SC, the CT number of cocaine samples (-29.87 Hounsfield unit (HU) [-125.85; 16.16 HU]) was higher than the CT number of heroin samples (-184.37 HU [-199.81; -159.25 HU]; p < 0.01). Slope of spectral curves for cocaine was -2.36 HU/keV [-7.15; -0.67 HU/keV], and for heroin, 1.75 HU/keV [1.28; 2.5 HU/keV] (p < 0.01). DEI was 0.0352 [0.0081; 0.0528] for cocaine and significantly higher than for heroin samples (-0.0127 [-0.0097; -0.0159]; p < 0.001). While CT number was inconclusive, all six original packs were correctly classified after evaluation of the spectral curve and DEI. In contrast to the CT number, slope of the spectral curve and DEI were independent of concentration and compression. The slope of the spectral curve and the DEI from dual-energy CT data can be used to distinguish heroin and cocaine in vitro; these results are independent of compression and concentration in the measured range.
引用
收藏
页码:475 / 482
页数:8
相关论文
共 50 条
  • [21] Accuracy of iodine removal using dual-energy CT with or without a tin filter: an experimental phantom study
    Kawai, Tatsuya
    Takeuchi, Mitsuru
    Hara, Masaki
    Ohashi, Kazuya
    Suzuki, Hirochika
    Yamada, Kiyotaka
    Sugimura, Yuya
    Shibamoto, Yuta
    ACTA RADIOLOGICA, 2013, 54 (08) : 954 - 960
  • [22] Differentiation of malignant cervical lymphadenopathy by dual-energy CT: a preliminary analysis
    Yang, Liang
    Luo, Dehong
    Li, Lin
    Zhao, Yanfeng
    Lin, Meng
    Guo, Wei
    Zhou, Chunwu
    SCIENTIFIC REPORTS, 2016, 6
  • [23] Dual-energy CT of the abdomen
    Desiree E. Morgan
    Abdominal Imaging, 2014, 39 : 108 - 134
  • [24] Dual-energy CT of the abdomen
    Morgan, Desiree E.
    ABDOMINAL IMAGING, 2014, 39 (01): : 108 - 134
  • [25] Differentiation of malignant cervical lymphadenopathy by dual-energy CT: a preliminary analysis
    Liang Yang
    Dehong Luo
    Lin Li
    Yanfeng Zhao
    Meng Lin
    Wei Guo
    Chunwu Zhou
    Scientific Reports, 6
  • [26] Dual-Energy CT of the Pancreas
    Mastrodicasa, Domenico
    Delli Pizzi, Andrea
    Patel, Bhavik Natvar
    SEMINARS IN ULTRASOUND CT AND MRI, 2019, 40 (06) : 509 - 514
  • [27] Dual-Energy CT of the Lung
    Lu, Guang Ming
    Zhao, Yan'E
    Zhang, Long Jiang
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S40 - S53
  • [28] Nonuniqueness in dual-energy CT
    Levine, Zachary H.
    MEDICAL PHYSICS, 2017, 44 (09) : E202 - E206
  • [29] Dual-Energy CT of the Heart
    Vliegenthart, Rozemarijn
    Pelgrim, Gert Jan
    Ebersberger, Ullrich
    Rowe, Garrett W.
    Oudkerk, Matthijs
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S54 - S63
  • [30] Using Dual-Energy CT for Painful Hip Arthroplasties
    Lutz, Amelie M.
    RADIOLOGY, 2021, 300 (03) : 650 - 651