Aortic dual-energy CT angiography with low contrast medium injection rate

被引:12
|
作者
Liu, Jie [1 ]
Lv, Pei-Jie [1 ]
Wu, Runze [1 ]
Zhang, Yong-Gao [1 ]
Hu, Li-Li [1 ]
Hou, Ping [1 ]
Gao, Jian-Bo [1 ]
机构
[1] Zhengzhou Univ, Hosp 1, Dept Radiol, Zhengzhou 450052, Henan, Peoples R China
关键词
Dual-energy CT; contrast medium; aortic angiography; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; IMAGE QUALITY; ABDOMINAL CT; BONE REMOVAL; ENHANCEMENT; IODINE;
D O I
10.3233/XST-140454
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The contrast medium (CM) induced nephropathy required new CT imaging protocol. This study evaluated the feasibility of low contrast medium (CM) volume and injection flow using aortic dual-energy CT (DECT) angiography with non-linear blending technique. Sixty patients were randomly assigned to two groups: control group (n = 30), single-energy CT 70 ml CM at injection rate of 5 ml/s; study group (n = 30), DECT mode, 0.5 ml per kg of patient weight CM at injection rate = (weight x 0.5 ml/kg)/(4 + scan time). Non-linear blending technique was used for dual-energy images. Mean attention, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of aorta were compared. The level of visible renal artery branches was scored. There was no significant difference between the two groups in the mean aortic attention, SNR and CNR (all P > 0.05). Significant difference was showed in CM injection rate (p < 0.001) and volume (P < 0.001). The renal artery score had no statistically significant difference (P = 0.771). Compared conventional scan and CM injection protocol, DECT with non-linear blending technique maintained the image quality of aortic CT angiography with reduced CM volume and flow rate, which could reduce the risks associated with CM injection.
引用
收藏
页码:689 / 696
页数:8
相关论文
共 50 条
  • [31] Subtraction CT angiography in head and neck with low radiation and contrast dose dual-energy spectral CT using rapid kV-switching technique
    Ma, Guangming
    Yu, Yong
    Duan, Haifeng
    Dou, Yuequn
    Jia, Yongjun
    Zhang, Xirong
    Yang, Chuangbo
    Chen, Xiaoxia
    Han, Dong
    Guo, Changyi
    He, Taiping
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1086):
  • [32] Dual energy CT angiography: pros and cons of dual-energy metal artifact reduction algorithm in patients after endovascular aortic repair
    Johannes Boos
    Jieming Fang
    Benedikt H. Heidinger
    Vassilios Raptopoulos
    Olga R. Brook
    Abdominal Radiology, 2017, 42 : 749 - 758
  • [33] Dual energy CT angiography: pros and cons of dual-energy metal artifact reduction algorithm in patients after endovascular aortic repair
    Boos, Johannes
    Fang, Jieming
    Heidinger, Benedikt H.
    Raptopoulos, Vassilios
    Brook, Olga R.
    ABDOMINAL RADIOLOGY, 2017, 42 (03) : 749 - 758
  • [34] Validation of renal perfusion with multidetector CT scanner and low rate contrast medium injection
    Lemoine, S.
    Papillard, M.
    Belloi, A.
    Rognant, N.
    Fouque, D.
    Laville, M.
    Rouviere, O.
    Juillard, L.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2011, 25 : 4 - 4
  • [35] Halved contrast medium dose in lower limb dual-energy computed tomography angiography—a randomized controlled trial
    Cathrine Helgestad Kristiansen
    Owen Thomas
    Thien Trung Tran
    Sumit Roy
    Dan Levi Hykkerud
    Audun Sanderud
    Jonn Terje Geitung
    Peter M. Lauritzen
    European Radiology, 2023, 33 : 6033 - 6044
  • [36] In Vivo Differentiation of Complementary Contrast Media at Dual-Energy CT
    Mongan, John
    Rathnayake, Samira
    Fu, Yanjun
    Wang, Runtang
    Jones, Ella F.
    Gao, Dong-Wei
    Yeh, Benjamin M.
    RADIOLOGY, 2012, 265 (01) : 267 - 272
  • [37] Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study
    Jia Wang
    Mingliang Qu
    Xinhui Duan
    Naoki Takahashi
    Akira Kawashima
    Shuai Leng
    Cynthia H. McCollough
    European Radiology, 2012, 22 : 2589 - 2596
  • [38] Reducing Radiation Dose and Contrast Medium Volume With Application of Dual-Energy CT in Children and Young Adults
    Tabari, Azadeh
    Gee, Michael S.
    Singh, Ramandeep
    Lim, Ruth
    Nimkin, Katherine
    Primak, Andrew
    Schmidt, Bernhard
    Kalra, Mannudeep K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (06) : 1199 - 1205
  • [39] Influence of contrast medium on tophus detection using dual-energy CT: phantom study and clinical illustration
    Kotlyarov, Maximilian
    Mews, Jurgen
    Ulas, Sevtap Tugce
    Ziegeler, Katharina
    Hamm, Bernd
    Diekhoff, Torsten
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [40] Application of dual-energy CT with prospective ECG-gating in cardiac CT angiography for children: Radiation and contrast agent dose
    Xie, Mingye
    Wang, Haoru
    Tang, Shilong
    Chen, Mingjing
    Li, Ting
    He, Ling
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 170