Assessment of coronary artery aneurysms in paediatric patients with Kawasaki disease by multidetector row CT angiography: feasibility and comparison with 2D echocardiography

被引:47
|
作者
Chu, Winnie C. W.
Mok, Geoffrey C. F.
Lam, Wynnie W. M.
Yam, Manching
Sung, Rita Y. T.
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Diagnost Radiol & Organ Imaging, Fac Med, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Pediatr, Hong Kong, Peoples R China
关键词
coronary artery; aneurysms; Kawasaki disease; MDCT angiography; children;
D O I
10.1007/s00247-006-0281-4
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Transthoracic ECHO is the locally accepted method for coronary surveillance of patients with Kawasaki disease but it may have limited visualization in the older child. Objective: To assess the feasibility of multidetector CT (MDCT) angiography in the follow-up of coronary artery aneurysms in children with previous Kawasaki disease. Materials and methods: Six children (5 boys, 1 girl; mean age 11.5 years) with known Kawasaki disease and coronary artery involvement underwent CT coronary angiography using 16-detector MDCT. The visualized lengths and diameter of all coronary segments were measured. The number, size and location of coronary artery aneurysms were recorded and compared with recent ECHO. Results: Twelve coronary artery aneurysms (seven saccular, five fusiform) were identified by MDCT angiography. One saccular aneurysm at the junction of the distal right coronary artery and posterior descending artery was not detected by ECHO while the remaining six in proximal segments were detected by both modalities. Two of five fusiform aneurysms were not detected by ECHO due to their small sizes. Excellent agreement was found between CT and ECHO for maximal diameter and length of the visualized aneurysms. Conclusions: MDCT angiography accurately defines coronary artery aneurysms. It is more sensitive for detecting aneurysms at distal coronary segments and fusiform aneurysms of small size.
引用
收藏
页码:1148 / 1153
页数:6
相关论文
共 50 条
  • [31] Costs and clinical outcomes after coronary multidetector CT angiography in patients without known coronary artery disease: Comparison to myocardial perfusion SPECT
    Min, James K.
    Kang, Ning
    Shaw, Leslee J.
    Devereux, Richard B.
    Robinson, Matthew
    Lin, Fay
    Legorreta, Antonio P.
    Gilmore, Amanda
    RADIOLOGY, 2008, 249 (01) : 62 - 70
  • [32] 2d strain can predict significant coronary artery disease in patients with a normal echocardiography
    Karima, Taamallah
    Guebsi, M.
    Ataoui, S.
    Talhaoui, A.
    Bennooman, A.
    Raddaoui, H.
    Hajlaoui, N.
    Lahidheb, D.
    Fehri, W.
    EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2020, 19 (1_SUPPL) : S51 - S51
  • [33] Multiple Giant Coronary Artery Aneurysms Due to Kawasaki Disease: Electrocardiogram-Gated 64-Slice Multidetector Row Computed Tomography Findings
    Kwon, Se Hwan
    Oh, Joo Hyeong
    Han, Mi-Young
    PEDIATRIC CARDIOLOGY, 2009, 30 (01) : 89 - 90
  • [34] Multiple Giant Coronary Artery Aneurysms Due to Kawasaki Disease: Electrocardiogram-Gated 64-Slice Multidetector Row Computed Tomography Findings
    Se Hwan Kwon
    Joo Hyeong Oh
    Mi-Young Han
    Pediatric Cardiology, 2009, 30 : 89 - 90
  • [35] Correction to: Coronary artery assessment in Kawasaki disease with dual-source CT angiography to uncover vascular pathology
    D. van Stijn
    R. N. Planken
    M. Groenink
    G. J. Streekstra
    T. W. Kuijpers
    I. M. Kuipers
    European Radiology, 2022, 32 : 2134 - 2134
  • [36] Long-term changes in coronary artery aneurysms in patients with Kawasaki disease - Comparison of therapeutic regimens
    Onouchi, Z
    Hamaoka, K
    Sakata, K
    Ozawa, S
    Shiraishi, I
    Itoi, T
    Kiyosawa, N
    CIRCULATION JOURNAL, 2005, 69 (03) : 265 - 272
  • [37] Coronary Atherosclerosis and Coronary Artery Disease in Patients With Obstructive Sleep Apnea: Assessment at Coronary CT Angiography
    Abro, Joseph
    Armstrong, Andrew
    Parker, Adrian
    Gebregziabher, Mulugeta
    Schoepf, U. Joseph
    Sharma, Sunil
    CIRCULATION, 2009, 120 (18) : S302 - S302
  • [38] The Complementary Relationship Between Echocardiography and Multi-Slice Spiral CT Coronary Angiography in the Diagnosis of Coronary Artery Thrombosis in Children With Kawasaki Disease
    Xu, Yun-ming
    Chu, Yan-qiu
    Li, Xue-mei
    Wang, Ce
    Ma, Quan-mei
    Yu, Xiao-na
    Yu, Xian-yi
    Chen, Rui
    Xing, Yan-lin
    Yu, Xue-xin
    Sun, Le
    Cui, Xiao-zhe
    Wang, Hong
    FRONTIERS IN PEDIATRICS, 2021, 9
  • [39] Assessment of myocardial ischemia during dobutamine stress echocardiography by 2D speckle tracking in patients with suspect coronary artery disease
    Eder, V.
    Nesser, H. -J.
    Aichinger, J.
    Ebner, C.
    Sturmberger, T.
    WIENER KLINISCHE WOCHENSCHRIFT, 2014, 126 : S87 - S88
  • [40] Comparison of real-time tri-plane and conventional 2D dobutamine stress echocardiography for the assessment of coronary artery disease
    Eroglu, Elif
    D'hooge, Jan
    Herbots, Lieven
    Thijs, Daisy
    Dubois, Christophe
    Sinnaeve, Peter
    Dens, Joseph
    Vanhaecke, Johan
    Rademakers, Frank
    EUROPEAN HEART JOURNAL, 2006, 27 (14) : 1719 - 1724