Enhancing the limit of detection for comprehensive two-dimensional gas chromatography (GC x GC) using bilinear chemometric analysis

被引:0
|
作者
Fraga, CG [1 ]
Prazen, BJ [1 ]
Synovec, RE [1 ]
机构
[1] Univ Washington, Dept Chem, Ctr Proc Analyt Chem, Seattle, WA 98195 USA
来源
关键词
bilinear signal enhancement; two-dimensional comprehensive gas chromatography; chemometrics; GC; GRAM;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The chemometric method referred to as the generalized rank annihilation method (GRAM) is used to improve the precision, accuracy, and resolution of comprehensive two-dimensional gas chromatography (GC x GC) data. Because GC x GC signals follow a bilinear structure, GC x GC signals can be readily extracted from noise by chemometric techniques such as GRAM. This resulting improvement in signal-to-noise ratio (S/N) and detectability is referred to as bilinear signal enhancement. Here, GRAM uses bilinear signal enhancement on both resolved and unresolved GC x GC peaks that initially have a low SIN in the original GC x GC data. In this work, the chemometric method of GRAM is compared to two traditional peak integration methods for quantifying GC x GC analyte signals, One integration method uses a threshold to determine the signal of a peak of interest. With this integration method only those data points above the limit of detection and within a selected area are integrated to produce the total analyte signal for calibration and quantification. The other integration method evaluated did not employ a threshold, and simply summed all the data points in a selected region to obtain a total analyte signal, Substantial improvements in quantification precision, accuracy, and limit of detection are obtained by using GRAM, as compared to,when either peak integration method is applied. In addition, the GRAM results are found to be more accurate than results obtained by peak integration, because GRAM more effectively corrects for the slight baseline offset remaining after the background subtraction of data. In the case of a 2.7-ppm propylbenzene synthetic sample the quantification result with GRAM is 2.6 times more precise and 4.2 times more accurate than the integration method without a threshold, and 18 times more accurate than the integration method with a threshold. The limit of detection for propylbenzene was 0.6 ppm (parts per million by mass) using GRAM, without implementing any sample preconcentration prior to injection. GRAM is also demonstrated as a means to resolve overlapped signals, while enhancing the S/N. Four alkyl benzene signals of low S/N which were not resolved by GC x GC are mathematically resolved and quantified.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
  • [41] Second-order chemometric standardization for high-speed hyphenated gas chromatography: Analysis of GC/MS and comprehensive GC X GC data
    Prazen, Bryan J.
    Bruckner, Carsten A.
    Synovec, Robert E.
    Kowalski, Bruce R.
    Journal of Microcolumn Separations, 11 (02): : 97 - 107
  • [42] Characterization of the volatile compounds of huangjiu using comprehensive two-dimensional gas chromatography coupled to time of flight mass spectrometry (GC x GC-TOFMS)
    Zhou, Zhilei
    Ji, Zhongwei
    Liu, Shuangping
    Han, Xiao
    Zheng, Fuping
    Mao, Jian
    JOURNAL OF FOOD PROCESSING AND PRESERVATION, 2019, 43 (10)
  • [43] GC x GC temperature programming requirements to produce bilinear data for chemometric analysis
    Johnson, KJ
    Prazen, BJ
    Olund, RK
    Synovec, RE
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (5-6) : 297 - 303
  • [44] Comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (GC x GC-TOFMS) for drug screening and confirmation
    Song, SM
    Marriott, P
    Kotsos, A
    Drummer, OH
    Wynne, P
    FORENSIC SCIENCE INTERNATIONAL, 2004, 143 (2-3) : 87 - 101
  • [45] Comprehensive two-dimensional gas chromatography (GC x GC) of atropisomeric PCBs, combining a narrow bore β-cyclodextrin column and a liquid crystal column
    Harju, M
    Haglund, P
    JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (07) : 300 - 305
  • [46] Exploring the Complexity of Two Iconic Crude Oil Spills in the Gulf of Mexico (Ixtoc I and Deepwater Horizon) Using Comprehensive Two-Dimensional Gas Chromatography (GC x GC)
    Nelson, Robert K.
    Gosselin, Kelsey M.
    Hollander, David J.
    Murawski, Steven A.
    Gracia, Adolfo
    Reddy, Christopher M.
    Radovic, Jagos R.
    ENERGY & FUELS, 2019, 33 (05) : 3925 - 3933
  • [47] Comprehensive Two-Dimensional Gas Chromatography Hyphenated with a Vacuum Ultraviolet Spectrometer To Analyze Diesel-A Three-Dimensional Separation (GC x GC x VUV) Approach
    Wang, Frank Cheng-Yu
    ENERGY & FUELS, 2020, 34 (07) : 8012 - 8017
  • [48] Characterisation of middle-distillates by comprehensive two-dimensional gas chromatography (GC x GC):: A powerful alternative for performing various standard analysis of middle-distillates
    Vendeuvre, C
    Ruiz-Guerrero, R
    Bertoncini, F
    Duval, L
    Thiébaut, D
    Hennion, MC
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1086 (1-2) : 21 - 28
  • [49] Characterization of gaseous mixtures of organic compounds with dual-secondary column comprehensive two-dimensional gas chromatography (GC x 2GC)
    Seeley, JV
    Kramp, FJ
    Sharpe, KS
    Seeley, SK
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (1-2) : 53 - 59
  • [50] Compositional Characterization of a Hydrothermal Liquefaction (HTL) Bio-Oil Mid-Distillate by Comprehensive Two-Dimensional Gas Chromatography (GC x GC)
    Wang, Frank Cheng-Yu
    ENERGY & FUELS, 2022, 36 (24) : 14976 - 14985