Chronometric vs. Structural Hypercoagulability

被引:1
|
作者
Delianu, Carmen [1 ,2 ]
Moscalu, Mihaela [3 ]
Hurjui, Loredana Liliana [2 ,4 ]
Tarniceriu, Claudia Cristina [5 ,6 ]
Badulescu, Oana-Viola [4 ,6 ]
Lozneanu, Ludmila [7 ,8 ]
Hurjui, Ion [9 ]
Goriuc, Ancuta [1 ]
Surlari, Zinovia [10 ]
Foia, Liliana [1 ,11 ]
机构
[1] Grigore T Popa Univ Med & Pharm, Dept Biochem, Iasi 700115, Romania
[2] Sf Spiridon Cty Clin Emergency Hosp, Hematol Dept, Cent Clin Lab, Iasi 700111, Romania
[3] Grigore T Popa Univ Med & Pharm, Dept Prevent Med & Interdisciplinar, Iasi 700115, Romania
[4] Grigore T Popa Univ Med & Pharm, Discipline Physiol, Dept Morphofunct Sci 2, Iasi 700115, Romania
[5] Grigore T Popa Univ Med & Pharm, Discipline Anat, Dept Morphofunct Sci 1, Univ Str 16, Iasi 700115, Romania
[6] Sf Spiridon Cty Clin Emergency Hosp, Hematol Clin, Iasi 700111, Romania
[7] Grigore T Popa Univ Med & Pharm, Discipline Histol, Dept Morphofunct Sci 1, Univ Str 16, Iasi 700115, Romania
[8] Sf Spiridon Emergency Cty Hosp, Dept Pathol, Iasi 700111, Romania
[9] Grigore T Popa Univ Med & Pharm, Discipline Biophys, Dept Morphofunct Sci 2, Iasi 700115, Romania
[10] Grigore T Popa Univ Med & Pharm, Dept Odontol & Parodontol, Univ Str 16, Iasi 700115, Romania
[11] Sf Spiridon Cty Clin Emergency Hosp, Biochem Dept, Cent Clin Lab, Iasi 700111, Romania
来源
MEDICINA-LITHUANIA | 2021年 / 57卷 / 01期
关键词
stasis; endothelial damage; tissue factor; false hypercoagulability; chronometric; DIAGNOSTIC HEMOSTASIS LABORATORIES; FACTOR INHIBITORS; BLOOD COLLECTION; VARIABILITY; COAGULATION; ASSAYS; TIME;
D O I
10.3390/medicina57010013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Prolonged tourniquet stasis induced by venepuncture can lead to the release of the plasma of cell lysis products, as well as tissue factor (TF), impairing the quality of coagulation test results. The accidental presence of TF in vitro can trigger the coagulation mechanism, generating a false decrease in prothrombin time (PT). Background and Objectives: Identification of short PT tests below the normal reference value that could suggest a situation of hypercoagulability. The study aimed to compare the results of the shortened PT tests at their first determination with the eventual correction following duplication of the analysis from the same sample. Materials and methods: Identification of the shortened PT tests has been carried out for a period of 4 months, upon 544 coagulation samples referred to the Hematology department of Sf. Spiridon County Clinical Emergency Hospital from Iasi, Romania. Results: Out of the 544 samples of which the results indicated a state of hypercoagulability, by repeating the determination from the same sample, for 200 (36.76%) PT tests (p = 0.001) the value was corrected, falling within the normal reference range. For 344 (63.24%) tests, the results suggested a situation of hypercoagulability. Conclusions: In order to guarantee the highest quality of the laboratory services, a proper interpretation and report of the patients' results must be congruent and harmoniously associated to the actual clinical condition of the patient. Duplication of the PT determination from the same sample would exclude situations of false hypercoagulability and would provide significant improvement for the patient's safety.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 50 条
  • [31] Searching the Cambridge Structural Database for solvated vs. unsolvated pairs
    van de Streek, Jacco
    Motherwell, Sam
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2006, 62 : S75 - S75
  • [32] Quantum atomic delocalization vs. structural disorder in amorphous silicon
    Herrero, CP
    EUROPHYSICS LETTERS, 1998, 44 (06): : 734 - 740
  • [33] Structural analysis of zwitterionic liquids vs. homologous ionic liquids
    Wu, Boning
    Kuroda, Kosuke
    Takahashi, Kenji
    Castner, Edward W., Jr.
    JOURNAL OF CHEMICAL PHYSICS, 2018, 148 (19):
  • [34] A structural genomics approach to the regulation of apoptosis: Chimp vs. human
    Ahmed, Jessica
    Guenther, Stefan
    Moeller, Friedrich
    Preissner, Robert
    GENOME INFORMATICS 2007, VOL 18, 2007, 18 : 22 - 34
  • [35] Structural vs. cyclic induction - a report on some experiments with Coq
    Stratulat, Sorin
    PROCEEDINGS OF 2016 18TH INTERNATIONAL SYMPOSIUM ON SYMBOLIC AND NUMERIC ALGORITHMS FOR SCIENTIFIC COMPUTING (SYNASC), 2016, : 29 - 36
  • [36] On Material vs. Structural Response of Saturated Granular Soil Specimens
    Manzari, M. T.
    PORO-MECHANICS IV, 2009, : 1033 - 1040
  • [37] Transforming structural econometrics: substantive vs. statistical premises of inference
    Spanos, Aris
    REVIEW OF POLITICAL ECONOMY, 2016, 28 (03) : 426 - 437
  • [38] NOVEL SYNTHETIC DEPSIPEPTIDES: STRUCTURAL FEATURES VS. BIOLOGICAL ACTIVITY
    Chevalley, A.
    Ducrest, P.
    Mayor, S.
    Schnyder, B.
    Mathieu, M.
    JOURNAL OF PEPTIDE SCIENCE, 2016, 22 : S182 - S182
  • [39] Lecture Recording: Structural and Symbolic Information vs. Flexibility of Presentation
    Stolzenberg, Daniel
    Pforte, Stefan
    ELECTRONIC JOURNAL OF E-LEARNING, 2007, 5 (03): : 219 - 226
  • [40] Comments on: "Structural vs. atheoretic approaches to econometrics" by Michael Keane
    Rust, John
    JOURNAL OF ECONOMETRICS, 2010, 156 (01) : 21 - 24