Effect of Desensitizing Agents on the Bond Strength of Mild and Strong Self-etching Adhesives

被引:7
|
作者
Sabatini, C. [1 ]
Wu, Z. [2 ]
机构
[1] SUNY Buffalo, Restorat Dent, Buffalo, NY 14260 USA
[2] Jilin Univ, Sch Stomatol Prosthodont, Changchun 130023, Peoples R China
关键词
DENTINAL HYPERSENSITIVITY; CROSS-LINKING; CLASS-II; COMPOSITE; GLUMA; GLUTARALDEHYDE; SALIVA; WET; SENSITIVITY; INHIBITION;
D O I
10.2341/14-190-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Desensitizing agents are used, almost as routine practice, in many adhesive restorative procedures. There is still debate as to their effect in dentin bonding, particularly with self-etching adhesives. The present study aimed to evaluate the effect of different desensitizing agents on the bond strength of mild and strong self-etching adhesive systems to dentin. Materials and Methods: One hundred twenty recently extracted, noncarious human molars were used to obtain superficial dentin substrate for bonding. No desensitizer was used in the control groups. The experimental groups were pretreated with Gluma Desensitizer, MicroPrime B, and Dentin Desensitizer immediately prior to bonding with self-etching adhesives Optibond XTR, Xeno IV, and iBond. A bonding jig was used to fabricate composite cylinders, which were stored for either 24 hours or three months, after which the shear bond strength (SBS) was evaluated using a notched-edge testing device at a crosshead speed of 1 mm/min. Failure mode distribution was also evaluated at 24 hours and three months. A two-way analysis of variance, Tukey test, and Student t-test, with a significance level of p<0.05, were used for data analysis. Results: At 24 hours, there was no significant difference in SBS when the same adhesive was used with any of the experimental desensitizing agents compared with the control group without desensitizer. However, at three months, Dentin Desensitizer bonded with Optibond XTR demonstrated significantly lower SBS (p<0.001), while Gluma bonded with iBond showed significantly higher SBS values (p=0.034) relative to their corresponding control group. Only MicroPrime B bonded with Xeno IV and iBond with no desensitizer demonstrated a significant reduction in SBS after three months (p=0.034 and p=0.002, respectively). The most prevalent type of failure was adhesive. Conclusion: Desensitizing agents can be used in combination with self-etching adhesives to control hypersensitivity without adversely affecting their bond strength to dentin.
引用
收藏
页码:548 / 557
页数:10
相关论文
共 50 条
  • [31] Bond strength of two self-etching adhesives to enamel with different roughness.
    Sigsworth, P
    Ripps, AH
    Burgess, JO
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A161 - A161
  • [32] Shear bond strength of orthodontic brackets bonded with different self-etching adhesives
    Scougall Vilchis, Rogelio Jose
    Yamamoto, Seigo
    Kitai, Noriyuki
    Yamamoto, Kohji
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (03) : 425 - 430
  • [33] Interfacial Morphology and Bond Strength of Self-Etching Adhesives to Primary Dentin With or Without Acid Etching
    Bolanos-Carmona, Victoria
    Gonzalez-Lopez, Santiago
    De Haro-Munoz, Cristina
    Briones-Lujan, Maria T.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 87B (02) : 499 - 507
  • [34] Effect of blood contamination with 1-step self-etching adhesives on microtensile bond strength to dentin
    Yoo, H. M.
    Pereira, P. N. R.
    OPERATIVE DENTISTRY, 2006, 31 (06) : 660 - 665
  • [35] Effect of smear layer and surface roughness on resin-dentin bond strength of self-etching adhesives
    Saikaew, Pipop
    Senawongse, Pisol
    Chowdhury, A. F. M. Almas
    Sano, Hidehiko
    Harnirattisai, Choltacha
    DENTAL MATERIALS JOURNAL, 2018, 37 (06) : 973 - 980
  • [36] Microtensile bond strength and sealing efficiency of all-in-one self-etching adhesives
    Tekce, Neslihan
    Demirci, Mustafa
    Tuncer, Safa
    Uysal, Omer
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2015, 29 (03) : 570 - 578
  • [37] Ambient humidity vs. bond strength of self-etching adhesives to dentin.
    Finger, WJ
    Tani, C
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 490 - 490
  • [38] Bond strength of composite to astringent-contaminated dentin using self-etching adhesives
    Keefe, KL
    Pinzon, LM
    Rivera, B
    Powers, JM
    AMERICAN JOURNAL OF DENTISTRY, 2005, 18 (03): : 168 - 172
  • [39] Effects of Surface Hydration and Application Method on the Bond Strength of Self-Etching Adhesives to Dentin
    Gomes Torres, Carlos Rocha
    Ferraz Caneppele, Taciana Marco
    Borges, Alessandra Buhler
    Shoji, Aline Vilanova
    Nunes, Talita Macedo
    Batista, Graziela Ribeiro
    JOURNAL OF ADHESION, 2011, 87 (11): : 1099 - 1111
  • [40] Enamel bond strength of two self-etching adhesives at two application times.
    Manuel, N
    Ripps, AH
    Xu, X
    Burgess, JO
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A161 - A161