Computation of load factors in bolted connections

被引:8
|
作者
Cornwell, R. E. [1 ]
机构
[1] Seattle Univ, Dept Mech Engn, Seattle, WA 98122 USA
关键词
bolted joint; load factor; bolted connection; joint stiffness; bolt stiffness; MEMBER STIFFNESS; JOINTS;
D O I
10.1243/09544062JMES1108
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
An accurate computation of the joint load factors is critical for the safe design of bolted connections. This study provides a four-step procedure for the direct computation of the joint load factors for a variety of bolt diameters, joint thicknesses, individual plate thicknesses, and plate material combinations. The finite element method was used to calculate the bolt and plate deformations necessary to directly compute the load factor for 4424 unique combinations of the four joint design parameters. The procedure developed in this study provides accurate estimates of the joint load factor over the entire range of the four joint design parameters. All 4424 joint designs originally analysed with the finite element method were recomputed using the proposed procedure. The root mean square error was found to be 0.58 per cent with a correlation coefficient between the load factors computed by using the original finite element analyses and the proposed procedure to be 0.9998.
引用
收藏
页码:795 / 808
页数:14
相关论文
共 50 条
  • [21] THE TIGHTENING AND LOOSENING OF BOLTED CONNECTIONS
    MITSUNAGA, K
    JOURNAL OF JAPAN SOCIETY OF LUBRICATION ENGINEERS, 1986, 31 (03): : 163 - 166
  • [22] RELIABILITY OF BOLTED WOOD CONNECTIONS
    ZAHN, JJ
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (12): : 3362 - 3376
  • [23] Numerical simulation of bolted connections
    Leite Vilela, Paula Moura
    Carvalho, Hermes
    Baiao Filho, Oswaldo Teixeira
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2018, 15 (10):
  • [24] Bolted endplate connections revisited
    Olsen, PC
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2002, 58 (09) : 1265 - 1280
  • [25] Design of bolted endplate connections
    Olsen, PC
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1997, 43 (1-3) : 119 - 140
  • [26] Committee on bolted flanged connections
    Welding Research Council, Progress Reports, 1994, 49 (1-2):
  • [27] Assessment of Resistance Factors for LRFD of Steel Bolted Connections in Pultruded FRP Frames
    Pirchio, David
    Althouse, Jake A.
    Madlem, Troy A.
    Denavit, Mark D.
    De Caso y Basalo, Francisco J.
    Busel, John P.
    Kurama, Yahya C.
    Walsh, Kevin Q.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2024, 28 (02)
  • [28] Influence of strain-hardening on the load-carrying behaviour of bearing type bolted connections
    Studer, Patrick
    Taras, Andreas
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 191
  • [29] Approximations in Alternate Load Path Capacity of Welded Unreinforced Flange-Bolted Web Connections
    Rezvani, Farshad Hashemi
    Ronagh, Hamid R.
    STRUCTURES CONGRESS 2018: BUILDINGS AND DISASTER MANAGEMENT, 2019, : 11 - 20
  • [30] Fretting fatigue and wear in bolted connections: A multi-level formulation for the computation of local contact stresses
    Zografos, Angelos
    Dini, Daniele
    Olver, Andrew V.
    TRIBOLOGY INTERNATIONAL, 2009, 42 (11-12) : 1663 - 1675