Steep freeform measurement method based on a normal transverse differential confocal

被引:5
|
作者
Wang, Wenbin [1 ]
Zheng, Xin [1 ]
Liu, Yuhan [1 ]
Li, Menghan [1 ]
Zhang, Xiaocheng [1 ]
Qiu, Lirong [1 ]
Zhao, Weiqian [1 ]
机构
[1] Beijing Inst Technol, Sch Opt & Photon, Beijing 100081, Peoples R China
关键词
SURFACE;
D O I
10.1364/OE.474700
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A normal transverse laser differential confocal freeform measurement (NTDCFM) method was proposed to address the high-precision measurement difficulty of steep freeform surfaces with large variations in inclination, scattering, and reflectance. Using D-shaped diaphragm technology, the freeform surface under test (FSUT) axial variation transformed into a spot transverse movement on the detection focal plane. Meanwhile, a 2D position sensitive detector (PSD) was used to obtain the normal vector of the sampling points so that the measuring sensor's optical axis could track the FSUT normal direction. The focus tracking method extended the sensor measurement range. Theoretical analysis and experimental results showed that the axial resolution of the NTDCFM was better than 0.5 nm, the direction resolution of the normal vector was 0.1 degrees, the maximum surface inclination could be measured up to 90 degrees, the sensor range was 5 mm, and the measurement repeatability of the FSUT was better than 9 nm. It provides an effective new anti-inclination, anti-scattering, and anti-reflectivity method for accurately measuring steep freeform surfaces. (c) 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:41804 / 41820
页数:17
相关论文
共 50 条
  • [41] Analysis and Research on Spectral Confocal Displacement Measurement Method Based on GRNN
    Li Chunyan
    Li Gengpeng
    Liu Jihong
    Luo Dou
    Liu Jiayi
    ACTA PHOTONICA SINICA, 2022, 51 (03)
  • [42] Research on micro displacement measurement technology based on chromatic confocal method
    Qi Yuejing
    Lu Zengxiong
    Ma Jing
    Yang Guanghua
    Zhang Qingyang
    Li Bing
    Qi Wei
    Su Jiani
    9TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES (AOMATT 2018): MICRO- AND NANO-OPTICS, CATENARY OPTICS, AND SUBWAVELENGTH ELECTROMAGNETICS, 2019, 10840
  • [43] Nano-displacement measurement based on virtual pinhole confocal method
    Li, Long
    Kuang, Cuifang
    Xue, Yi
    Liu, Xu
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (03)
  • [44] Contactless Method for Measurement of Surface Roughness Based on a Chromatic Confocal Sensor
    Lishchenko, Natalia
    O'Donnell, Garret E.
    Culleton, Mark
    MACHINES, 2023, 11 (08)
  • [45] Calculation of the Normal Vector using the 3 × 3 Moving Mask Method for Freeform Surface Measurement and its Application
    F.-J. Shiou
    Y.-F. Lin
    The International Journal of Advanced Manufacturing Technology, 2002, 19 : 516 - 524
  • [46] Laser differential confocal lens refractive index measurement
    Zhao, Weiqian
    Wang, Yun
    Qiu, Lirong
    Guo, Haorong
    APPLIED OPTICS, 2011, 50 (24) : 4769 - 4778
  • [47] Development of laser differential confocal radius measurement system
    Sun, Ruoduan
    Qiu, Lirong
    Yang, Jiamiao
    Zhao, Weiqian
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2011, 32 (12): : 2833 - 2838
  • [48] Differential confocal measurement for surface topography with microstructures based on spiral scanning and wavelet filter
    Wang, Jiale
    Cui, Yuguo
    Liang, Dan
    Wang, Yiqiang
    Ying, Ronghui
    APPLIED OPTICS, 2020, 59 (36) : 11359 - 11370
  • [49] Laser differential confocal paraboloidal vertex radius measurement
    Yang, Jiamiao
    Qiu, Lirong
    Zhao, Weiqian
    Shen, Yang
    Jiang, Hongwei
    OPTICS LETTERS, 2014, 39 (04) : 830 - 833
  • [50] Transverse vibration of an axially moving plate based on differential quadrature method
    Liu, Jin-Tang
    Yang, Xiao-Dong
    Wen, Bang-Chun
    Zhendong yu Chongji/Journal of Vibration and Shock, 2009, 28 (03): : 178 - 181