Modelling the response function of energy dispersive X-ray spectrometers with silicon detectors

被引:109
|
作者
Scholze, F. [1 ]
Procop, M. [2 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
[2] Bundesanstalt Mat Forsch & Prufung, D-12200 Berlin, Germany
关键词
ELECTRON-HOLE PAIR; SI(LI) DETECTOR; RANGE; CALIBRATION; SPECTRA; PHOTOIONIZATION; TRANSMISSION; PARAMETERS; SCATTERING; EFFICIENCY;
D O I
10.1002/xrs.1165
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A new, analytical description of the physical processes determining the spectral response of an energy dispersive X-ray spectrometer with a silicon detector (Si(Li) or silicon drift detector (SDD)) is presented. The model considers the detector statistical noise, the electronic noise, the incomplete charge collection (ICC) that gives rise to the peak tailing, the escape effect, the fluorescence of the front contact or the dead layer and hot photoelectrons that cause the shelf. Only five free parameters are necessary to model the response function: the electronic noise, three parameters describing the shape of the charge collection efficiency beneath the front contact and the thickness of the detector front layer. Once the five parameters are adjusted to have agreement between a measured and a calculated response function, the response function can be calculated for any other photon energy in the range from 0.1 keV to 30 keV. The algorithm is implemented in IDL and MATLAB and is available also as MATLAB stand-alone program. It enables the determination of the optimum parameter set by fitting a calculated response function to a measured one for monochromatic radiation. A (m,n)-type matrix can be calculated whereby m represents the number of channels for the response function and n the number of photon energies in the selected range. The matrix can be used to convolute a calculated spectrum for comparison with a measured one. The calculated response functions are in agreement with the pulse height distributions measured with monochromatic synchrotron radiation in the energy range from 0.1 keV to 10 keV for three spectrometers with detector crystals different in construction. It is shown that the improved description of the detector response enables the detection of minor components of characteristic lines in fluorescence spectra, which have been attributed earlier to the detector. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:312 / 321
页数:10
相关论文
共 50 条
  • [41] X-RAY-DETECTORS AND SPECTROMETERS
    LYMAN, CE
    WILLIAMS, DB
    GOLDSTEIN, JI
    ULTRAMICROSCOPY, 1989, 28 (1-4) : 137 - 149
  • [42] USE OF SENSITIVITY AS A FUNCTION OF FLUORESCENT X-RAY-ENERGY IN ENERGY-DISPERSIVE X-RAY SPECTROMETRY
    WEGSCHEIDER, W
    ELLIS, AT
    GOLDBACH, K
    LEYDEN, DE
    MAHAN, KI
    ANALYTICA CHIMICA ACTA, 1986, 188 : 59 - 66
  • [43] Calibration of energy-dispersive X-ray detectors at BESSY I and BESSY II
    Scholze, F
    Thornagel, R
    Ulm, G
    METROLOGIA, 2001, 38 (05) : 391 - 395
  • [44] Modelling an Energy-Dispersive X-Ray Diffraction System for Drug Detection
    Pani, Silvia
    Cook, Emily
    Horrocks, Julie
    George, Leah
    Hardwick, Sheila
    Speller, Robert
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 1238 - 1241
  • [45] Computational modelling of semiconducting X-ray detectors
    Fowler, RF
    Ashby, JV
    Greenough, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 226 - 231
  • [46] LOW-ENERGY RESPONSE OF SUPERCONDUCTING TUNNEL JUNCTION X-RAY SPECTROMETERS
    LABOV, SE
    HILLER, LH
    MEARS, CA
    FRANK, M
    NETEL, H
    AZGUI, F
    BARFKNECHT, AT
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1995, 5 (02) : 3034 - 3037
  • [47] Structural study of molten silicon by energy dispersive x-ray diffraction method
    Takeda, Susumu
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes & Review Papers, 1995, 34 (9 A): : 4889 - 4893
  • [48] Advances in silicon carbide X-ray detectors
    Bertuccio, Giuseppe
    Caccia, Stefano
    Puglisi, Donatella
    Macera, Daniele
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 193 - 196
  • [49] INTERNAL STRAIN OF SILICON STUDIED BY X-RAY ENERGY-DISPERSIVE DIFFRACTION
    COUSINS, CSG
    GERWARD, L
    OLSEN, JS
    SELSMARK, B
    SHELDON, BJ
    PHYSICA SCRIPTA, 1982, 25 (06): : 871 - 872
  • [50] High efficiency silicon X-ray detectors
    Tull, CR
    Iwanczyk, JS
    Patt, BE
    Barkan, S
    Feng, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1803 - 1807