Shear-Wave Elastography: Basic Physics and Musculoskeletal Applications
被引:469
|
作者:
Taljanovic, Mihra S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Arizona, Coll Med, Dept Med Imaging, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USAUniv Arizona, Coll Med, Dept Med Imaging, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USA
Taljanovic, Mihra S.
[1
]
Gimber, Lana H.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Arizona, Coll Med, Dept Med Imaging, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USAUniv Arizona, Coll Med, Dept Med Imaging, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USA
Gimber, Lana H.
[1
]
Becker, Giles W.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Arizona, Coll Med, Dept Orthopaed Surg, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USAUniv Arizona, Coll Med, Dept Med Imaging, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USA
Becker, Giles W.
[2
]
论文数: 引用数:
h-index:
机构:
Latt, L. Daniel
[2
]
论文数: 引用数:
h-index:
机构:
Klauser, Andrea S.
[3
]
Melville, David M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Arizona, Coll Med, Dept Med Imaging, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USAUniv Arizona, Coll Med, Dept Med Imaging, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USA
Melville, David M.
[1
]
Gao, Liang
论文数: 0引用数: 0
h-index: 0
机构:
Univ Arizona, Coll Opt Sci, Tucson, AZ USAUniv Arizona, Coll Med, Dept Med Imaging, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USA
Gao, Liang
[4
]
Witte, Russell S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Arizona, Coll Med, Dept Med Imaging, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USAUniv Arizona, Coll Med, Dept Med Imaging, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USA
Witte, Russell S.
[1
]
机构:
[1] Univ Arizona, Coll Med, Dept Med Imaging, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USA
[2] Univ Arizona, Coll Med, Dept Orthopaed Surg, 1501 N Campbell Ave,POB 245067, Tucson, AZ 85724 USA
[3] Med Univ Innsbruck, Dept Radiol, Sect Rheumatol & Sports Imaging, Innsbruck, Austria
In the past 2 decades, sonoelastography has been progressively used as a tool to help evaluate soft-tissue elasticity and add to information obtained with conventional gray-scale and Doppler ultrasonographic techniques. Recently introduced on clinical scanners, shear-wave elastography (SWE) is considered to be more objective, quantitative, and reproducible than compression sonoelastography with increasing applications to the musculoskeletal system. SWE uses an acoustic radiation force pulse sequence to generate shear waves, which propagate perpendicular to the ultrasound beam, causing transient displacements. The distribution of shear-wave velocities at each pixel is directly related to the shear modulus, an absolute measure of the tissue's elastic properties. Shear-wave images are automatically coregistered with standard B-mode images to provide quantitative color elastograms with anatomic specificity. Shear waves propagate faster through stiffer contracted tissue, as well as along the long axis of tendon and muscle. SWE has a promising role in determining the severity of disease and treatment follow-up of various musculoskeletal tissues including tendons, muscles, nerves, and ligaments. This article describes the basic ultrasound physics of SWE and its applications in the evaluation of various traumatic and pathologic conditions of the musculoskeletal system. (C) RSNA, 2017
机构:
Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
Henry Ford Hlth Syst, Dept Radiol, 2799 West Grand Blvd, Detroit, MI 48202 USAMed Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
Davis, Leah C.
Baumer, Timothy G.
论文数: 0引用数: 0
h-index: 0
机构:
Henry Ford Hlth Syst, Bone & Joint Ctr, Dept Orthopaed Surg, Detroit, MI USAMed Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
Baumer, Timothy G.
Bey, Michael J.
论文数: 0引用数: 0
h-index: 0
机构:
Henry Ford Hlth Syst, Bone & Joint Ctr, Dept Orthopaed Surg, Detroit, MI USAMed Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
Bey, Michael J.
van Holsbeeck, Marnix
论文数: 0引用数: 0
h-index: 0
机构:
Henry Ford Hlth Syst, Dept Radiol, 2799 West Grand Blvd, Detroit, MI 48202 USAMed Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA