Large volume sample stacking for rapid and sensitive determination of antidiabetic drug metformin in human urine and serum by capillary electrophoresis with contactless conductivity detection

被引:37
|
作者
Tuma, Petr [1 ]
机构
[1] Charles Univ Prague, Fac Med 3, Inst Biochem Cell & Mol Biol, Ruska 87, Prague 10000 10, Czech Republic
关键词
Antidiabetic drug; Capillary electrophoresis; Contact less conductivity detection; Large volume sample stacking; Rapid separation; PERIAQUEDUCTAL GRAY-MATTER; TYPE-2; DIABETES-MELLITUS; TANDEM MASS-SPECTROMETRY; ZONE-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; PHARMACEUTICAL-PREPARATIONS; DOSAGE FORMULATIONS; HUMAN PLASMA; AMINO-ACIDS; VALIDATION;
D O I
10.1016/j.chroma.2014.04.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two CE methods with contactless conductivity detection have been developed for determining the oral antidiabetic drug metformin in human urine and blood. The determination of metformin is performed on a separation capillary with an effective length of 14 cm, using a maximum voltage of 30 kV and with a small injection of 50-fold diluted urine into the capillary. Under these conditions, the migration time of metformin is 35 s and the LOD is 0.3 mu M Large-volume sample stacking was used to determine low metformin levels in serum. The injection of a sample of serum deproteinized with acetonitrile was 10 times greater compared to the injected amount of urine. This enabled reduction of the LOD to 0.03 mu M and the metformin migration time equalled 86 s. The undesirable solvent from sample zone was forced out of the capillary to ensure rapidity and good repeatability of the determination. The RSD values for the migration time are 0.1% for urine and 0.7% for serum; RSD for the peak areas equalled 1.4% for urine and 2.6% for serum. The developed CE technique was tested on performance of routine analyses of metformin in the urine and serum of patients suffering from type II diabetes mellitus. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:207 / 211
页数:5
相关论文
共 50 条
  • [21] Large-volume sample stacking for in vivo monitoring of trace levels of γ-aminobutyric acid, glycine and glutamate in microdialysates of periaqueductal gray matter by capillary electrophoresis with contactless conductivity detection
    Tuma, Petr
    Sustkova-Fiserova, Magdalena
    Opekar, Frantisek
    Pavlicek, Vaclav
    Malkova, Klara
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1303 : 94 - 99
  • [22] Rapid and sensitive determination of posaconazole in patient plasma by capillary electrophoresis with field-amplified sample stacking
    Liao, Hsiao-Wei
    Lin, Shu-Wen
    Wu, Un-In
    Kuo, Ching-Hua
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1226 : 48 - 54
  • [23] Efficient sample clean-up and online preconcentration for sensitive determination of melamine in milk samples by capillary electrophoresis with contactless conductivity detection
    Ji, Yan-ling
    Chen, Xiao-wei
    Zhang, Zhu-bao
    Li, Jing
    Xie, Tian-yao
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (20) : 3000 - 3006
  • [24] Rapid determination of neurotransmitters in human urine using capillary electrophoresis with UV detection
    Gehrke, Sarah A.
    Culhane, Kyle M.
    Shin, Mimi
    Robinson, Randy J.
    Liu, Pengxin
    Weiss, David J.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242
  • [25] Determination of tamoxifen and its metabolites in human plasma by nonaqueous capillary electrophoresis with contactless conductivity detection
    Thang, Lee Yien
    Shahir, Shafinaz
    See, Hong Heng
    ELECTROPHORESIS, 2015, 36 (21) : 2713 - 2719
  • [26] Rapid determination of partition coefficients of pharmaceuticals by phase distribution and microchip capillary electrophoresis with contactless conductivity detection
    Wang, Sifeng
    Chen, Zuanguang
    Tang, Xiuwen
    Shi, Lijuan
    Zhang, Lin
    Yao, Meicun
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (21-22) : 3615 - 3622
  • [27] Determination of free and total valproic acid in human plasma by capillary electrophoresis with contactless conductivity detection
    Thi Thanh Thuy Pham
    See, Hong Heng
    Morand, Rejane
    Kraehenbuehl, Stephan
    Hauser, Peter C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 907 : 74 - 78
  • [28] Determination of uric acid in human urine and serum by capillary electrophoresis with chemiluminescence detection
    Zhao, Shulin
    Wang, Jianshi
    Ye, Fanggui
    Liu, Yi-Ming
    ANALYTICAL BIOCHEMISTRY, 2008, 378 (02) : 127 - 131
  • [29] Determination of a basic drug, bambuterol, in human plasma by capillary electrophoresis using double stacking for large volume injection and supported liquid membranes for sample pretreatment
    Palmarsdottir, S
    Mathiasson, L
    Jonsson, JA
    Edholm, LE
    JOURNAL OF CHROMATOGRAPHY B, 1997, 688 (01): : 127 - 134
  • [30] Determination of imatinib mesylate and related compounds by field amplified sample stacking with large volume sample injection capillary electrophoresis
    Li, Jian
    Huang, Yifei
    Huang, Lei
    Ye, Lei
    Zhou, Zhou
    Xiang, Guangya
    Xu, Li
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 : 26 - 31