Tuning properties of the auditory frequency-shift detectors

被引:31
|
作者
Demany, Laurent [1 ]
Pressnitzer, Daniel [2 ,3 ]
Semal, Catherine [1 ]
机构
[1] Univ Bordeaux, Lab Mouvement, UMR CNRS 5227, F-33076 Bordeaux, France
[2] Univ Paris 05, Dept Etud Cognit, Lab Psychol Percept, UMR CNRS 8158, F-75230 Paris 05, France
[3] Ecole Normale Super, F-75230 Paris 05, France
来源
关键词
PERCEPTUAL ORGANIZATION; CORTEX; REPRESENTATION; CONSTRAINTS; MOTION;
D O I
10.1121/1.3179675
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Demany and Ramos [(2005). J. Acoust. Soc. Am. 117, 833-841] found that it is possible to hear an upward or downward pitch change between two successive pure tones differing in frequency even when the first tone is informationally masked by other tones, preventing a conscious perception of its pitch. This provides evidence for the existence of automatic frequency-shift detectors (FSDs) in. the auditory system. The present study was intended to estimate the magnitude of the frequency shifts optimally detected by the FSDs. Listeners were presented with sound sequences consisting of (1) a 300-ms or 100-ms random "chord" of synchronous pure tones, separated by constant intervals of either 650 cents or 1000 cents; (2) an interstimulus interval (ISI) varying from 100 to 900 ms; (3) a single pure tone at a variable frequency distance (Delta) from a randomly selected component of the chord. The task was to indicate if the final pure tone was higher or lower than the nearest component of the chord. Irrespective of the chord's properties and of the ISI, performance was best when Delta was equal to about 120 cents (1/10 octave). Therefore, this interval seems to be the frequency shift optimally detected by the FSDs. (c) 2009 Acoustical Society of America. [DOI: 10.1121/1.3179675]
引用
收藏
页码:1342 / 1348
页数:7
相关论文
共 50 条
  • [41] ON CERTAIN ASPECTS OF THE RELATIVISTIC FREQUENCY-SHIFT FORMULA
    BAZANSKI, SL
    NUKLEONIKA, 1980, 25 (11-1) : 1393 - 1404
  • [42] Frequency-Shift Offset-QAM for GFDM
    Gaspar, Ivan
    Matthe, Maximilian
    Michailow, Nicola
    Mendes, Luciano Leonel
    Zhang, Dan
    Fettweis, Gerhard
    IEEE COMMUNICATIONS LETTERS, 2015, 19 (08) : 1454 - 1457
  • [43] FREQUENCY-SHIFT IN 3-PHOTON RESONANCE
    FRIEDBERG, R
    HARTMANN, SR
    MANASSAH, JT
    PHYSICAL REVIEW A, 1989, 39 (01): : 93 - 94
  • [44] PLASMON LINEWIDTH AND FREQUENCY-SHIFT IN DENSE MATTER
    ITOH, N
    KOHYAMA, Y
    ICHIMARU, S
    UTSUMI, K
    HASEGAWA, M
    PHYSICAL REVIEW LETTERS, 1982, 49 (26) : 1932 - 1935
  • [45] FREQUENCY-SHIFT MODULATOR AND MIXER COMPATIBILITY ANALYSIS
    PERVUKHINA, GP
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1986, 29 (11): : 61 - 64
  • [46] GENERALIZED FREQUENCY-SHIFT ASSOCIATED WITH TACHYONS AND ANTIPARTICLES
    LAKE, K
    ROEDER, RC
    LETTERE AL NUOVO CIMENTO, 1975, 12 (16): : 641 - 644
  • [47] MEASURING OF FREQUENCY-SHIFT IN AN ACCELERATED LINEAR LASER
    GOLUBKOV, VS
    EVTIKHIE.NN
    PAPULOVS.VF
    RADIOTEKHNIKA I ELEKTRONIKA, 1974, 19 (06): : 1312 - 1313
  • [48] FREQUENCY-SHIFT AND CAVITY LENGTH IN PHOTOREFRACTIVE RESONATORS
    EWBANK, MD
    YEH, P
    OPTICS LETTERS, 1985, 10 (10) : 496 - 498
  • [49] FREQUENCY-SHIFT OF SELF-TRAPPED LIGHT
    LANGDON, AB
    LASINSKI, BF
    PHYSICS OF FLUIDS, 1983, 26 (02) : 582 - 587
  • [50] DYNAMIC NMR FREQUENCY-SHIFT IN THE INVERTED STATE
    TSIFRINOVICH, VI
    ZHURNAL EKSPERIMENTALNOI I TEORETICHESKOI FIZIKI, 1982, 83 (02): : 715 - 717