Analysis of the passive heat removal enhancement for AP1000 containment due to the partially wetted coverage

被引:2
|
作者
Li, Cheng [1 ]
Li, Le [2 ]
Li, Junming [3 ]
Zhang, Yajun [2 ]
Li, Zhihui [1 ]
机构
[1] State Nucl Power Technol Res & Dev Ctr, Beijing 102209, Peoples R China
[2] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Key Lab Thermal Sci & Power Engn, Minist Educ, Dept Thermal Engn, Beijing 100084, Peoples R China
关键词
Shell thermal conduction; AP1000; containment; Wetted coverage; Condensation and evaporation; CONDENSATION; EVAPORATION;
D O I
10.1016/j.nucengdes.2016.12.022
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
AP1000 containment uses the water film evaporation, coupled with containment inner condensation, to remove the core decay heat. However, water film cannot fully cover heat transfer surface and dry-wetted strips appear. As a result, heat transfer within the containment shell is a two-dimension thermal conduction. Current work numerically studied the AP1000 heat removal enhancement due to the partially wetted coverage phenomenon. It used the evaporation and condensation boundary conditions and Fluent software to calculate the local heat fluxes and their distributions. Results show that the maximum heat transfer enhancement can reach 63% and this enhancement peak appears when the dry strip fraction approximately equals 90%. The influences of dry coverage and dry-wet strip width were carefully discussed. It indicates that the heat transfer enhancement for small dry-wet strip is linear with dry strip fraction (0 < alpha < 80%). Finally, according to the wetted coverage ranges for AP1000 passive containment cooling system, an empirical correlation for heat transfer enhancement is given and it can be used to improve PCCS analysis. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:185 / 189
页数:5
相关论文
共 50 条
  • [21] NUMERICAL RESEARCH ON PERFORMANCE OF AP1000 PASSIVE CONTAINMENT COOLING SYSTEM WITHOUT FALLING FILM
    Wang Hui
    Guo Qiang
    Chen Qiaoyan
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 3, 2014,
  • [22] ANALYSIS OF THE THERMAL HYDRAULIC PHENOMENA CAUSED BY STEAM JETS IN AP1000 CONTAINMENT
    Hu, Yingqiu
    Yu, Yu
    Niu, Fenglei
    Liu, Xin
    Zhao, Ruichang
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 3, 2014,
  • [23] AP1000® PASSIVE COOLING CONTAINMENT ANALYSIS OF A DOUBLE-ENDED LBLOCA WITH A 3D GOTHIC MODEL
    Estevez-Albuja, Samanta
    Jimenez, Gonzalo
    Fernandez-Cosials, Kevin
    Queral, Cesar
    Goni, Zurine
    PROCEEDINGS OF THE 26TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2018, VOL 6B, 2018,
  • [24] Comparative study on aerosol removal by natural processes in containment in severe accident for AP1000 reactor
    Sun, Xiaohui
    Cao, Xinrong
    Shi, Xingwei
    Yan, Jin
    ANNALS OF NUCLEAR ENERGY, 2017, 99 : 216 - 226
  • [25] AP1000 Passive Containment Cooling System study under LBLOCA conditions using the GOTHIC code
    Estevez-Albuja, Samanta
    Fernandez-Cosials, Kevin
    Vazquez-Rodriguez, Carlos
    Goni-Velilla, Zurin
    Jimenez, Gonzalo
    NUCLEAR ENGINEERING AND DESIGN, 2021, 384
  • [26] Invariant methods for an ensemble-based sensitivity analysis of a passive containment cooling system of an AP1000 nuclear power plant
    Di Maio, Francesco
    Nicola, Giancarlo
    Borgonovo, Emanuele
    Zio, Enrico
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2016, 151 : 12 - 19
  • [27] Dynamic response analysis of a large commercial aircraft hitting the AP1000 containment vessel
    Wang D.
    Wang X.
    Yang Q.
    Zhang Y.
    Wu C.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2022, 41 (10): : 260 - 269and291
  • [28] ANALYSIS OF LIQUID SLOSHING IN AN IN-CONTAINMENT REFUELING WATER STORAGE TANK FOR AP1000
    Liu, Yu
    Lu, Daogang
    Dang, Junjie
    Wu, Licun
    Ma, Wenhui
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 3, 2014,
  • [29] Prediction of falling film evaporation on the AP1000 paSsive containment cooling system using ANSYS FLUENT code
    Wang, Xianmao
    Chang, Huajian
    Corradini, Michael
    Cong, Tenglong
    Wang, Jun
    ANNALS OF NUCLEAR ENERGY, 2016, 95 : 168 - 175
  • [30] Experimental study of primary and secondary side coupling natural convection heat transfer characteristics of the passive residual heat removal system in AP1000
    Zhimin QIU
    Daogang LU
    Jingpin FU
    Li FENG
    Yuhao ZHANG
    Frontiers in Energy, 2021, (04) : 860 - 871