Analysis of the passive heat removal enhancement for AP1000 containment due to the partially wetted coverage

被引:2
|
作者
Li, Cheng [1 ]
Li, Le [2 ]
Li, Junming [3 ]
Zhang, Yajun [2 ]
Li, Zhihui [1 ]
机构
[1] State Nucl Power Technol Res & Dev Ctr, Beijing 102209, Peoples R China
[2] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Key Lab Thermal Sci & Power Engn, Minist Educ, Dept Thermal Engn, Beijing 100084, Peoples R China
关键词
Shell thermal conduction; AP1000; containment; Wetted coverage; Condensation and evaporation; CONDENSATION; EVAPORATION;
D O I
10.1016/j.nucengdes.2016.12.022
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
AP1000 containment uses the water film evaporation, coupled with containment inner condensation, to remove the core decay heat. However, water film cannot fully cover heat transfer surface and dry-wetted strips appear. As a result, heat transfer within the containment shell is a two-dimension thermal conduction. Current work numerically studied the AP1000 heat removal enhancement due to the partially wetted coverage phenomenon. It used the evaporation and condensation boundary conditions and Fluent software to calculate the local heat fluxes and their distributions. Results show that the maximum heat transfer enhancement can reach 63% and this enhancement peak appears when the dry strip fraction approximately equals 90%. The influences of dry coverage and dry-wet strip width were carefully discussed. It indicates that the heat transfer enhancement for small dry-wet strip is linear with dry strip fraction (0 < alpha < 80%). Finally, according to the wetted coverage ranges for AP1000 passive containment cooling system, an empirical correlation for heat transfer enhancement is given and it can be used to improve PCCS analysis. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:185 / 189
页数:5
相关论文
共 50 条
  • [1] Analysis of passive residual heat removal system in AP1000 nuclear power plant
    Sierchula, J.
    INTERNATIONAL CONFERENCE ON THE SUSTAINABLE ENERGY AND ENVIRONMENTAL DEVELOPMENT, 2019, 214
  • [2] Optimal structural analysis with associated passive heat removal for AP1000 shield building
    Lee, Duen-Sheng
    Liu, Ming-Lou
    Hung, Tzu-Chen
    Tsai, Chung-Han
    Chen, Yi-Tung
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 207 - 216
  • [3] ANALYSIS OF HEAT TRANSFER AND FLOW CHARACTERISTICS OF AP1000 PASSIVE RESIDUAL HEAT REMOVAL HEAT EXCHANGER
    Xie, Xu
    Nie, Changhua
    Zhan, Li
    Zheng, Hua
    Li, Pengzhou
    Tian, Wenxi
    Yu, Pei
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 2B, 2014,
  • [4] Reliability Analysis on Passive Residual Heat Removal of AP1000 Based on Grey Model
    Shi, Qi
    Tao, Zhou
    Shahzad, Muhammad Ali
    Yu, Li
    Jiang Guangming
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2017, 62 (06): : 408 - +
  • [5] AP1000® Passive Cooling Containment Analysis With Computational Fluid Dynamics Codes
    Jimenez, Gonzalo
    Goni, Zurine
    del Rio, Gonzalo
    Estevez, Samanta
    Queral, Cesar
    26TH INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE (NENE 2017), 2017,
  • [6] THERMAL - HYDRAULIC PERFORMANCE ANALYSIS FOR AP1000 PASSIVE CONTAINMENT COOLING SYSTEM
    Yu, Yu
    Wang, Shengfei
    Niu, Fenglei
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 4, 2014,
  • [7] Design and optimization of AP1000 passive residual heat removal system based on fault tree analysis
    Qian, Xiao-Ming
    Lu, Dao-Gang
    Yu, Yu
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2012, 46 (08): : 927 - 930
  • [8] Analysis on pressure response of containment subcompartments for AP1000
    Cai, Wei
    Chen, Wen-Hu
    Xu, Liang-Wang
    Zhang, Ying
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2013, 47 (12): : 2267 - 2271
  • [9] Heat removal analysis in the AP1000 reactor's refuelling process
    Isnaini, Muh Darwis
    Subekti, M.
    SYMPOSIUM OF EMERGING NUCLEAR TECHNOLOGY AND ENGINEERING NOVELTY (SENTEN 2018), 2019, 1198
  • [10] Analysis of AP1000 containment passive cooling system during a loss-of-coolant accident
    Hung, Zhen-Yu
    Ferng, Yuh-Ming
    Hsu, Wen-Sheng
    Pei, Bau-Shei
    Chen, Yen-Shu