High-performance liquid chromatographic method for simple and rapid determination of linezolid in human plasma

被引:48
|
作者
Boak, Lauren M. [1 ]
Li, Jian [1 ]
Nation, Roger L. [1 ]
Rayner, Craig R. [1 ]
机构
[1] Monash Univ, Facil Antiinfect Drug Dev & Innovat, Dept Pharm Practice, Victorian Coll Pharm, Parkville, Vic 3052, Australia
关键词
linezolid; HPLC; plasma;
D O I
10.1002/bmc.597
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple high-performance liquid chromatographic (HPLC) method was developed and validated for rapid quantification of linezolid in human plasma. Protein precipitation using a mixture of 5% trichloroacetic acid and methanol (3:1, v/v) provided a straightforward method of sample preparation and the internal standard eperezolid was employed. A concentration range from 0.20 to 40.0 mg/L was utilized to construct calibration curves, and analysis of low- (0.40 mg/L), medium- (7.50 mg/L) and high-quality (25.0 mg/L) control samples revealed excellent reproducibility (<= 3.88%) and accuracy (<= 4.20%). The recovery of both linezolid and eperezolid was approximately 100%. No interference was observed at the retention times of linezolid and eperezolid from blank plasma or eight commonly used antibiotics. Tests confirmed the stability of linezolid in plasma during three freeze-thaw cycles, on the bench during 24 h and during long-term storage of frozen plasma for up to 12 weeks; in extracts it was stable in the HPLC autosampler over 12 h. Overall, this assay offers a highly simplistic approach to quantifying linezolid in plasma, and would be well suited to clinical pharmacokinetic, pharmacodynamic and toxicodynamic analyses. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:782 / 786
页数:5
相关论文
共 50 条
  • [1] Simple and rapid high-performance liquid chromatographic method for endogenous α-tocopherol determination in human plasma
    Nirungsan, Katthaleeya
    Thongnopnua, Phensri
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (08) : 774 - 781
  • [2] Rapid and simple high-performance liquid chromatographic determination of nimesulide in human plasma
    Ptácek, P
    Macek, J
    Klíma, J
    JOURNAL OF CHROMATOGRAPHY B, 2001, 758 (02): : 183 - 188
  • [3] Rapid simple high-performance liquid chromatographic determination of paroxetine in human plasma
    Shin, JG
    Kim, KA
    Yoon, YR
    Cha, IJ
    Kim, YH
    Shin, SG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 713 (02): : 452 - 456
  • [4] Rapid simple high-performance liquid chromatographic determination of paroxetine in human plasma
    Shin, Jae-Gook
    Kim, Kyung-Ah
    Yoon, Young-Ran
    Chan, In-June
    Kim, Young-Hoon
    Shin, Sang-Goo
    Journal of Chromatography B, 1998, 713 (02): : 452 - 456
  • [5] Simple high-performance liquid chromatographic method for determination of α-tocopherol in human plasma
    Julianto, T
    Yuen, KH
    Noor, AM
    JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (01): : 227 - 231
  • [6] Simple high-performance liquid chromatographic method for the determination of ranitidine in human plasma
    Wong, CF
    Peh, KK
    Yuen, KH
    JOURNAL OF CHROMATOGRAPHY B, 1998, 718 (01): : 205 - 210
  • [8] Simple high-performance liquid chromatographic method for the determination of tocotrienols in human plasma
    Yap, SP
    Julianto, T
    Wong, JW
    Yuen, KH
    JOURNAL OF CHROMATOGRAPHY B, 1999, 735 (02): : 279 - 283
  • [9] Simple high-performance liquid chromatographic method for the determination of metformin in human plasma
    Yuen, KH
    Peh, KK
    JOURNAL OF CHROMATOGRAPHY B, 1998, 710 (1-2): : 243 - 246
  • [10] Simple high-performance liquid chromatographic method for determination of ketoconazole in human plasma
    Yuen, KH
    Peh, KK
    JOURNAL OF CHROMATOGRAPHY B, 1998, 715 (02): : 436 - 440