Assessment of a new point-of-care system for detection of prostate specific antigen

被引:4
|
作者
Rausch, Steffen [1 ]
Hennenlotter, Joerg [1 ]
Wiesenreiter, Josef [1 ]
Hohneder, Andrea [1 ]
Heinkele, Julian [1 ]
Schwentner, Christian [1 ]
Stenzl, Arnulf [1 ]
Todenhofer, Tilman [1 ,2 ]
机构
[1] Univ Tubingen, Dept Urol, D-72076 Tubingen, Germany
[2] Univ British Columbia, Vancouver Prostate Ctr, Vancouver, BC V6H 3Z6, Canada
来源
BMC UROLOGY | 2016年 / 16卷
关键词
Point-of-care; Prostate cancer; Prostate specific antigen; CANCER PATIENTS; TOTAL PSA; HYPERPLASIA; MEN; PREDICTOR; RELAPSE; VOLUME; BLOOD; RISK;
D O I
10.1186/s12894-016-0119-9
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Measurement of the prostate specific antigen (PSA) remains an important tool in prostate cancer (PC) diagnosis. Due to limited availability of laboratory devices in an outpatient setting, compact and easy-to-handle point-of-care (POC) systems are desirable. Recently, a chip for PSA measurement on the concile (R) Omega 100 POC reader platform was introduced. To investigate the clinical applicability, we evaluated the system in a consecutive cohort of patients undergoing PSA measurement in our outpatient clinic. Methods: Between 07/2014 and 01/2015, PSA was analyzed in a total of 198 patients by the POC reader system and in parallel by an Immulite 2000 (R) and Centaur (R) standard laboratory system, respectively. By standard (Immulite (R)) measurement, 67 (34,2 %) had PSA > 4 ng/ml and 131 (65,8 %) had PSA = 4 ng/ml. Results were correlated by linear regression analyses for all patients and within PSA subgroups. For patients with available prostate histology after PSA measurement (n = 68), receiver-operating characteristic curves were created and area under the curve (AUC), sensitivity and specificity for the prediction of PC at best cut-off value were calculated. Results: The coefficients of determination (r(2)) for the POC device compared to laboratory testing were 0.72 (Immulite (R)) and 0.63 (Centaur (R)), respectively (both p < 0.0001). In the PSA range of = 4 ng/ml, the observed correlations were 0.75 and 0.70, respectively. For the POC test system, AUC for detection of PC was calculated with 0.745 while the standard laboratory tests showed 0.778 (Immulite (R)) and 0.771 (Centaur (R)). At best cut-off of 3.64 ng/ml, PSA analysis by the POC system showed a sensitivity of 85.7 % and a specificity of 66.7 %. Conclusions: The POC system obtained good concordance to elaborate laboratory measurement. In a screening scenario, the system provides quick and reliable PSA measurement, especially in the PSA range up to 4 ng/ml.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Assessment of a new point-of-care system for detection of prostate specific antigen
    Steffen Rausch
    Joerg Hennenlotter
    Josef Wiesenreiter
    Andrea Hohneder
    Julian Heinkele
    Christian Schwentner
    Arnulf Stenzl
    Tilman Todenhöfer
    BMC Urology, 16
  • [2] Point-of-care fluorescence immunoassay for prostate specific antigen
    Oh, Sang Wook
    Kim, Young Min
    Kim, Hyun Jeong
    Kim, Sung Joong
    Cho, Jin-Sun
    Choi, Eui Yul
    CLINICA CHIMICA ACTA, 2009, 406 (1-2) : 18 - 22
  • [3] Shrink polymer based electrochemical sensor for point-of-care detection of prostate-specific antigen
    He, Wenzheng
    Liu, Liying
    Cao, Zeyuan
    Lin, Yang
    Tian, Yuxin
    Zhang, Qifu
    Zhou, Changdong
    Ye, Xiongying
    Cui, Tianhong
    BIOSENSORS & BIOELECTRONICS, 2023, 228
  • [4] Enhanced Immunosensor Using a Handheld pH Meter for the Point-of-care, Sensitive Detection of Prostate Specific Antigen
    Gao, Rong
    Liu, Bingqian
    Luo, Dajuan
    Su, Yonghuan
    Su, Lixia
    ELECTROANALYSIS, 2022, 34 (02) : 275 - 280
  • [5] Highly sensitive sensing detection of prostate-specific antigen based on point-of-care electrochemical immunosensor
    Liu, Yang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2023, 18 (03):
  • [6] Advanced nanoengineered—customized point-of-care tools for prostate-specific antigen
    Arshid Numan
    Sima Singh
    Yiqiang Zhan
    Lijie Li
    Mohammad Khalid
    Kirsi Rilla
    Sanjeev Ranjan
    Stefano Cinti
    Microchimica Acta, 2022, 189
  • [7] Advanced nanoengineered-customized point-of-care tools for prostate-specific antigen
    Numan, Arshid
    Singh, Sima
    Zhan, Yiqiang
    Li, Lijie
    Khalid, Mohammad
    Rilla, Kirsi
    Ranjan, Sanjeev
    Cinti, Stefano
    MICROCHIMICA ACTA, 2022, 189 (01)
  • [8] Point-of-Care Prostate Specific Antigen Testing: Examining Translational Progress toward Clinical Implementation
    Garg, Saweta
    Sachdeva, Ashwin
    Peeters, Marloes
    McClements, Jake
    ACS SENSORS, 2023, 8 (10) : 3643 - 3658
  • [9] An Ultra-Rapid Biosensory Point-of-Care (POC) Assay for Prostate-Specific Antigen (PSA) Detection in Human Serum
    Mavrikou, Sophie
    Moschopoulou, Georgia
    Zafeirakis, Athanasios
    Kalogeropoulou, Konstantina
    Giannakos, Georgios
    Skevis, Athanasios
    Kintzios, Spyridon
    SENSORS, 2018, 18 (11)
  • [10] Antigen detection as a point-of-care test for TB: the case of lipoarabinomannan
    Swaminathan, Soumya
    Rekha, V. V. Banu
    FUTURE MICROBIOLOGY, 2012, 7 (05) : 559 - 564