Correction of solar irradiation effects on air temperature measurement using a dual-thermistor radiosonde at low temperature and low pressure

被引:6
|
作者
Lee, Sang-Wook [1 ]
Park, Eun Uk [1 ,2 ]
Choi, Byung Il [1 ]
Kim, Jong Chul [1 ]
Woo, Sang-Bong [1 ]
Park, Seongchong [1 ]
Yang, Seung Gu [3 ]
Kim, Yong-Gyoo [1 ]
机构
[1] Korea Res Inst Stand & Sci, Div Phys Metrol, Gajeong Ro 267, Daejeon 34113, South Korea
[2] Hanbat Natl Univ, Dept Elect, Daejeon, South Korea
[3] Jinyang Ind, Meteorol Environm Res Ctr, Ansung, South Korea
关键词
temperature correction; solar irradiation; dual thermistors; low temperature; radiosonde; air temperature metrology; RADIATION ERRORS;
D O I
10.1002/met.1690
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The correction of heat-biased temperatures measured by radiosondes during the daytime is affected by other environmental parameters such as ventilation, air temperature and pressure. Among them, the effect of low temperature on temperature sensors under irradiation is not well known. This paper studies the combined effect of low temperature and low pressure on the air-temperature measurement under irradiation to obtain a correction formula using dual thermistors with different emissivities. The temperature variation of both thermistors under irradiation (about 1500Wm(-2)) is increased as temperature and pressure are decreased from 25 to -80 degrees C and from 1000 to 10hPa, respectively. The observed behaviour is explained using heat-transfer equations. In order to calculate the irradiance with no pyranometer, the temperature difference between dual thermistors is formulated as a function of irradiance, temperature and pressure through chamber-based experiments. After the relationship between parameters is established, the temperature difference between thermistors is solely used to calculate the irradiance. The uncertainty of the calculated irradiance using dual thermistors is 6.2% (94Wm(-2)) at the coverage factor k=1. The calculated irradiance is used for the correction of the heat-biased temperatures measured by the thermistors. The combined uncertainty of corrected temperature is 0.79K (k=1), which includes uncertainties owing to the irradiance, pressure and temperature sensors as well as modelling. The dual thermistor-based technique using ground-calibration facilities can provide the traceability to the International System of Units (SI) in the measurement of irradiance and temperature in the upper air.
引用
收藏
页码:283 / 291
页数:9
相关论文
共 50 条
  • [21] TEMPERATURE EFFECTS ON FLOW OF LOW PRESSURE GAS
    HERB, RG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1965, 36 (03): : 367 - &
  • [22] NEUTRON IRRADIATION EFFECTS AT LOW TEMPERATURE CU AND AL
    MCREYNOLDS, AW
    AUGUSTYNIAK, W
    MCKEOWN, M
    ROSENBLATT, DB
    PHYSICAL REVIEW, 1954, 94 (05): : 1417 - 1417
  • [23] Low-temperature irradiation effects in lithium orthosilicates
    Feldbach, E.
    Kotlov, A.
    Kudryavtseva, I.
    Liblik, P.
    Lushchik, A.
    Maaroos, A.
    Martinson, I.
    Nagirnyi, V.
    Vasil'chenko, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 250 (1-2 SPEC. ISS.): : 159 - 163
  • [24] LOW-TEMPERATURE REACTOR IRRADIATION EFFECTS IN METALS
    BLEWITT, TH
    COLTMAN, RR
    KLABUNDE, CE
    NOGGLE, TS
    JOURNAL OF APPLIED PHYSICS, 1957, 28 (06) : 639 - 644
  • [25] Low temperature measurement using fluorescence thermometry
    Miyazaki, Yukari
    Aizawa, Hiroaki
    Katsumata, Toru
    Komuro, Shuji
    2008 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS, VOLS 1-4, 2008, : 896 - 899
  • [26] A SOLAR COLLECTOR AND A COGENERATOR FOR LOW-TEMPERATURE AIR HEATING
    RIVA, G
    MAZZETTO, F
    ENERGY IN AGRICULTURE, 1985, 4 (04): : 285 - 304
  • [27] Compensation of solar radiation and ventilation effects on the temperature measurement of radiosondes using dual thermistors
    Lee, Sang-Wook
    Park, Eun Uk
    Choi, Byung Il
    Kim, Jong Chul
    Woo, Sang-Bong
    Kang, Woong
    Park, Seongchong
    Yang, Seung Gu
    Kim, Yong-Gyoo
    METEOROLOGICAL APPLICATIONS, 2018, 25 (02) : 209 - 216
  • [28] Minimizing material damage using low temperature irradiation
    Craven, E.
    Hasanain, F.
    Winters, M.
    RADIATION PHYSICS AND CHEMISTRY, 2012, 81 (08) : 1254 - 1258
  • [29] Effects of injection pressure and timing on low load low temperature gasoline combustion using LES
    O'Donnell, Patrick C.
    Lawler, Benjamin
    Lopez-Pintor, Dario
    Sofianopoulos, Aimilios
    APPLIED THERMAL ENGINEERING, 2023, 232
  • [30] Temperature correction of PSP measurement for low-speed flow using infrared camera
    Wind Tunnel Technology Center, Institute of Space Technology and Aeronautics, Japan Aerospace Exploration Agency, 7-44-1, Jindaijihigashi-Machi, Chofu-Shi, Tokyo, 182-8522, Japan
    The Asian Office of Aerospace Research and Development, AOARD; Sendai Tourism and Convention Bureau; American Institute of Aeronautics and Astronautics, AIAA; The Japan Society for Aeronautical and Space Sciences, JSASS; Japan Aerospace Exploration Agency, JAXA, 1600, 214-220 (2005):