The selection of the method to quantify glycerol largely depends on the amount present in the sample, the matrix nature where glycerol has to be determined, and the potential interferences accompanying the analyte. We compared different electrochemical methods to determine glycerol in terms of convenience, from the point of view of the sample nature, the time spent to accomplish the analysis, the preferably use of green consumables, the limit of detection (LD), and the operational cost. We studied two alternative methodologies based on amperometric measurements to determine glycerol. In aqueous media, we use the versatile gold electrode, being the linear range 2.5 x 10(-5) to 2.0 x 10(-3) M, and the LD 10 mu M (3 x SDb, standard deviation of the blank). In extremely complex matrixes, where many electroactive species are expected to be present, we propose to use a new approach based on biosensor technology, which takes advantage of an inexpensive, soluble redox mediator, and uses only one enzyme with its cofactor in solution. The substrate was a glassy carbon paste electrode; the system used the enzyme glycerol dehydrogenase, soluble NAD(+) as cofactor, and ferricyanide as charge mediator. The response showed to be linear between 7.0 x 10 (5) and 1.8 x 10 (3) M, and the LD was 20 mu M. The biosensor displayed more than two month stability without the enzyme losing activity when kept dried at 4 degrees C. The time taken to complete the analysis was 10min, counting from the moment the sample was taken until the signal was recorded. The operational cost of the whole analysis was less than that derived of using other biosensors or a spectrophotometric assay. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:142 / 148
页数:7
相关论文
共 50 条
  • [21] APPLICATION OF LOW-COST ROAD ACCIDENT COUNTERMEASURES ACCORDING TO AN AREA-WIDE STRATEGY.
    Dalby, E.
    Ward, Heather
    Traffic Engineering and Control, 1981, 22 (11): : 567 - 574
  • [22] Low-Cost Phase-Selective Organogelators for Rapid Gelation of Crude Oils at Room Temperature
    Ren, Changliang
    Chen, Feng
    Zhou, Feng
    Shen, Jie
    Su, Haibin
    Zeng, Huaqiang
    LANGMUIR, 2016, 32 (50) : 13510 - 13516
  • [23] Pump-free and low-cost negative pressure sampling device for rapid sample loading in MCE
    Hu, Hongmei
    Yin, Xuefeng
    Qi, Liya
    Liu, Jinhua
    ELECTROPHORESIS, 2009, 30 (24) : 4213 - 4218
  • [24] Low-Cost and Nature-Friendly Hierarchical Porous Carbon for Enhanced Capacitive Electrochemical Energy Storage
    Chu, Dawei
    Nashalian, Ardo
    Zhou, Yihao
    Zhao, Xun
    Guo, Dongxuan
    He, Ranran
    Chen, Weiwen
    Chen, Jun
    ACS APPLIED ENERGY MATERIALS, 2020, 3 (08): : 7246 - 7250
  • [25] Voltammetry and Related Electrochemical Methods Based on Low-Cost Instrumentation: a Review from Basic to Advanced
    Vilaso-Cadre, Javier Ernesto
    Reyes-Dominguez, Ivan Alejandro
    Gonzalez-Fontanet, Javier Gonzalo
    Hidalgo-Viteri, Juan
    Gonzalez-Fernandez, Lazaro Adrian
    Arada-Perez, Maria de los angeles
    Turdean, Graziella Liana
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (05) : 520 - 539
  • [26] Voltammetry and Related Electrochemical Methods Based on Low-Cost Instrumentation: a Review from Basic to Advanced
    Vilasó-Cadre, Javier Ernesto
    Reyes-Domínguez, Iván Alejandro
    González-Fontanet, Javier Gonzalo
    Hidalgo-Viteri, Juan
    González-Fernández, Lázaro Adrián
    los Ángeles Arada-Pérez, María de
    Turdean, Graziella Liana
    Journal of Analytical Chemistry, 1600, 79 (05): : 520 - 539
  • [27] Rapid and low-cost fabrication of thermoelectric composite using low-pressure cold pressing and thermocuring methods
    Shi, Jianxu
    Chen, Hualing
    Jia, Shuhai
    Wang, Wanjun
    MATERIALS LETTERS, 2018, 212 : 299 - 302
  • [28] Rapid and accurate detection of herpes simplex virus type 2 using a low-cost electrochemical biosensor
    de Lima, Lucas F.
    Ferreira, Andre L.
    Awasthi, Sita
    Torres, Marcelo D. T.
    Friedman, Harvey M.
    Cohen, Gary H.
    de Araujo, William R.
    de la Fuente-Nunez, Cesar
    CELL REPORTS PHYSICAL SCIENCE, 2023, 4 (09):
  • [29] Opportunities for using two low-cost methods for treatment of metal bearing aqueous streams
    Gaydardjiev, S
    Hadjihristova, M
    Tichy, R
    MINERALS ENGINEERING, 1996, 9 (09) : 947 - 964
  • [30] A Low-Cost Inkjet-Printed Aptamer-Based Electrochemical Biosensor for the Selective Detection of Lysozyme
    Khan, Niazul Islam
    Maddaus, Alec G.
    Song, Edward
    BIOSENSORS-BASEL, 2018, 8 (01):