Performance of an over/under voltage relay at non-sinusoidal conditions

被引:0
|
作者
Gencer, Omer Ozgur [1 ]
Ozturk, Semra [1 ]
Karaarslan, Korhan [1 ]
机构
[1] Kocaeli Univ, Fac Engn, Dept Elect Engn, Veziroglu Yerleskesi,Eski Golcuk Yolu, Kocaeli, Turkey
关键词
D O I
10.1109/MELCON.2006.1653292
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The effects of non-sinusoidal voltages on the performance of an over/under voltage relay were experimentally studied. The frequency and amplitude of individual harmonics were adjusted with a programmable power source and the operating times of the relay are examined. The relation between the harmonic voltages and relay behavior is determined. The measurements show that the relay may operate slower or faster than expected when distorted voltages have third harmonic component.
引用
收藏
页码:1102 / 1105
页数:4
相关论文
共 50 条
  • [41] Visualizing Power Quantities under Non-Sinusoidal and Time-Varying Conditions
    Carvalho, T. C. O.
    Duque, C. A.
    Silveira, P. M.
    Severo Mendes, M. A.
    Ribeiro, P. F.
    2014 IEEE 16TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2014, : 757 - 761
  • [42] Modelling of the Power Factor for AC Linear Circuits under Non-sinusoidal Conditions
    Andrei, Horia
    Spinei, Fanica
    Cepisca, Costin
    Andrei, Paul C.
    Vasile, Nicolae
    MELECON 2010: THE 15TH IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, 2010, : 353 - 358
  • [43] A genetic based algorithm for power quality measurement under non-sinusoidal conditions
    Al-Hasawi, WM
    El-Naggar, KM
    Proceedings of the Fourth IASTED International Conference on Power and Energy Systems, 2004, : 169 - 174
  • [44] Third-order passive load identification under non-sinusoidal conditions
    Tenti, P
    Mattavelli, P
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2002, 12 (02): : 93 - 100
  • [45] Reactive power in linear electrical networks under periodic non-sinusoidal conditions
    Kens, Yu.A.
    Zhurakhovskij, A.V.
    Elektrichestvo, 1998, (08): : 55 - 62
  • [46] Some remarks concerning the measurement of the ferromagnetic losses under non-sinusoidal conditions
    Tugulea, A
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2002, 12 (02): : 85 - 92
  • [47] Series Hybrid Active Power Filter for Mitigating Voltage Unbalance and Harmonics under Unbalanced Non-Sinusoidal Supply Conditions
    Mulla, M. A.
    Chudamani, R.
    Chowdhury, A.
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2012, : 671 - 676
  • [48] An evaluation of non-sinusoidal tariff schemes towards a regulatory tariff system for non-sinusoidal power system conditions
    Bezuidenhout, SL
    Rens, APJ
    2004 IEEE AFRICON: 7TH AFRICON CONFERENCE IN AFRICA, VOLS 1 AND 2: TECHNOLOGY INNOVATION, 2004, : 637 - 643
  • [49] Derating of transformers under non-sinusoidal loads
    Sadati, S. B.
    Tahani, A.
    Jafari, M.
    Dargahi, M.
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT, VOL I, 2008, : 263 - 268
  • [50] Evaluation of Metrological Performance of Electromagnetic Current Measurement Transformers in Non-Sinusoidal Conditions
    Gallo, Daniele
    Landi, Carmine
    Luiso, Mario
    2014 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2014, : 671 - 674