Performance of an over/under voltage relay at non-sinusoidal conditions

被引:0
|
作者
Gencer, Omer Ozgur [1 ]
Ozturk, Semra [1 ]
Karaarslan, Korhan [1 ]
机构
[1] Kocaeli Univ, Fac Engn, Dept Elect Engn, Veziroglu Yerleskesi,Eski Golcuk Yolu, Kocaeli, Turkey
关键词
D O I
10.1109/MELCON.2006.1653292
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The effects of non-sinusoidal voltages on the performance of an over/under voltage relay were experimentally studied. The frequency and amplitude of individual harmonics were adjusted with a programmable power source and the operating times of the relay are examined. The relation between the harmonic voltages and relay behavior is determined. The measurements show that the relay may operate slower or faster than expected when distorted voltages have third harmonic component.
引用
收藏
页码:1102 / 1105
页数:4
相关论文
共 50 条
  • [1] Evaluation of Over/Under Voltage Relay at Non-sinusoidal Conditions
    Inan, E.
    Sengul, M.
    Alboyaci, B.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2008, 3 (04): : 668 - 672
  • [2] On the Behavior of LED Lamps Under Non-Sinusoidal Voltage Conditions
    Peretto, Lorenzo
    Tinarelli, Roberto
    Rovati, Luigi
    Bernabei, Mario
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 779 - 784
  • [3] Impacts on Power Factor of AC Voltage Controllers Under Non-Sinusoidal Conditions
    Mahar, Mukhtiar Ahmed
    Larik, Abdul Sattar
    Shah, Syed Asif Ali
    MEHRAN UNIVERSITY RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY, 2012, 31 (02) : 297 - 300
  • [4] An update on the performance of reactive energy meters under non-sinusoidal conditions
    Guilherme L. Xavier
    Gabriel Miyasaka
    Eduardo T. Silvério
    Hélio Rubens J. da Silva
    Lara L. Braz
    Raphael F. B. de Oliveira
    Rodrigo N. C. Lima
    José Rubens Macedo
    Electrical Engineering, 2020, 102 : 1881 - 1891
  • [5] An update on the performance of active energy meters under non-sinusoidal conditions
    Macedo Jr, Jose Rubens
    Xavier, Guilherme L.
    Gondin, Isaque N.
    Oliveira, Lincoln T. S.
    de Oliveira, Raphael F. B.
    ELECTRICAL ENGINEERING, 2020, 102 (03) : 1785 - 1794
  • [6] Performance Analysis of Active Energy Meters Under Non-Sinusoidal Conditions
    Xavier, G.
    Macedo Jr, J.
    de Oliveira, R.
    Oliveira, L.
    Gondim, I
    IEEE LATIN AMERICA TRANSACTIONS, 2020, 18 (04) : 808 - 815
  • [7] An update on the performance of reactive energy meters under non-sinusoidal conditions
    Xavier, Guilherme L.
    Miyasaka, Gabriel
    Silverio, Eduardo T.
    da Silva, Helio Rubens J.
    Braz, Lara L.
    de Oliveira, Raphael F. B.
    Lima, Rodrigo N. C.
    Macedo Jr, Jose Rubens
    ELECTRICAL ENGINEERING, 2020, 102 (04) : 1881 - 1891
  • [8] An update on the performance of active energy meters under non-sinusoidal conditions
    Jose Rubens Macedo
    Guilherme L. Xavier
    Isaque N. Gondin
    Lincoln T. S. Oliveira
    Raphael F. B. de Oliveira
    Electrical Engineering, 2020, 102 : 1785 - 1794
  • [9] A novel technique for optimising the harmonics and reactive power under non-sinusoidal voltage conditions
    George, S
    Agarwal, V
    IECON-2002: PROCEEDINGS OF THE 2002 28TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 2002, : 858 - 863
  • [10] The Current and Voltage Detection Under Non-sinusoidal and Unbalanced Voltage Condition
    Zhang, Xiaobin
    Zhang, Pan
    Cheng, Siyu
    Duan, Liandong
    Zhang, Hui
    2014 INTERNATIONAL ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2014, : 794 - 799