Covalent organic frameworks with tunable pore sizes enhanced solid-phase microextraction direct ionization mass spectrometry for ultrasensitive and rapid analysis of tetrabromobisphenol A derivatives

被引:30
|
作者
Gao, Wei [1 ]
Li, Guoliang [3 ,4 ]
Liu, Huan [2 ]
Tian, Yong [2 ]
Li, Wei-Tao [1 ]
Fa, Yun [2 ]
Cai, Yaqi [4 ]
Zhao, Zongshan [2 ,3 ]
Yu, Yong-Liang [1 ]
Qu, Guangbo [4 ]
Jiang, Guibin [4 ]
机构
[1] Northeastern Univ, Coll Sci, Dept Chem, Res Ctr Analyt Sci, Shenyang 110819, Peoples R China
[2] Chinese Acad Sci, Qingdao Inst Bioenergy & Bioproc Technol, CAS Key Lab Biobased Mat, Qingdao 266101, Peoples R China
[3] Qingdao Univ, Coll Environm Sci & Engn, Qingdao 266071, Peoples R China
[4] Chinese Acad Sci, State Key Lab Environm Chem & Ecotoxicol, Res Ctr Ecoenvironm Sci, Beijing 100085, Peoples R China
基金
中国国家自然科学基金;
关键词
Environmental analysis; COFS; Sample preparation; Ambient ionization mass spectrometry; Emerging organic contaminants; PERFORMANCE LIQUID-CHROMATOGRAPHY; A/S;
D O I
10.1016/j.scitotenv.2020.144388
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Selective adsorption via the size matching effect is one of the most effective strategies for separating and analyzing low levels of organic molecules. Herein, multicomponent covalent organic frameworks (MC-COFs) with tunable pore sizes are constructed by using one knot (1,3,5-triformylphloroglucinol, Tp) and two organic linkers (p-phenylenediamine, Pa; benzidine, BD). The pore sizes of the MC-COFs composed of TpPaBD(x) (X = [BD]/([Pa] + [BD]) x 100 = 0, 25, 50, 75, and 100) range from 0.5-1.5 to 0.5-2.2 nm due to variations in the initial organic linker ratios. When coupling TpPaBDx-based solid-phase microextraction (SPME) with constant flow desorption ionization mass spectrometry (CFDI-MS), these MC-COFs feature better selective adsorption performance for tetrabromobisphenol A (TBBPA) derivatives than TpPa with a smaller pore size, TpBD with a larger pore size and even some commercial fibers (e.g., polydimethylsiloxane/divinylbenzene (PDMS/DVB)-, polyacrylate (PA)- and PDMS-coated fibers). The improved method involving MC-COF TpPaBD(50) also presents favorable stability with relative standard deviations (RSD, 1 mu g L-1) for single fibers of 5.5-7.9% (n = 7) and fiberto-fiber of 6.6-7.8% (n = 7). Due to the decreased limits of detection and quantification (0.5-12 and 1.6-40 ng L-1), and reduced separation and detection time (7 min), ultratrace levels of TBBPA derivatives in real water samples are successfully detected. The proposed method shows great potential for the rapid tracing of the distribution, transportation and transformation of TBBPA derivatives to better understand their ecotoxicological effects in environmental media. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Rapid and sensitive analysis of progesterone by solid-phase extraction with amino-functionalized metal-organic frameworks coupled to direct analysis in real-time mass spectrometry
    Linnan Li
    Yilin Chen
    Yuangui Yang
    Ying Yang
    Li Yang
    Zhengtao Wang
    Analytical and Bioanalytical Chemistry, 2020, 412 : 2939 - 2947
  • [32] Rapid and sensitive analysis of progesterone by solid-phase extraction with amino-functionalized metal-organic frameworks coupled to direct analysis in real-time mass spectrometry
    Li, Linnan
    Chen, Yilin
    Yang, Yuangui
    Yang, Ying
    Yang, Li
    Wang, Zhengtao
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (12) : 2939 - 2947
  • [33] Ultra-rapid non-equilibrium solid-phase microextraction at elevated temperatures and direct coupling to mass spectrometry for the analysis of lidocaine in urine
    van Hout, MWJ
    Jas, V
    Niederländer, HAG
    de Zeeuw, RA
    de Jong, GJ
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (17): : 1563 - 1568
  • [34] Hydrophilic Chitosan/Covalent Organic Framework Composites for Efficient Solid-Phase Microextraction of Polar Phenolic Compounds Prior to Gas Chromatography: Mass Spectrometry Analysis
    Tao, Haijuan
    Liu, Jiale
    Guo, Weikang
    Shuai, Qin
    Huang, Lijin
    JOURNAL OF ANALYSIS AND TESTING, 2024, 8 (04) : 441 - 450
  • [35] Enhanced microfluidic open interface for the direct coupling of solid phase microextraction with liquid electron ionization-tandem mass spectrometry
    Marittimo, Nicole
    Famiglini, Giorgio
    Palma, Pierangela
    Arigo, Adriana
    Cappiello, Achille
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1681
  • [36] Development of solid-phase microextraction followed by gas chromatography-mass spectrometry for rapid analysis of volatile organic chemicals in mainstream cigarette smoke
    Ye, Qing
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (02) : 239 - 244
  • [37] Direct immersion solid-phase microextraction combined with ambient ionization tandem mass spectrometry to rapidly distinguish pesticides in serum for emergency diagnostics
    Su, Hung
    Lin, Hsin-Hua
    Su, Lin-Jhen
    Lin, Chia-Chen
    Jiang, Zong-Han
    Chen, Shiang-Jin
    Shiea, Jentaie
    Lee, Chi-Wei
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2022, 30 (01) : 26 - 37
  • [38] Solid-phase microextraction combined with surface-enhanced laser desorption/ionization introduction for ion mobility spectrometry and mass spectrometry using polypyrrole coatings
    Wang, Y
    Walles, M
    Thomson, B
    Nacson, S
    Pawliszyn, J
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (02) : 157 - 162
  • [39] Solid-phase microextraction and gas chromatography–mass spectrometry for analysis of phenols and nitrophenols in rainwater, as their t-butyldimethylsilyl derivatives
    Farouk Jaber
    Claude Schummer
    Jamal Al Chami
    Philippe Mirabel
    Maurice Millet
    Analytical and Bioanalytical Chemistry, 2007, 387 : 2527 - 2535
  • [40] Rapid white truffle headspace analysis by proton transfer reaction mass spectrometry and comparison with solid-phase microextraction coupled with gas chromatography/mass spectrometry
    Aprea, Eugenio
    Biasioli, Franco
    Carlin, Silvia
    Versini, Giuseppe
    Maerk, Tilmann D.
    Gasperi, Flavia
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (16) : 2564 - 2572