Source apportionment of aerosol particles using polycapillary slightly focusing X-ray lens

被引:7
|
作者
Sun, Tianxi [1 ,2 ,3 ]
Liu, Zhiguo [1 ,2 ,3 ]
Zhu, Guanghua [1 ,2 ,3 ]
Liu, Hui [1 ,2 ,3 ]
Ma, Yongzhong [5 ]
Xu, Qing [4 ]
Li, Yude [1 ,2 ,3 ]
Wang, Guangpu [1 ,2 ,3 ]
Luo, Ping [1 ,2 ,3 ]
Pan, Qiuli [1 ,2 ,3 ]
Ding, Xunliang [1 ,2 ,3 ]
机构
[1] Beijing Normal Univ, Key Lab Beam Technol & Mat Modificat, Minist Educ, Beijing 100875, Peoples R China
[2] Beijing Normal Univ, Inst Low Energy Nucl Phys, Beijing 100875, Peoples R China
[3] Beijing Radiat Ctr, Beijing 100875, Peoples R China
[4] Chinese Acad Sci, Inst High Energy Phys, Beijing 100039, Peoples R China
[5] Ctr Dis Control & Prevent Beijing, Beijing 100013, Peoples R China
基金
高等学校博士学科点专项科研基金;
关键词
Micro-XRF; Capillary X-ray optics; Single aerosol particle analysis; Source apportionment; FLUORESCENCE; MICROSCOPE;
D O I
10.1016/j.nima.2009.01.009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A micro-X-ray fluorescence (Micro-XRF) spectrometer based on a polycapillary Slightly focusing X-ray lens (PSFXRL) and laboratory X-ray source was designed to carry out the Source apportionment of aerosol particles. In the distribution curve of the X-ray intensity in the focal spot of PSFXRL, there was a plateau with a diameter of about 65 mu m. The uniformity of this plateau was about 3%. This was helpful in measuring the XRF spectrum of a single aerosol particle in which the element distributions are not uniform. The minimum detection limit (MDL) of this Micro-XRF spectrometer was 15 ppm for the Fe-K-alpha. The origins of the aerosol particles at the exit of a subway station and a construction site were apportioned. This Micro-XRF spectrometer has potential applications in analysis of single aerosol particles. (C) 2009 Published by Elsevier B.V.
引用
收藏
页码:755 / 759
页数:5
相关论文
共 50 条
  • [21] Simulation of X-Ray transmitted in the square polycapillary X-ray lens
    Peng, Shiqi
    Liu, Zhiguo
    Sun, Tianxi
    Wang, Kai
    Yi, Longtao
    Yang, Kui
    Chen, Man
    Wang, Jinbang
    SELECTED PAPERS OF THE PHOTOELECTRONIC TECHNOLOGY COMMITTEE CONFERENCES HELD NOVEMBER 2015, 2016, 9796
  • [22] X-Ray Fluorescence Computed Tomography With Polycapillary Focusing
    Cong, Wenxiang
    Xi, Yan
    Wang, Ge
    IEEE ACCESS, 2014, 2 : 1138 - 1142
  • [23] Size-Resolved Source Apportionment of Aerosol Particles with a Confocal Micro X-Ray Fluorescence Spectrometer
    Sun, Tianxi
    Liu, Zhiguo
    Li, Yude
    Ma, Yongzhong
    Wang, Guangfu
    Zhu, Guanghua
    Xu, Qing
    Lin, Xiaoyan
    Luo, Ping
    Pan, Qiuli
    Liu, Hui
    Teng, Yuepeng
    Ding, Xunliang
    APPLIED SPECTROSCOPY, 2011, 65 (12) : 1398 - 1402
  • [24] X-RAY ANALYTICAL MICROSCOPE WITH KUMAKHOV'S X-RAY POLYCAPILLARY LENS
    Borisov, G. I.
    Ermak, M. G.
    Zhmylev, S. I.
    Odinov, V. D.
    Poukhov, A. V.
    Malagodi, D.
    Srinivasan, S.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C73 - C73
  • [25] Development of a new total reflection X-ray fluorescence instrument using polycapillary X-ray lens
    Nakano, K.
    Tanaka, K.
    Ding, X.
    Tsuji, K.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (10-11) : 1105 - 1109
  • [26] A new film analysis method using polycapillary X-ray lens
    Yang, Jun
    Ding, Xunliang
    Liang, Changlin
    APPLIED SURFACE SCIENCE, 2007, 253 (20) : 8352 - 8355
  • [27] Study on the measurement of properties of polycapillary X-ray lens
    Sun, TX
    Ding, XL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 226 (04): : 651 - 658
  • [28] Performances of synchrotron radiation microbeam focused by monolithic half focusing polycapillary X-ray lens
    Sun, Tianxi
    Liu, Zhiguo
    He, Bo
    Wei, Shiqiang
    Xie, Yaning
    Liu, Tao
    Hu, Tiandou
    Ding, Xunliang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (02): : 285 - 288
  • [29] The application of polycapillary X-ray lens in XRF microanalysis
    Yan, YM
    Ding, XL
    Pan, QL
    He, YJ
    MICROBEAM ANALYSIS 2000, PROCEEDINGS, 2000, (165): : 137 - 138
  • [30] Monochromatic X-ray imaging using a combination of doubly curved crystal and polycapillary X-ray lens
    Sun, Tianxi
    MacDonald, C. A.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (02) : 141 - 146