Automatic Brachial Ankle Pulse Wave Velocity Measurements for Vascular Damage Assessments

被引:0
|
作者
Gonzalez, R. [1 ,2 ]
Morales, O. [2 ]
Delgado, J. [2 ]
Padilla, J. M. [2 ]
Ferrero, J. M. [1 ]
Saiz, J. [1 ]
机构
[1] Univ Politecn Valencia, Inst Invest & Innovac Bioingn, E-46071 Valencia, Spain
[2] Inst Technol Morelia, Morelia, Michoacan, Mexico
关键词
D O I
10.1109/CIC.2008.4749005
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
An automatic brachial ankle pulse wave velocity device was developed using plethysmographic method based on blood pressure cuffs wrapped on arm brachial artery and tibial artery Of ankle. Three electrodes of electrocardiogram were placed on ventral surface of both wrists and medial side of right ankle. The acquired signals of volume pulse and ECG were displayed The pulse transit time between brachium and ankle was calculated as the time difference between maximal time derivative points and foot-to-foot pulse waves originated by the same QRS complex. A study was carried out with 39 people, 22 healthy volunteers and 17 patients with diagnosed cardiovascular diseases. A t-tested distributions of brachial ankle pulse wave velocity were performed. They showed that using maximal time derivative is more accurate than foot-to-foot pulse wave both in patients with cardiovacular disease and in healthy volunteers.
引用
收藏
页码:173 / +
页数:2
相关论文
共 50 条
  • [21] The Association Between Ankle Brachial Pressure Index and Pulse Wave Velocity: Clinical Implication of Pulse Wave Velocity
    Khandanpour, Nader
    Armon, Matthew P.
    Jennings, Barbara
    Clark, Allan
    Meyer, Felicity J.
    ANGIOLOGY, 2009, 60 (06) : 732 - 738
  • [22] Central pulse wave velocity is responsible for increased brachial-ankle pulse wave velocity in subclinical hypothyroidism
    Nagasaki, Toshiki
    Inaba, Masaaki
    Kumeda, Yasuro
    Hiura, Yoshikazu
    Yamada, Shinsuke
    Shirakawa, Kumi
    Ishimura, Eiji
    Nishizawa, Yoshiki
    CLINICAL ENDOCRINOLOGY, 2007, 66 (02) : 304 - 308
  • [23] Brachial-ankle pulse wave velocity in Japanese university students
    Shiotani, A
    Motoyama, M
    Matsuda, T
    Miyanishi, T
    INTERNAL MEDICINE, 2005, 44 (07) : 696 - 701
  • [24] Characteristics of brachial-ankle pulse wave velocity in Japanese children
    Niboshi, Ayumi
    Hamaoka, Kenji
    Sakata, Koichi
    Inoue, Fumio
    EUROPEAN JOURNAL OF PEDIATRICS, 2006, 165 (09) : 625 - 629
  • [25] Brachial Ankle Pulse Wave Velocity: A Classic but Still Important Method
    Hayashi, Hideki
    Fujita, Masatoshi
    INTERNAL MEDICINE, 2013, 52 (01) : 3 - 4
  • [26] Influence of Metabolic Syndrome on Brachial-Ankle Pulse Wave Velocity
    Han, Ah-Reum
    Kim, Jung-Ha
    Lee, Duk-Chul
    KOREAN JOURNAL OF FAMILY MEDICINE, 2007, 28 (04): : 271 - 277
  • [27] Comparison of brachial-ankle pulse wave velocity in Japanese and Russians
    Liu, HJ
    Yambe, T
    Zhang, XM
    Saijo, Y
    Shiraishi, Y
    Sekine, K
    Maruyama, M
    Kovalev, YA
    Milyagina, IA
    Milyagin, VA
    Nitta, S
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2005, 207 (04): : 263 - 270
  • [28] Pulse wave velocity and ankle brachial index in patients with Kawasaki disease
    Ooyanagi, R
    Fuse, S
    Tomita, H
    Takamuro, M
    Horita, N
    Mori, M
    Tsutsumi, H
    PEDIATRICS INTERNATIONAL, 2004, 46 (04) : 398 - 402
  • [29] The effect of measurement position on brachial-ankle pulse wave velocity
    Shimawaki, Satoshi
    Toda, Mai
    Nakabayashi, Masataka
    Sakai, Naotaka
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2015, 17 (01) : 111 - 116
  • [30] The Relationships of Brachial-Ankle Pulse Wave Velocity with Central Obesity
    Shim, Kyung Won
    Kim, Jung Hyun
    Lee, Hong Soo
    Lee, Sang Hwa
    OBESITY, 2008, 16 : S135 - S135