Automatic Brachial Ankle Pulse Wave Velocity Measurements for Vascular Damage Assessments

被引:0
|
作者
Gonzalez, R. [1 ,2 ]
Morales, O. [2 ]
Delgado, J. [2 ]
Padilla, J. M. [2 ]
Ferrero, J. M. [1 ]
Saiz, J. [1 ]
机构
[1] Univ Politecn Valencia, Inst Invest & Innovac Bioingn, E-46071 Valencia, Spain
[2] Inst Technol Morelia, Morelia, Michoacan, Mexico
关键词
D O I
10.1109/CIC.2008.4749005
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
An automatic brachial ankle pulse wave velocity device was developed using plethysmographic method based on blood pressure cuffs wrapped on arm brachial artery and tibial artery Of ankle. Three electrodes of electrocardiogram were placed on ventral surface of both wrists and medial side of right ankle. The acquired signals of volume pulse and ECG were displayed The pulse transit time between brachium and ankle was calculated as the time difference between maximal time derivative points and foot-to-foot pulse waves originated by the same QRS complex. A study was carried out with 39 people, 22 healthy volunteers and 17 patients with diagnosed cardiovascular diseases. A t-tested distributions of brachial ankle pulse wave velocity were performed. They showed that using maximal time derivative is more accurate than foot-to-foot pulse wave both in patients with cardiovacular disease and in healthy volunteers.
引用
收藏
页码:173 / +
页数:2
相关论文
共 50 条
  • [1] Brachial-ankle pulse wave velocity as a marker of atherosclerotic vascular damage and cardiovascular risk
    Yamashina, A
    Tomiyama, H
    Arai, T
    Hirose, K
    Koji, Y
    Hirayama, Y
    Yamamoto, Y
    Hori, S
    HYPERTENSION RESEARCH, 2003, 26 (08) : 615 - 622
  • [2] Brachial-ankle pulse wave velocity
    Shimizu, H
    INTERNAL MEDICINE, 2005, 44 (07) : 688 - 689
  • [3] The brachial-ankle pulse wave velocity
    Safar, Michel E.
    O'Rourke, Michael F.
    JOURNAL OF HYPERTENSION, 2009, 27 (10) : 1960 - 1961
  • [4] Brachial-ankle pulse wave velocity, cardio-ankle vascular index, and prognosis
    Ato, Dai
    VASCULAR HEALTH AND RISK MANAGEMENT, 2018, 14 : 321 - 348
  • [5] Utility of automated brachial ankle pulse wave velocity measurements in hypertensive patients
    Munakata, M
    Ito, N
    Nunokawa, T
    Yoshinaga, K
    AMERICAN JOURNAL OF HYPERTENSION, 2003, 16 (08) : 653 - 657
  • [6] Automatic or manual arterial path for the ankle-brachial differences pulse wave velocity
    Sanchez Munoz-Torrero, Juan Francisco
    Fernando Calderon-Garcia, Julian
    De Nicolas-Jimenez, Jorge Manuel
    Garcia-Ortiz, Luis
    Rodilla-Salas, Enrique
    Angel Gomez-Marcos, Manuel
    Suarez-Fernandez, Carmen
    Cordovilla-Guardia, Sergio
    Rico-Martin, Sergio
    PLOS ONE, 2018, 13 (11):
  • [7] Brachial-ankle pulse wave velocity and microalbuminuria
    Nakamura, Yoshio
    Makin, Hirofumi
    HYPERTENSION RESEARCH, 2006, 29 (07) : 469 - 470
  • [8] Pitfalls in the ankle-brachial index and brachial-ankle pulse wave velocity
    Ato, Dai
    VASCULAR HEALTH AND RISK MANAGEMENT, 2018, 14 : 41 - 62
  • [9] Comparison of Atherosclerotic Indicators Between Cardio Ankle Vascular Index and Brachial Ankle Pulse Wave Velocity
    Horinaka, Shigeo
    Yabe, Akihisa
    Yagi, Hiroshi
    Ishimura, Kimihiko
    Hara, Hitoshi
    Iemua, Tomoyuki
    Matsuoka, Hiroaki
    ANGIOLOGY, 2009, 60 (04) : 468 - 476
  • [10] Ankle-brachial index and pulse wave velocity
    Mohler, Emile R.
    JOURNAL OF HYPERTENSION, 2006, 24 : 418 - 418