Performance evaluation of different types of ground source heat exchangers in a hot and dry climate

被引:3
|
作者
Majeed, Saif H. [1 ]
Abdul-Zahra, Amar S. [1 ]
Mutasher, Dheya G. [1 ]
机构
[1] Univ Technol Iraq, Mech Engn Dept, Al Sinaa St,POB 19006, Baghdad, Iraq
关键词
3U-tubes; coil tubes; ground energy source; heat exchanger; thermal performance; THERMAL PERFORMANCE; PUMP SYSTEM; ENERGY; PIPE;
D O I
10.1002/htj.22566
中图分类号
O414.1 [热力学];
学科分类号
摘要
Most of the energy consumption in a hot and dry area is used for the air-conditioning systems. This study aims to investigate the possibility of reducing the electricity consumption in air conditioners using ground cold energy to cool the hot fluid in the pipes. Several experiments were carried out to investigate the performance of the proposed system to be used in the weather conditions of Baghdad city (i.e., hot and dry). Two configurations of ground source heat exchangers (GSHEs) were developed and constructed. The first configuration comprised coil type with two different materials (copper and polyvinyl chloride [PVC]). The second configuration was the 3U type, which was made from copper, PVC, and galvanized. Three water flow rates were considered (5, 10, and 15 L/min) with water inlet temperatures (80 degrees C, 70 degrees C, and 60 degrees C). The experiments' results showed that the type of material of the pipe has a significant influence on both the heat transfer effectiveness and the system performance. Copper tubes were the best type of heat exchanger (type coil) to be used in this regard. The highest recorded values of the heat exchange rate were 5.81, 4.81, 2.72, 1.60, and 1.32 kW with an inlet temperature of 80 degrees C and a flow rate of 5 L/min for the case of copper coil, copper 3U, galvanized 3U, PVC profile, and PVC 3U, respectively. These findings can be used as a guideline for future studies of GSHEs, particularly for the applications fixed in unsaturated soils.
引用
收藏
页码:5700 / 5722
页数:23
相关论文
共 50 条
  • [21] Development of a dry mortar with nanosilica and different types of industrial waste for the application in borehole heat exchangers
    Castan-Fernandez, C.
    Marcos-Robredo, G.
    Castro-Garcia, M. P.
    Rey-Ronco, M. A.
    Alonso-Sanchez, T.
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 359
  • [22] Evaluation of the performance of a ground-source heat-pump system with series GHE (ground heat exchanger) in the cold climate region
    Bakirci, Kadir
    ENERGY, 2010, 35 (07) : 3088 - 3096
  • [23] A simulation-based analysis of variable flow pumping in ground source heat pump systems with different types of borehole heat exchangers: A case study
    Zarrella, Angelo
    Emmi, Giuseppe
    De Carli, Michele
    ENERGY CONVERSION AND MANAGEMENT, 2017, 131 : 135 - 150
  • [24] STUDY ON HEAT TRANSFER PERFORMANCE OF GROUND HEAT EXCHANGERS WITH DIFFERENT PIPES CONSIDERING LAYERED STRATUM
    Zhang, Yuanyan
    Tao, Xiu
    Chen, Mou
    Xia, Chenyu
    Xie, Haiyan
    Chen, Feizhou
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (10): : 764 - 770
  • [25] HEAT-EXCHANGERS - TYPES, PERFORMANCE AND APPLICATIONS
    SCACCIA, C
    THEOCLITUS, G
    CHEMICAL ENGINEERING, 1980, 87 (20) : 121 - 132
  • [26] Evaluation of polyethylene and steel heat exchangers of ground source heat pump systems based on seasonal performance comparison and life cycle assessment
    Ren, Chen
    Deng, Yelin
    Cao, Shi-Jie
    ENERGY AND BUILDINGS, 2018, 162 : 54 - 64
  • [27] The effectiveness of ground source heat exchangers for sustainable cooling in commercial Buildings: A comprehensive evaluation
    Farag, Ahmed
    Emam, Mohamed
    Ookawara, Shinichi
    Nada, Sameh
    APPLIED THERMAL ENGINEERING, 2025, 262
  • [28] Prediction of the thermal performance of horizontal-coupled ground-source heat exchangers
    Wu, Yupeng
    Gan, Guohui
    Gonzalez, Raquel Garcia
    Verhoef, Anne
    Vidale, Pier Luigi
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2011, 6 (04) : 261 - 269
  • [29] Thermo-economic analysis of four different types of ground heat exchangers in energy piles
    Luo, Jin
    Zhao, Haifeng
    Gui, Shuqiang
    Xiang, Wei
    Rohn, Joachim
    Blum, Philipp
    APPLIED THERMAL ENGINEERING, 2016, 108 : 11 - 19
  • [30] Analysis of ground source heat pumps with horizontal ground heat exchangers for northern Japan
    Tarnawski, V. R.
    Leong, W. H.
    Momose, T.
    Hamada, Y.
    RENEWABLE ENERGY, 2009, 34 (01) : 127 - 134