Pressurized ion chamber for low energy radiation monitoring

被引:2
|
作者
Prasad, KR
Balagi, V
Dighe, PM
Alex, M
Karpagam, R
机构
[1] Electronics Division, Bhabha Atomic Research Centre
关键词
D O I
10.1016/S1350-4487(97)00019-X
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Ion chambers that can respond to gamma energies as low as 35 keV have been developed for environmental and area monitoring for low energy X-ray background a: the rotating anode X-ray generator facility and other accelerators at CAT, Indore. They are expected to measure exposure levels ranging from 10 mu r/h to 100 mr/h. These chambers have an all-welded aluminium construction and pressurized nitrogen filling. Explosion welded SS-AI clad material has been used for the welding of SS-to-alumina insulators. Out of the two ion chambers developed. the environmental ion chamber has a 25 1 sensitive volume filled at 85 psi and detects radiation exposure levels from 10 mu r/h to 10 mr/h. The 800 cc area monitor ion chamber filled at 120 psi can be used from 10 mr/h to 10 r/h with a portable survey instrument. These chambers have an energy response between 35 keV and 1.25 MeV that is uniform within +/-9%. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:593 / 598
页数:6
相关论文
共 50 条
  • [31] Minimizing radiation damage in silicon structured with low energy focused ion beams
    Nebiker, PW
    Dobeli, M
    Muhle, R
    Suter, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 127 : 897 - 900
  • [32] ULTRADIPOLE RADIATION FROM LOW-ENERGY HEAVY-ION REACTIONS
    KICINSKAHABIOR, M
    SNOVER, KA
    MAJ, A
    DREBI, Z
    YE, D
    KELLY, M
    ACTA PHYSICA POLONICA B, 1995, 26 (2-3): : 439 - 451
  • [33] LOW-TEMPERATURE ENERGY-RELEASE IN PLATINUM AFTER ION RADIATION
    JACKSON, JJ
    PHYSICAL REVIEW B, 1975, 12 (04): : 1217 - 1227
  • [34] OPTICAL RADIATION FROM LOW-ENERGY ION-SURFACE COLLISIONS
    WHITE, CW
    TOLK, NH
    PHYSICAL REVIEW LETTERS, 1971, 26 (09) : 486 - &
  • [35] BEHAVIOUR OF A FURNACE WORKING IN A PRESSURIZED CHAMBER
    VIDAL, D
    LALLEMAN.G
    LACAM, A
    REVUE GENERALE DE THERMIQUE, 1966, 5 (60): : 1235 - &
  • [36] A pressurized chamber for muon experiments with helium
    Krasnoperov, EP
    Herlach, D
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1996, 39 (01) : 150 - 152
  • [37] OBSERVATIONS OF POGO ION CHAMBER EXPERIMENT IN OUTER RADIATION ZONE
    ANDERSON, HR
    HUDSON, PD
    MCCOY, JE
    JOURNAL OF GEOPHYSICAL RESEARCH, 1968, 73 (19): : 6285 - +
  • [38] ESTIMATION OF THE RESPONSE OF ION-CHAMBER DETECTORS TO BETA RADIATION
    SISK, DR
    SWINTH, KL
    RADIATION PROTECTION DOSIMETRY, 1991, 37 (01) : 25 - 29
  • [39] ENERGY RESPONSE MEASUREMENTS OF AIR-FILLED ION-CHAMBER USING THE HOMOGENEOUS ION-CHAMBER
    KOBAYASHI, H
    SASAKI, A
    ODA, N
    JOURNAL OF RADIATION RESEARCH, 1981, 22 (01) : 76 - 76
  • [40] STREAMER CHAMBER FOR LOW-ENERGY APPLICATIONS
    RICEEVAN.P
    MISHRA, SR
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1971, 4 (SEP): : 638 - &