Measurement and imaging of birefringent axis by phase resolved polarization sensitive optical coherence tomography

被引:0
|
作者
Hitzenberger, CK [1 ]
Götzinger, E [1 ]
Sticker, M [1 ]
Fercher, AF [1 ]
机构
[1] Univ Vienna, Inst Med Phys, A-1010 Vienna, Austria
关键词
optical coherence tomography; polarization sensitive OCT; polarization; phase measurement;
D O I
10.1117/12.470473
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present a modified method of polarization sensitive optical coherence tomography (PS-OCT) that measures backscattered intensity, birefringence, and fast optic axis orientation with only one single A-scan per transverse measurement location. The technique employs a standard two-channel PS-OCT setup in combination with a phase sensitive recording of the interferometric signals in the two orthogonally polarized detection channels. We use a Hilbert transform based algorithm to extract amplitude and phase information contained in the interferometric signals. While the birefringence information is obtained from the signal amplitudes, as usual in PS-OCT, a careful analysis of the propagating beams by the Jones calculus reveals, that the information on the fast axis orientation is encoded entirely in the phase difference of the interferometric signals. We demonstrate our method and report on accuracy and precision of birefringence and fast axis measurements in a transparent technical object. Finally, we present PS-OCT maps of birefringence and of fast axis orientation recorded in scattering tissue.
引用
收藏
页码:120 / 127
页数:8
相关论文
共 50 条
  • [21] Polarization sensitive optical coherence tomography for imaging of biological tissues
    Chen, Xiaodong
    Wang, Yi
    Li, Wanhui
    Yu, Daoyin
    FOURTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, PTS 1 AND 2, 2006, 6047
  • [22] Mapping local retardance in birefringent samples using polarization sensitive optical coherence tomography
    Fan, Chuanmao
    Yao, Gang
    OPTICS LETTERS, 2012, 37 (09) : 1415 - 1417
  • [23] Polarization sensitive optical coherence tomography with single input for imaging depth-resolved collagen organizations
    Tang, Peijun
    Kirby, Mitchell A.
    Le, Nhan
    Li, Yuandong
    Zeinstra, Nicole
    Lu, G. Nina
    Murry, Charles E.
    Zheng, Ying
    Wang, Ruikang K.
    LIGHT-SCIENCE & APPLICATIONS, 2021, 10 (01)
  • [24] Polarization sensitive optical coherence tomography with single input for imaging depth-resolved collagen organizations
    Peijun Tang
    Mitchell A. Kirby
    Nhan Le
    Yuandong Li
    Nicole Zeinstra
    G. Nina Lu
    Charles E. Murry
    Ying Zheng
    Ruikang K. Wang
    Light: Science & Applications, 10
  • [25] Birefringence properties of normal human cornea imaged by phase resolved polarization sensitive optical coherence tomography
    Hitzenberger, CK
    Götzinger, E
    Pircher, M
    Sticker, M
    Fercher, AF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U298 - U298
  • [26] Correcting Optical-Axis Calculation in Polarization-Sensitive Optical Coherence Tomography
    Fan, Chuanmao
    Yao, Gang
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (10) : 2556 - 2559
  • [27] Analysis of birefringent image in the retinal nerve fiber layer by polarization sensitive optical coherence tomography
    Park, J
    Kemp, NJ
    Zaatari, HN
    Milner, TE
    Rylander, HG
    OPHTHALMIC TECHNOLOGIES XIV, 2004, 5314 : 188 - 194
  • [28] Imaging thermally damaged tissue by polarization sensitive optical coherence tomography
    de Boer, JF
    Srinivas, SM
    Malekafzali, A
    Chen, ZP
    Nelson, JS
    OPTICS EXPRESS, 1998, 3 (06): : 212 - 218
  • [29] Endobronchial polarization sensitive optical coherence tomography for airway wall imaging
    Vassileva, Sofi
    Wijsman, Pieta C.
    Soldati, Tatiana
    Vaselli, Margherita
    Goorsenberg, Annika W. M.
    De Bruin, Daniel M.
    De Boer, Johannes F.
    Annema, Jouke T.
    Bonta, Peter I.
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [30] Imaging the primate retina using polarization sensitive optical coherence tomography
    Marsack, J
    Ducros, M
    Parekh, S
    Thomsen, S
    Rylander, HG
    Milner, TE
    OPHTHALMIC TECHNOLOGIES XI, 2001, 4245 : 158 - 163